Geri Dön

Küçük böbrek kitlelerinde biyopsisinin tanısal değeri

Diagnostic efficiancy of percutenous biopsy for small renal masses

  1. Tez No: 337277
  2. Yazar: TÜNKUT S. DOĞANCA
  3. Danışmanlar: PROF. DR. CAN ÖBEK
  4. Tez Türü: Tıpta Uzmanlık
  5. Konular: Üroloji, Urology
  6. Anahtar Kelimeler: Biyopsi-iğne, Böbrek, Böbrek hastalıkları, Böbrek neoplazmları, Teşhis, Teşhis teknikleri ve prosedürleri, Teşhis-ayırıcı, Biopsy-needle, Kidney, Kidney diseases, Kidney neoplasms, Diagnosis, Diagnostic techniques and procedures, Diagnosis-differential
  7. Yıl: 2011
  8. Dil: Türkçe
  9. Üniversite: İstanbul Üniversitesi
  10. Enstitü: Cerrahpaşa Tıp Fakültesi
  11. Ana Bilim Dalı: Üroloji Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Amaç: Böbrek kitlelerinden biyopsi alınması standart değildir ve özel bazı durumlarda önerilmektedir. Bu çalışmada, kliniğimizde biyopsi yapılan küçük böbrek kitlelerinde (<5cm) ameliyat sonrası patoloji ile biyopsi sonucunun histolojik uyumu karşılaştırılmış, biyopsi başarısını etkileyen faktörler irdelenmiş ve komplikasyonlar değerlendirilmiştir.Gereç ve Yöntem: Mayıs 2009 ? Ocak 2012 tarihleri arasında kliniğimize başvurmuş ve 5 cm.'den küçük böbrek kitlesi bulunan toplam 19 hastaya operasyon öncesi görüntüleme eşliğinde böbrek biyopsisi yapıldı. Biyopsi sonrası komplikasyonlar açısından takip edilen hastalar, daha sonra opere edildiler. Operasyon sonrası nihai patoloji ile biyopsi sonuçları karşılaştırıldı ve biyopsi sonuçlarına etki eden faktörler araştırıldı.Bulgular: Biyopsi sonrası 18 hastaya parsiyel nefrektomi, 1 hastaya radikal nefrektomi uygulandı. İİAB uygulanan 15 hastanın 9'unda (%69), Tru-cut biyopsi alınan 13 hastanınsa tümünde(%100) ameliyat sonrası nihai patolojileri ile biyopsi sonuçları uyumlu olarak saptandı. İİAB'nin tanısal doğruluk oranı %69, tru-cut biyopsinin ise %100 olarak hesaplandı. İİAB'nin duyarlılığı %64, özgüllüğü %100, Pozitif Prediktif Değeri(PPD) %100, Negatif Prediktif Değeri(NPD) %33 olarak hesaplandı. Tru-cut biyopsinin ise duyarlılık, özgüllük, PPD, NPD değerleri %100 olarak hesaplandı. 11 hastada (%58) biyopsiye bağlı olduğu düşünülen ve cerrahiyi zorlaştıran yapışıklıklar saptandı.Sonuç: Küçük böbrek kitlelerinin patolojisini belirlemede, güncel teknikle uygulanan böbrek biyopsisinin tanısal oranı oldukça yüksek ve komplikasyon oranı düşüktür. Yalnızca İİAB ile biyopsi, yöntemin tanısal değerini olumsuz yönde etkilemektedir. Ancak tru-cut biyopsi alınabilen durumlarda tanısal doğruluk oranı %100'e çıkmaktadır. Bu nedenle, küçük renal kitlelerde biyopsi mutlaka tru-cut kor biyopsi ile gerçekleştirilmelidir. Biyopsi sonrası oluşabilen yapışıklık cerrahiyi güçleştirebilmektedir.

Özet (Çeviri)

Introduction: There have been some historical reservations regarding the role of renal mass biopsy. In the present study, we evaluate the biopsy results, complications due to biopsy, and the correlation with the final pathology specimen of 19 patients who had surgery for their small renal masses.Patients and Method: A total of 19 patients (11 male, 8 female) underwent percutaneous biopsy of their renal mass under ultrasound guidance (fine needle and tru-cut). All patients subsequently underwent extirpative surgery; 18 partial nephrectomy and 1 radical nephrectomy. Preoperative biopsy results were compared with postoperative specimens and the complications noted.Results: Preoperative biopsy results were correlated with final pathology in 9 of 15 patients (%69) who had FNAB, and in 13 of 13 (%100) who had tru-cut core biopsy. Sensitivity, specificity, PPV and NPV?s were 64%, 100%, 100%, 33% respectively for FNAB. Sensitivity, specificity, PPV and NPV?s were all 100% for tru-cut core biopsy. There was only one complication. A perirenal hematoma was detected which resolved spontaneously under conservative therapy. In 11 patients there were adhesions due to biopsy, which caused difficulty of dissection during the operation.Conclusion: Percutenous biopsy to determine the histology of small renal masses has a high diagnostic accuracy and low complication rate. FNAB alone has a low diagnostic accuracy with false negative results. However, tru-cut core biopsy has a diagnostic accuracy of %100 . Therefore we recommend tru-cut biopsy when histopathological diagnosis is required for small renal masses.

Benzer Tezler

  1. Böbrek kitlelerinde iğne biyopsisinin tanı değeri: Radyolojik-Klinik histopatolojik uyum

    Diagnostıc accuracy of Percutan renal biopsies :Radiologic-Clinical-Hystopathologıc correlation

    BERRA AKGÜL GÜRKAN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2013

    Kocaeli Üniversitesi

    Patoloji Ana Bilim Dalı

    Yükleniyor...

  2. Landsat uydusu aracılığı ile elde edilen görüntülerin sınıflandırılmaları ve bunlara ilişkin bilgisayar programlarının hazırlanması

    Başlık çevirisi yok

    G. FERZAN KÜÇÜKA

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Bilgisayar Bilimleri ve Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  3. Dokuma kumaşlarda örgü tipinin ham kumaşın boyutları ve geometrik özellikleri üzerindeki etkilerinin araştırılması

    Başlık çevirisi yok

    EMEL ÖNDER

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Tekstil Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  4. Çocuklarda akut stres hiperglisemisinde hormonal değişikliklerin ve kısa süreli prognozun incelenmesi

    Başlık çevirisi yok

    AYGÜN DİNDAR

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1987

    İstanbul Üniversitesi

    Çocuk Sağlığı ve Hastalıkları Hemşireliği Ana Bilim Dalı

    Yükleniyor...

  5. İki katlı pamuk ipliklerinden dokunan kumaşlarda örgüye bağlı olarak maksimum atkı sıklığının değişimi üzerinde bir araştırma

    Başlık çevirisi yok

    MELTEM ASLI NARTER

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Tekstil Mühendisliği Ana Bilim Dalı

    Yükleniyor...