Mini-vidaların yüklenmesiyle kemikte oluşan değişikliklerin histopatolojik, histomorfometrik, immünohistokimyasal ve tomografik değerlendirilmesi
Histopathological, histomorfometrical, immunohistochemical and tomographical evaluation of the changes in bone by loading of mini-screw
- Tez No: 329023
- Danışmanlar: PROF. DR. NİLÜFER DARENDELİLER
- Tez Türü: Doktora
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Belirtilmemiş.
- Yıl: 2012
- Dil: Türkçe
- Üniversite: Gazi Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Diş Hekimliği Bölümü
- Bilim Dalı: Ortodonti Ana Bilim Dalı
- Sayfa Sayısı: 183
Özet
Bu çalışmanın amacı tavşan tibia kemiğine yerleştirilen farklı geometri ve çaplara sahip minividalara uygulanan kuvvetlerin kemik doku üzerindeki etkilerini histopatolojik, immünohistokimyasal, histomorfometrik ve tomografik olarak değerlendirmektir.Çalışmada 18 adet erişkin erkek tavşan kullanılmıştır. Silindirik A çapı (1.5 mm) mini-vidası, konik B çapı(1.5 mm) mini-vidası, boyun kısmı sık yivli konik geometride, C çapı (1.4 mm) ve D çapı (1.6 mm) mini-vidaları tibia kemiğine yerleştirilmiştir. Deneyde mini-vidalar, tavşanların sağ tibia kemiğine yerleştirilmiştir. Mini-vidalar tork değerleri ölçülerek kemiğe yerleştirilmiştir. Mini-vidalar arasına 1 N kuvvet verecek şekilde Nikel-Titanyum yaylar bağlanmıştır. Yerleştirilen mini-vidalar 1., 3. ve 5. haftaların sonunda denekler sakrifiye edilmiştir. Mini-vidalar kemikten tork değerleri ölçülerek çıkarılmış ve histopatolojik, histomorfometrik, immunohistokimyasal (RANK ve OPG) ve tomografik değerlendirme yapılmıştır.Silindirik yapıda olan A mini-vidası 1., 3. ve 5. haftanın sonunda konik mini-vidalara (B, C ve D) göre daha geç kemik iyileşmesi göstermiş ve çıkarma tork değerleri A mini-vidasında düşük bulunmuştur. İlk haftanın sonunda B mini-vidasında RANK immünoreaktivitesi, C mini-vidasında OPG immünoreaktivitesi gözlenmiştir. Üçüncü ve beşinci haftanın sonunda B,C,D mini-vidalarında OPG immünoreaktivitesinde artış kaydedilmiştir. En iyi kemik doku iyileşmesi, osteoblastik aktivite boyun kısmında sık yivli C ve D mini-vidasında gözlenmiş ve diğer vidalara göre daha yüksek tork değerleri ile çıkarılmıştır. Çapı fazla olan D mini-vidasında C mini-vidasına göre daha yüksek çıkarma tork değerleri kaydedilmiştir.Boyun kısmı sık yivli olan konik mini-vidaların daha stabil olduğu ve çap artışının stabilizasyonu arttırdığı kaydedilmiştir.
Özet (Çeviri)
The aim of this study is histopathological, immunohistochemical, histomorphometrical and mikro-tomographical evaluation of the changes observed in the rabbit tibia bone by the application of mini-screws with different geometry and diameter.In this study eighteen adult male rabbits are used. Cylindrical mini-screws of diameter 1.5 mm (designated as A), conical mini-screws of diameter 1.5 mm (B), conical screws of diameters 1.4 mm (C) and 1.6 mm (D) with fine-pitch threads close to screw head, were inserted in rabbit tibia. The mini-screws were inserted to the right tibia bone by recording the applied torque. Ni-Ti coil-springs that are arranged to apply 1 N force were attached between the mini-screws. The rabbits were sacrificed at the end of the 1st, 3rd and 5th weeks. Then the mini-screws were removed by measuring in the torque values and the bone has been evaluated histopathologically, histomorphometrically, immunohistochemically (RANK and OPG) and micro-tomographically.Compared with conical B, C and D mini-screws, cylindrical A mini-screws were delayed bone healing at the end of 1st, 3rd and 5th weeks and removal torque values of A mini-screws were found lower. At the end of the first week RANK immunoreactivity in B mini-screws and OPG immunoreactivity in C mini-screws were observed. At the end of 3rd and 5th weeks an increase in OPG immunoreactivity were recorded in the bone for the cases where B, C, D mini-screws have been applied. Best bone healing and osteoblastic activity were observed in the bone by the use of C and D mini-screws and higher removal torque values were also recorded for these cases. D mini-screws with wider diameter required higher removal torque values than C mini-screws.It is observed that conical with fine-pitch threads close to screw head, were more stable and it is found that stabilization increases with increasing diameter.
Benzer Tezler
- Mini vidaların, in vitro uygulama sırası ve sonrasında yüzey ve mekanik özelliklerindeki değişikliklerin ve tekrar kullanılabilirliklerinin değerlendirilmesi
In vitro evaluation of the changes in mechanical and surface characteristics and reusability of the mini screws
CİVAN AVED HERGEL
Doktora
Türkçe
2015
Diş HekimliğiMarmara ÜniversitesiOrtodonti Ana Bilim Dalı
PROF. DR. NAZAN KÜÇÜKKELEŞ
- Mini vidaların yeniden kullanımında farklı dezenfeksiyon yöntemlerinin in vitro incelenmesi
In vitro examination of different disinfection methods in the reuse of mini screws
BARIŞ KOLİK
- Farklı dizayna sahip iki ortodontik mini vidanın stabilite açısından değerlendirilmesi
Evaluation of the stability of two orthodontic mini screws with different designs
YEŞİM YASEMİN GÖLLERLİ
Diş Hekimliği Uzmanlık
Türkçe
2017
Diş HekimliğiOrdu ÜniversitesiOrtodonti Ana Bilim Dalı
YRD. DOÇ. DR. SERKAN ÖZKAN
- Ortodontik mini vidaların angulasyonunun ve gövde yapısının primer stabiliteye olan etkisi: İn vitro çalışma
Effects of insertion angle and body shape on the stability of orthodontic mini screws: iİn vitro study
CANSU DÜZGÜN
Diş Hekimliği Uzmanlık
Türkçe
2018
Diş HekimliğiÇukurova ÜniversitesiOrtodonti Ana Bilim Dalı
PROF. DR. MUSTAFA SERDAR TOROĞLU
- Ortodontik tedavi sırasında erken ve geç yüklenen mini vidaların oluk sıvısındaki interlökin-8 ve matriks metalloproteinaz-8 seviyelerinin değerlendirilmesi
Evaluation of il-8 and mmp-8 levels araound miniscrew implants loaded early and late during orthodontic tooth movement
NEJLA İLHAN