Geri Dön

Su örneklerinde nitrat ve nitrit iyonlarının elektrokimyasal akış enjeksiyon analiz yöntemi ile tayini ve kemometrik hesaplamalar

The determination of nitrate and nitrite ions in water samples electrochemical flow injection analysis method and chemometric calculations

  1. Tez No: 316331
  2. Yazar: HİLAL EREN
  3. Danışmanlar: PROF. DR. MÜBERRA ANDAÇ
  4. Tez Türü: Doktora
  5. Konular: Kimya, Chemistry
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2012
  8. Dil: Türkçe
  9. Üniversite: Ondokuz Mayıs Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Kimya Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 198

Özet

Çalışmada; tümüyle katı-kontakt PVC-membran nitrat, nitrit, klorür ve genel anyon seçici elektrotlar hazırlandı. Elektrotların durgun ve hareketli ortamlarda potansiyometrik performans özellikleri test edildi. Nitrat, nitrit, klorür ve genel anyon seçici elektrotlar kullanılarak sensör dizileri hazırlandı. Hareketli ortam ölçümleri için düşük ölü hacme sahip akış hücreleri tasarlandı. Hazırlanan akış hücreleri hareketli ortamda dedektör olarak kullanılarak çevre suyu örneklerindeki nitrat, nitrit ve klorür anyonlarının eş zamanlı analizi yapıldı.Sensör dizilerinin durgun ve hareketli ortamlardaki doğrusal ve doğrusal olmayan çok değişkenli kalibrasyonları kemometrik hesaplamalarla gerçekleştirildi. Hesaplamalarda, deneysel tasarıma göre hazırlanan anyon karışımı çözeltilerindeki anyon derişimleri ve bu çözeltilere karşılık elektrotlardan okunan potansiyel değerleri ve pik yükseklikleri kullanıldı. Sensör dizilerinin çok değişkenli doğrusal kalibrasyonları için Çoklu Doğrusal Regresyon (MLR), Temel Bileşenler Regresyonu (PCR) ve Kısmi En Küçük Kareler Regresyonu (PLS) metotları; doğrusal olmayan kalibrasyonları için Yapay Sinir Ağları (ANN) kullanıldı. Elde edilen çok değişkenli kalibrasyon modelleri karşılaştırılarak en iyi tahmin gücüne sahip kalibrasyon modelleri belirlendi. Hareketli ortamda, standart referans çözeltilerin ölçümleri için en iyi model kullanılarak elde edilen sonuçlar klasik kalibrasyonla elde edilen sonuçlarla karşılaştırıldı. Sertifikalı referans çözeltilerin nitrat ve nitrit miktarları için hesaplanan %hata değerlerinin kemometrik yöntemlerin kullanılmasıyla nitrat için %64'den %14'e, nitrit için %29'dan %14'e düştüğü belirlendi.

Özet (Çeviri)

In the study, all solid-state PVC-membrane nitrate, nitrite, chloride and general anion selective electrodes were prepared. Potentiometric performance characteristics of the electrodes were tested in steady state and flow through conditions. Sensor arrays were developed by using prepared electrodes. The low dead volume flow through cells were designed and used as a dedector in flow injection analysis measurements for the simultaneous determination of nitrate, nitrite, chloride ions in water samples.Linear and non-linear calibrations of the sensor arrays in steady state and flow through conditions were realized by chemometric calculations.The anion concentrations in the anion mixtures which were prepared according to the experimental design and the potential values and peak heights obtained from the electrodes versus these anion mixtures were used in calculations as input data. For the multivariate linear calibrations of the sensor arrays, Multiple Linear Regression (MLR), Principle Component Regression (PCR) and Partial-Least-Squares Regression (PLS) methods and for the non-linear calibrations of the sensor arrays Artificial Neural Networks (ANN) method were used. The multivariate calibration models which have the best prediction power were determined by comparing the obtained multivariate calibration models with each other. The analysis results obtained by both multivariate calibrations and classical calibration of certificated reference solutions in flow through conditions were compared each other. It was found that relative errors in determination of nitrate and nitrite ions were decreased from 64% to 14% and 29% to 14% respectively if compared to the use of a single proposed ion-selective electrodes.

Benzer Tezler

  1. Polipirolün elektrokimyasal katı-faz ekstraksiyon kolonu olarak kullanımı

    Using of polypyrrole as an electrochemical solid-phase extraction coloumn

    BETÜL ERCAN

    Yüksek Lisans

    Türkçe

    Türkçe

    2006

    KimyaAnadolu Üniversitesi

    Kimya Ana Bilim Dalı

    DOÇ. DR. YÜCEL ŞAHİN

  2. Fabrication and characterization of nickel oxide functionalized graphene oxide-polyacrylamide nanocomposites

    Nikel oksit ile fonksiyonelleşmiş grafen oksit-poliakrilamid nanokompozitin üretimi ve karakteristik özelliklerinin incelenmesi

    CUMHUR YILDIRIM

    Yüksek Lisans

    İngilizce

    İngilizce

    2016

    Kimyaİstanbul Teknik Üniversitesi

    Nanobilim ve Nanomühendislik Ana Bilim Dalı

    PROF. DR. FİGEN KADIRGAN

  3. Investigation of ammonia removal and biogas recovery following anaerobic stabilization of the chicken wastes

    Tavuk atıklarının havasız stabilizasyonu sonrasında anaerobik amonyak giderimi ve biyogaz geri kazanımının araştırılması

    GÖKŞEN PEKYAVAŞ

    Yüksek Lisans

    İngilizce

    İngilizce

    2017

    Çevre Mühendisliğiİstanbul Teknik Üniversitesi

    Çevre Mühendisliği Ana Bilim Dalı

    DOÇ. DR. ÇİĞDEM GÖMEÇ

  4. Fitoplanktonik organizmaların İkizcetepeler ve Çaygören barajlarında mevsimsel ve dikey dağılımlarının incelenmesi

    The investigation of the seasonal and vertical distribution of phytoplanktonic organisms in İkizcetepeler and Çaygören reservoirs

    TUĞBA ONGUN SEVİNDİK

    Doktora

    Türkçe

    Türkçe

    2009

    BiyolojiBalıkesir Üniversitesi

    Biyoloji Ana Bilim Dalı

    DOÇ. DR. KEMAL ÇELİK

  5. Bazı metal iyonlarının Bi(III)4-metil piperidin ditiyokarbamat ile birlikte çöktürülmesi ve ASS ile tayini

    Determination of some metal ions with ASS after Bi(III)4-methyl piperidine dithiocarmate coprecipitation

    AYŞEGÜL EFENDİOĞLU

    Yüksek Lisans

    Türkçe

    Türkçe

    2004

    KimyaOndokuz Mayıs Üniversitesi

    Kimya Ana Bilim Dalı

    PROF.DR. BEKİR BATI