Geri Dön

Grafit katkılı kurşun kalemlerin geriye dönük dozimetre olarak kullanılabilirliğinin incelenmesi

Investigation of the use of graphite doped pencils as retrospective dosimeter

  1. Tez No: 352011
  2. Yazar: AYTAÇ BARIŞ
  3. Danışmanlar: DOÇ. DR. NİYAZİ MERİÇ
  4. Tez Türü: Yüksek Lisans
  5. Konular: Fizik ve Fizik Mühendisliği, Physics and Physics Engineering
  6. Anahtar Kelimeler: Geriye Dönük Dozimetri, Isıl Uyarımlı Lüminesans, Optik Uyarımlı Lüminesans, Kaza Dozimetresi, Termolüminesans, Retrospective Dosimetry, Thermoluminescence, Optical Stimulated Luminescence, Accidental Dosimeter
  7. Yıl: 2013
  8. Dil: Türkçe
  9. Üniversite: Ankara Üniversitesi
  10. Enstitü: Nükleer Bilimler Enstitüsü
  11. Ana Bilim Dalı: Medikal Fizik Ana Bilim Dalı
  12. Bilim Dalı: Sağlık Fiziği Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bugüne kadar meydana gelen radyasyon kazalarında, kaza dozunun geriye dönük olarak saptanabilmesi için çeşitli malzemelerden yararlanılmıştır. Çeşitli porselen veya seramik ev eşyaları, yapı malzemeleri, toz deterjan, ilaçlar gibi birçok malzeme bu amaçla incelenmiştir. Bu tez çalışmasında, bütün bu malzemelere ilave olarak ilk kez, kurşun kalemlerden kaza dozu saptanmaya çalışılmıştır. Oluşturulan kaza senaryosu gereği kurşun kalemlere 1 Gy kaza dozu verilmiş, ardından bu doz Optik Uyarımlı Lüminesans ve Isıl Uyarımlı Lüminesans yöntemleriyle belirlenmeye çalışılmıştır. Optik Uyarımlı Lüminesans yöntemiyle yapılan çalışmalardan istenen sonuç elde edilememiş fakat Isıl Uyarımlı Lüminesans yöntemiyle 1 Gy'lik kaza dozu iki farklı kalem için 0,98±0,20 Gy ve 0,85±0,17 Gy olarak ölçülebilmiştir. Böylece hemen her işyerinde ve çalışanların üzerinde bulunabilen kurşun kalemlerden, olası bir kaza durumunda geriye dönük doz ölçer olarak yararlanılabileceği sonucuna varılmıştır.

Özet (Çeviri)

So far, in order to determine the radiation dose retrospectively in radiation accidents, various materials have been used. Several porcelain or ceramic, household goods, construction materials, powder detergent, medicines and many other materials have been studied for this purpose. In this study, in addition to all of these materials, pencils were made to determine the dose of the accident was determined from pencils for the first time. According to the accident scenario created, pencils were irradiatied with 1 Gy radiation dose, then the given dose was measured by Optical Stimulated Luminescence (OSL) and Thermoluminescence (TL) methods. OSL method didn't give the expected results, but 1Gy accident dose was determined as 0,98±0,20Gy and 0,85±0,17Gy for two different types of pencils by TL method. Consequently, it was concluded that the pencils that carried by staff in all workplaces can be used as retrospective dosimeters in the case of radiation accidents.

Benzer Tezler

  1. Böceklerde ses çıkarma ve bunun yararları

    Sound production in insects its usefulness

    NİLGÜN MADANLAR

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Bitki Koruma Ana Bilim Dalı

    Yükleniyor...

  2. Mammografi ve ultrasonografinin meme kanseri tanısında yeri

    Başlık çevirisi yok

    CEBBAR ÇALIŞKAN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1986

    Gata

    Genel Cerrahi Ana Bilim Dalı

    Yükleniyor...

  3. Isı değiştirgeç ağlarının optimum sentezi

    Başlık çevirisi yok

    SERAP CESUR

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    Ege Üniversitesi

    Kimya Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  4. Söğüt (GD Bilecik) yöresindeki mesozoyik yaşlı tortul istifinin stratigrafisi ve sedimantolojik incelenmesi

    Stratigraphical and sedimentological investigation of the mesozoic sedimentary units of Söğüt area (se Bilecik)

    ERDOĞAN TEKİN

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    Ankara Üniversitesi

    Jeoloji Mühendisliği Ana Bilim Dalı

    Yükleniyor...