Investigation of rebar corrosion in plain and steel fiber reinforced concrete under flexural loading

Lifli ve lifsiz betonarme yapı elemanlarında eğilme yükü altında donatı korozyonunun incelenmesi

  1. Tez No: 301679
  2. Yazar: AHMET ONUR PEHLİVAN
  3. Danışmanlar: PROF. TURAN ÖZTURAN, YRD. DOÇ. DR. NİLÜFER ÖZYURT ZİHNİOĞLU
  4. Tez Türü: Yüksek Lisans
  5. Konular: İnşaat Mühendisliği, Civil Engineering
  6. Anahtar Kelimeler: Beton, Eğilme, Korozyon, Çatlak, Çatlak büyüme, Çatlak oluşumu, Çelik lif, Concrete, Bending, Corrosion, Crack, Crack growth, Crack formation, Steel fiber
  7. Yıl: 2011
  8. Dil: İngilizce
  9. Üniversite: Boğaziçi Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: İnşaat Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Donatıların korozyonu betonarme yapılarda erken bozulmaya yol açması ve ömrünü azaltması sebebiyle betonarme yapıların dayanıklılığında en temel etkenlerden biridir. Kodlarda özellikle beton kalitesi ve beton örtüsü kalınlığının donatının korozyondan korunmasında etkili olduğu belirtilmiştir. Birçok sebepten dolayı çatlaklar oluşabilir ve bu çatlaklar klorür iyonlarının yüksek kaliteli ve kalın beton örtülü betonlarda dahi betonun içine sızmasına yol açabilir. Betona çelik liflerin eklenmesinin betonun mukavemetine etkisi çok bilindik iken korozyon üzerindeki etkisi hakkında bilgiler limitlidir. Bu araştırma çatlaklı ve çatlaksız iki su-çimento oranı (0.45 ve 0.65), iki beton örtüsü kalınlığı (25 mm ve 45 mm), lifli ve lifsiz olmak üzere sekiz çeşit kiriş numunelerin yarı hücre potansiyellerinin ve korozyon hızlarının karşılaştırmalarının sonuçlarını incelemektedir. Üç noktadan eğilme yüklemesi yapılarak 0.4 mm kritik çatlak genişliği oluşturulmuş ve sıkıştırma sistemiyle oluşturulan çatlaklar sabitlenmiştir. Numuneler NaCl çözeltisi kullanılarak ıslak-kuru çevrimlere maruz bırakılmış ve her çevrimin sonunda yarı-hücre potansiyeli ve korozyon hızı ölçümleri alınmıştır. Çevrimler sekiz ay boyunca sürdürülmüştür. Sonuçlar 0.4 mm çatlak genişliğinin dışarıdan gelen zararlı maddelerin hızlı girişine ve dolayısıyla hızlı korozyon başlangıcına ve ilerlemesine sebep olduğunu göstermiştir. Su-çimento oranı ve beton örtüsü kalınlığının korozyonu etkileyen diğer önemli faktörler olduğu gözlemlenmiştir. Lif etkisi incelenmiş fakat kesin bir sonuca varılamamıştır, ancak yüksek kaliteli betonda liflerin yararlı olduğu görülmüştür. Çatlaksız numunelerde, beton örtüsü kalınlığının önemi çatlaklı numunelere göre daha belirgin olurken, su-çimento oranı ise hem çatlaksız hem çatlaklı numunelerde belirleyici olmuştur.

Özet (Çeviri)

Corrosion of rebars is one of the main causes of poor durability for RC structures as it induces an early deterioration of concrete structures and reduces their service life. Codes state the importance of concrete quality and cover thickness to protect the reinforcement from corrosion. However, as a result of many reasons, cracks can occur unavoidably and chlorides can penetrate even through high-quality concretes and greater concrete cover thicknesses. Addition of steel fibers definitely improves mechanical strength of concrete but knowledge on its contribution on corrosion is limited. This research discusses the relationship between the half-cell potentials and corrosion rates of cracked and uncracked concrete beams with a single deformed bar with two water-to-cement ratios (0.45, 0.65), two different concrete cover thicknesses (25 mm, 45 mm) and with or without fibers. Three point flexural tests were conducted to generate crack widths of 0.4 mm as the critical crack width on the specimens and these cracks were stabilized by a bolt system. The specimens were subjected to wetting-drying cycles by using NaCl solution and in the end of each cycle half-cell potential and corrosion rate measurements were taken and continued for eight months. Results showed that 0.4 mm crack width caused quick ingress of aggressive agents into the cracked specimens and shorter corrosion initiation period and quicker corrosion propagation. Water-to-cement ratio and concrete cover thickness were also found to be other significant parameters that affect corrosion. Fiber presence was investigated deeply but a conclusive comment could not be made, but for higher quality concretes fibers seemed useful. For uncracked specimens, effect of concrete cover thickness was more evident with respect to cracked specimens where water-to-cement ratio was important for both states.

Benzer Tezler

  1. Investigation of rebar corrosion in plain and steel fiber reinforced concrete under static and dynamic loading

    Lifli ve lifsiz betonarme yapı elemanlarında statik ve dinamik yük altında donatı korozyonunun incelenmesi

    ANIL NİŞ

    Yüksek Lisans

    İngilizce

    İngilizce

    2011

    Boğaziçi Üniversitesi

    İnşaat Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  2. Nano silika-mikro silika içeren normal ve yüksek dayanımlı betonlarda donatı-beton aderans özelliklerinin incelenmesi

    Investigation of reinforcement-concrete bond properties in normal and high strength concrete containing nano silica and/or micro silica

    BÜŞRA BOYACI

    Yüksek Lisans

    Türkçe

    Türkçe

    2022

    İstanbul Teknik Üniversitesi

    İnşaat Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  3. İzmir'de bazı yolların kapatılarak yaya bölgeleri oluşturma da kent peyzajını geliştirme açısından yeniden planlanması üzerinde araştırmalar

    Başlık çevirisi yok

    BAHAR TÜRKYILMAZ

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Şehir ve Bölge Planlama Ana Bilim Dalı

    Yükleniyor...

  4. Kuyruk modelleri ve analizi üzerine bir uygulama

    Başlık çevirisi yok

    DİDEM ÖZPULAT

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Bilgisayar Bilimleri ve Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  5. Samsun ve çevresinde tarla sarmaşığı (conuolvulus arvensis L.)'na karşı biyolojik savaşa esas olacak fauna tespiti

    Investigations on the insect fauna of the field binweed (Conuolvulus arvensis L.) related to its biological control in Samsun Province

    YASEMİN UFUK GERMAN

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Bitki Koruma Ana Bilim Dalı

    Yükleniyor...