LED fotobiyomodülasyon tedavisinin dental implant stabiliteleri üzerine etkisinin değerlendirilmesi
Evaluation of the effect of LED photobiomodulation treatment on dental implant stabilities
- Tez No: 331643
- Danışmanlar: PROF. DR. HANİFE ATAOĞLU
- Tez Türü: Doktora
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Fotobiyomodülasyon, implant stabilitesi, LED, RFA, Dental implantasyon, Dental implantlar, Frekans analizi, Işık, Kemik ve kemikler, Mandibula, Osseointegrasyon, Rezonans, Implant stability, LED, Photobiomodulation, RFA, Dental implantation, Dental implants, Frequency analysis, Light, Bone and bones, Mandible, Osseointegration, Resonance
- Yıl: 2013
- Dil: Türkçe
- Üniversite: Selçuk Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Ağız, Diş ve Çene Cerrahisi Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Bu çalışmanın amacı; mandibulaya implant yerleştirilmesinden sonra ekstra-oral olarak uygulanan LED Fotobiyomodülasyon tedavisinin dental implant stabiliteleri üzerine etkisinin değerlendirilmesidir. Çalışmaya aynı çap ve uzunlukta 48 dental implant dahil edilmiştir. Tüm implantlar mandibular posterior alana yerleştirilmiştir. İmplantlar, LED tedavisi uygulanmış (n=25) deney grubu ve LED tedavisi uygulanmamış (n=23) kontrol grubu olarak iki gruba ayrılmıştır. Deney grubuna, implant yerleşimi ile aynı gün başlanmak üzere postoperatif 21 gün boyunca günde 20 dakika, OsseoPulse cihazı (Biolux Research, Kanada) kullanılarak, 625 nm dalga boyunda, 20 mW/cm2?lik enerjide LED Fotobiyomodülasyon tedavisi uygulanmıştır. İmplantların stabiliteleri; Osstell® ISQ cihazı (Osstell AB, Göteborg, İsveç) kullanılarak operasyon sırasında, postoperatif 14., 30., 60. ve 90. günlerde yapılmıştır. İstatistiksel analizler için Bağımsız Örneklem T Testi ve Eşleştirilmiş Örneklem T Testi kullanılmıştır. Çalışma sonunda, LED ile tedavi edilmiş implantlar 14. ve 30. günlerde önemli derecede daha yüksek stabilite değerleri göstermiştir (p<0,05). Operasyon anı, 60. ve 90. gün ölçümlerinde ise gruplar arasında anlamlı bir fark görülmemiştir (p>0,05). LED ile tedavi edilmiş implantlarda operasyon anında ölçülen ISQ değerleri ile 14. ve 30. günlerde ölçülen ISQ değerleri arasında istatistiksel açıdan farklılık gözlenmemiştir (p>0,05). LED ile tedavi edilmemiş implantlarda ise operasyon anında ölçülen ISQ değerleri ile 14. ve 30. günlerde ölçülen ISQ değerleri arasında fark olup (p<0,05), 14. ve 30. günlerde ölçülen ISQ değerleri operasyon anında ölçülen ISQ değerinden düşük bulunmuştur. Bu çalışmada LED ile tedavi edilmiş implantlarda operasyon anında ölçülen başlangıç ISQ değerlerinin üzerine 30. günde çıkılırken, LED ile tedavi edilmemiş implantlarda başlangıç ISQ değerlerinin üzerine 60. günde çıkılmıştır. Bu çalışmanın sonuçları; LED ile tedavi edilmiş implantların, LED ile tedavi edilmemiş implantlara göre daha hızlı stabil hale gelebileceğini ve LED tedavisinin implantların daha erken yüklenebilmesine izin verebileceğini göstermektedir.
Özet (Çeviri)
The aim of this study was to evaluate the effect of extra-oral application of LED photobiomodulation treatment on dental implant stabilities after implant placement to mandible. Forty-eight dental implants that were at the same diameter and length were included to study. All implants were placed to posterior mandible. The implants were divided into two groups; implants that received LED treatment (n=25) as test group and implants that not received LED treatment (n=23) as control group. In test group, using the OsseoPulse device (Biolux Research, Canada) at a wavelength of 625 nm, with an energy density of 20 mW/cm2, LED photobiomodulation treatment was applied for 20 minutes per day for 21 days, starting from implant placement. The implant stabilities were measured with Osstell ISQ device (Osstell AB, Göteborg, Sweden) at the time of placement and 14, 30, 60 and 90 days. Independent Samples T Test and Paired Samples T Test were used for the statistical analysis. At the end of the study, implants treated with the LED demonstrated significantly improved dental implant stability at day 14 and day 30 (p<0,05). No significant differences were seen at the time of placement, at day 60 or at day 90 between the groups (p>0,05). For the LED treated implants, there were no statistically differences between ISQ values at the time of placement and at Day 14; at the time of placement and at Day 30 (p>0,05); but for the untreated implants there were statistically differences (p<0,05); and both at Day 14 and at Day 30 ISQ values were lower than at the time of placement. At this study, mean initial ISQ values of the LED treated implants were exceed at Day 30; but, in untreated group mean initial ISQ values were exceed at Day 60. -The results of this study showed that the LED treated implants could achieve stability earlier as compared to the untreated dental implants and LED treatment could allow for earlier loading of dental implants.
Benzer Tezler
- İyileşme döneminde uygulanan LED fotobiyomodülasyon tedavisinin farklı yüzey özelliklerine sahip dental implantlarda, implant stabilite oranlarına etkisinin rezonans frekans analizi ile karşılaştırmalı olarak incelenmesi
A comparative examination of the effects of the LED photomodulation therapy on stabilities of dental implants with different surface properties as assessed by resonance frequency analysis
ÖZDE SEZGİN ÇİNKILIÇ
- İskeletsel sınıf II hastalarda twin-blok apareyi ile birlikte temporomandibular eklem bölgesine uygulanan GRR lazer ve led fotobiomodülasyon terapisinin kraniofasiyal yapılar üzerindeki etkilerinin karşılaştırılması
Comparison of the effects of GRR laser and led photobiomodulation therapy applied to the temporomandibular joint region along with twin-block appliance on craniofacial structures in skeletal class II patients
ELDAR SHEYDAYEV
- Türkiye trafik düzeninde kazaların azaltılması açısından yeni trafik kanunu uygulaması ile ilgili sorunlar ve çözüm yolları
Başlık çevirisi yok
ERDAL UÇAR
Yüksek Lisans
Türkçe
1986
Gazi ÜniversitesiKazaların Çevresel ve Teknik Araştırması Ana Bilim Dalı (disiplinlerarası)
Yükleniyor...
- A-D, D-A çeviricileri ve -40 derece ile 100 derece arasında çalışan bir dijital termometre tasarım ve yapımı
Başlık çevirisi yok
N.GÜLER FENER