Geri Dön

Kanal akışında optimize edilmiş ısı alıcılarda çarpan jetle ısı ve akış karakteristiklerinin belirlenmesi

Determination of heat and flow characteristics with impingement jet for optimized heat sinks in channel flow

  1. Tez No: 322589
  2. Yazar: ABDÜSSAMED KABAKUŞ
  3. Danışmanlar: PROF. DR. KENAN YAKUT
  4. Tez Türü: Yüksek Lisans
  5. Konular: Makine Mühendisliği, Mechanical Engineering
  6. Anahtar Kelimeler: Çarpan hava jetleri, Impinging air jets
  7. Yıl: 2012
  8. Dil: Türkçe
  9. Üniversite: Atatürk Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Makine Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Çarpan jetler soğutmanın ihtiyaç duyulduğu birçok endüstriyel uygulamada kullanılmaktadır. Gaz türbin kanatlarının soğutulması, cam temperlemesi, metallerin ısıl işlemleri, kumaş, kağıt, kereste vb. malzemelerin kurutulması ve son yıllarda teknolojinin hızla gelişmesine bağlı olarak elektronik cihazların ve mikro işlemcilerin soğutulması gibi birçok alanda kullanılmaktadır.Bu çalışmada, rüzgar tünelinde Taguchi yöntemiyle, L18(21*37) ortogonal dizisine göre, optimize edilmiş RFG-1 ve RFG-2 olarak adlandırılan dikdörtgen kanatçıklı ısı alıcılarla, HFG-2 ve HFG-3 olarak adlandırılan altıgen kanatçıklı ısı alıcıların çarpan jetle ısı ve akış karakteristikleri belirlenmiştir. İlk olarak sabit lüle çapı ve h/d mesafesinde, 6 ayrı akış hızında sıcaklık deneyleri yapılarak Nu değerleri elde edilmiş, elde edilen veriler grafiğe dökülmüş ve ısı alıcılara ait korelasyonlar elde edilmiştir. Elde edilen sonuçlar rüzgar tüneliyle yapılan deney sonuçlarıyla karşılaştırılarak birim Nu değişimi için gereken debinin kanat boyuyla değişim grafikleri çizilip yorumları yapılmıştır. Daha sonra ısı alıcı üzerinde x ve y yönündeki basınç değerleri ölçülerek basınç katsayıları (Cpx ve Cpy) hesaplanmıştır. Ayrıca sabit pompa gücünde elde edilen iyileştirme verimi için ? ? Re grafikleri çizilip sonuçlar analiz edilmiştir. Son olarak ısı alıcılar termal kamera ile görüntülenerek görüntü kaynaklı analizle ısı alıcıların üzerindeki sıcaklık dağılımı belirlenmiştir. Deneyler sonucunda çarpan jetle soğutmanın kanal akışındaki soğutmaya göre yaklaşık 2-3 kat daha iyi olduğu ve ısı taşınımının kanatçıklı yüzeyde kanatçıksız yüzeye göre yaklaşık 2-3 kat daha iyi olduğu belirlenmiştir.

Özet (Çeviri)

Impinging jets are used in many industrial applications in which refrigeration is needed. Gas turbine blade cooling, glass tempering, thermal treatment of metals, drying of materials such as cloth, paper, lumber etc. and cooling of electronic devices and microprocessors depending on the rapid improvement of the technology recently.In this study, heat and flow characteristics with impingement jet of rectangle-finned heat sinks which are named as RFG-1 and RFG-2, and hexagon-finned heat sinks which are named as HFG-2 and HFG-3, all of which have been optimized by using Taguchi method in the wind tunnel according to L18(21*37) orthogonal sequence, have been determined. Firstly, Nu values have been acquired by carrying out heat experiments at the distance of the fixed nozzle diameter and h/d, and for 6 different flow rate; the acquired data has been graphed and correlations belonging to heat sinks have been acquired. By comparing the acquired results and experiment results which was carried out with the wind tunnel, the alteration graphics of the fin height of the flow rate which is needed for unit Nu variation have been drawn and have been made interpretation. Later, pressure coefficients (Cpx and Cpy) have been calculated by evaluating the pressure values which are at the directions of x and y on the heat sink. Moreover, ? - Re graphics have been drawn and have been analyzed for the enhancement efficiency which has been acquired with constant pump power. Lastly, by scanning the heat sinks with thermal camera, the temperature distribution on the heat sinks has been determined with spectacle-induced analysis. As a result of the experiments, it is stated that cooling with impingement jet is approximately 2-3 times better than the cooling at the channel flow, and the heat transfer on the finned surface is approximately 2-3 times better than the heat transfer on the non-finned surface.

Benzer Tezler

  1. Çoklu çarpan jetle ısı transferinde ısı alıcı dizayn parametrelerinin Taguchi yönetimiyle optimizasyonu

    Optimization of heat receiver design parameters in multi-multiplier jet heat transfer by Taguchi method

    SEYİTNUR ARVASİ

    Yüksek Lisans

    Türkçe

    Türkçe

    2022

    Makine MühendisliğiVan Yüzüncü Yıl Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ ALTUĞ KARABEY

  2. Realization of transmitter and receiver clock generation units and channel switching unit in a modified analog radio relay

    Değiştirilen bir analog radyodaki verici ve alıcı saat üretimi birimleri ve kanal anahtarlama biriminin gerçekleştirilmesi

    AYHAN BÜYÜKSEMERCİ

    Yüksek Lisans

    İngilizce

    İngilizce

    1987

    Elektrik ve Elektronik MühendisliğiOrta Doğu Teknik Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    DOÇ. DR. MURAT AŞKAR

  3. Tekstil boyamacılığında atık flottede boyama imkanları üzerine araştırma

    Başlık çevirisi yok

    MEHMET YAKARTEPE

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Tekstil ve Tekstil MühendisliğiEge Üniversitesi

    Tekstil Mühendisliği Ana Bilim Dalı

    YRD. DOÇ. DR. KERİM DURAN

  4. Mikrobiyoloji laboratuvarlarında kaza nedeni oluşan enfeksiyonlar

    Başlık çevirisi yok

    ŞENAY TÜRE

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    MikrobiyolojiGazi Üniversitesi

    Kazaların Çevresel ve Teknik Araştırması Ana Bilim Dalı (disiplinlerarası)

    PROF. DR. KAZIM KURTAR

  5. İzmir ve çevresinin sivrisinek türleri (diptera, culicidae) üzerine sistematik araştırma

    Başlık çevirisi yok

    TAHSİN YAZICIOĞLU

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    ZoolojiEge Üniversitesi

    Zooloji Ana Bilim Dalı