Bilgisayarlı tomografide meme dozlarının ölçülmesi ve görüntü kalitesi ile birlikte değerlendirilmesi

Measurment and evalution of breast dose together with the image quality in computed tomography

  1. Tez No: 352015
  2. Yazar: MAHMUT ANIL USLU
  3. Danışmanlar: PROF. DR. MEHMET DOĞAN BOR
  4. Tez Türü: Yüksek Lisans
  5. Konular: Fizik ve Fizik Mühendisliği, Physics and Physics Engineering
  6. Anahtar Kelimeler: CTDI, meme dozu, bilgisayarlı tomografi, ACR, hasta dozu, görüntü kalitesi, TLD, toraks fantomu, x-ışını, helikal, aksiyal, pitch, klinik protokolleri, parafin, CTDI, breast dose, computed tomography, ACR, patient dose, image quality, TLD, thorax phantom, x-rays, helical, axial, pitch, clinic protocols, paraffin
  7. Yıl: 2014
  8. Dil: Türkçe
  9. Üniversite: Ankara Üniversitesi
  10. Enstitü: Nükleer Bilimler Enstitüsü
  11. Ana Bilim Dalı: Medikal Fizik Ana Bilim Dalı
  12. Bilim Dalı: Sağlık Fiziği Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Toplumun radyasyondan etkilenmesinde, iyonlaştırıcı radyasyonun kullanıldığı medikal incelemelerin yüzdesi %48 ve bu orana en fazla katkı %24 ile bilgisayarlı tomografi incelemelerinden gelmektedir (2006, NCRP-160). Hastaların aldıkları etkin dozları birkaç mSv'ten, tarama sayısına bağlı olarak onlarca mSv'i bulabilmekte ve sonuçta hem kanser riski hem de bayan hastalar için meme dozları önemi ölçüde artmaktadır. Bu nedenle tomografik incelemelerde, en düşük hasta dozunda, optimum görüntü kalitesinin elde edilmesini sağlayacak klinik protokollerin geliştirilmesi önemlidir. Son zamanlarda kullanılmaya başlanan çok detektörlü helikal tomografi sistemlerinde kullanıcı tarafından kontrolü gereken ve hasta radyasyon dozunu etkileyen çok sayıda parametre olması en uygun klinik protokollerin seçimini daha da kritik bir hale getirmiştir. Hasta radyasyon dozlarının tomografik incelemelerde hasta üzerinde ölçülmesi, ışınlama geometrisi nedeni ile kolay değildir ve bir fantom ölçümü sonucunda elde edilen bilgisayarlı tomografi doz indeksi (CTDI), etkin dozların saptanmasında kullanılır. Ayrıca, meme yapısında bulunan ve radyasyona bağlı kanser hassasiyeti yüksek olan glandüler dokunun dozu ise farklı fantomlar ile saptanabilir.Bu tezin amacı farklı tomografik sistemlerde, meme dozlarının farklı yöntemlerle ölçülmesidir. Göğüs bölgesinin tomografik incelemeleri için meme dozlarının karşılaştırması toraks fantomunun meme aparatında gerçekleştirilmiştir. TLD ile ölçülen meme dozları ve kesit görüntülerinden hesaplanan kontrast-gürültü oranları, farklı sistemlerde radyasyon dozu-görüntü kalitesi optimizasyonunda kullanılmıştır. Glandülerite oranı ve kalınlıkları faklı olan memelerin radyasyon dozları ise değişik glandüleritede tasarımlanmış tabaka fantomlar ve farklı kalınlıklarda üretilmiş parafin fantomlar ile gerçekleştirilmiştir.

Özet (Çeviri)

Percentage of medical exposure using ionizing radiation to the public exposure is around 48% and the main contribution comes from the computed tomography (CT) examinations (NCR -1602006). The patient effective doses received in these examinations are in the order of few mSv but may reach to the orders of ten folds in case of multiple consecutive scans, causing substantial increase both for cancer risk and breast doses for female patients.Therefore, it becomes essential for the tomographic examinations to develop clinical protocols aiming to hold the patient dose at the minimum while optimizing the image quality.The selection of most appropriate clinical protocols for the multidetector helical systems used in the recent years becomes much more critique due to the presence of multiple parameters which are controlled by the user and effecting patient radiation doses. Measurements of patient radiation doses directly from the patients received in tomographic studies are not easy due to the irradiation geometry and the CTDI measured from a phantom study is used for the determination effective doses. Beside, the radiation dose to the glandular tissue of the breast which is quite sensitive to radiation induced cancer can only be measured through the use of specific phantoms.The aim of this thesis is to measure the breast doses received at different tomographic systems and clinical protocols. Comparisons of breast doses were carried out for the tomographic examinations of thoracic region using the breast fixture of a thorax phantom. Breast doses measured with TLDs and contrast to noise ratios calculated from the slice images were used for the radiation dose-image quality optimization for different systems. Radiation doses of breasts having different glandularitiy ratios and thicknesses were estimated using slabs constructed with different glandularities and paraffin phantoms produced at various thicknesses.

Benzer Tezler

  1. Diesel motorları yakıt püskürtme sistemlerinin dinamik simülasyonu

    Başlık çevirisi yok

    İRFAN KARAGÖZ

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Makine MühendisliğiUludağ Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    PROF. DR. OĞUZ BORAT

  2. Ağızlık açma mekanizmalarının tasarımı

    Başlık çevirisi yok

    RECEP EREN

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    Tekstil ve Tekstil MühendisliğiUludağ Üniversitesi

    Tekstil Mühendisliği Ana Bilim Dalı

    DOÇ. DR. HALİL R. ALPAY

  3. Doğuştan kalça çıkıklı hastalarda kalça patolojilerinin bilgisayarlı tomografi ile değerlendirilmesi

    Başlık çevirisi yok

    NECDET ŞÜKRÜ ALTUN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1987

    Ortopedi ve TravmatolojiGazi Üniversitesi

    Ortopedi ve Travmatoloji Ana Bilim Dalı

    PROF.DR. ORHAN ASLANOĞLU

  4. Kuyruk modelleri ve analizi üzerine bir uygulama

    Başlık çevirisi yok

    DİDEM ÖZPULAT

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    İstatistikEge Üniversitesi

    Bilgisayar Bilimleri ve Mühendisliği Ana Bilim Dalı

    DOÇ. DR. FİKRET İKİZ

  5. Landsat uydusu aracılığı ile elde edilen görüntülerin sınıflandırılmaları ve bunlara ilişkin bilgisayar programlarının hazırlanması

    Başlık çevirisi yok

    G. FERZAN KÜÇÜKA

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Bilgisayar Mühendisliği Bilimleri-Bilgisayar ve KontrolEge Üniversitesi

    Bilgisayar Bilimleri ve Mühendisliği Ana Bilim Dalı

    DOÇ. DR. HALİS PÜSKÜLCÜ