Geri Dön

İmplantın 'Pier abutment' olarak kullanıldığı doğal diş-implant bağlantılı sabit protetik restorasyonların biyomekanik analizi

Biomechanical analysis of tooth-implant supported fixed partial dentures when an implant serves as a pier abutment

  1. Tez No: 358941
  2. Yazar: BURCU BATAK
  3. Danışmanlar: PROF. DR. KADRİYE FUNDA AKALTAN
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Doğal diş-implant bağlantısı, rijit olmayan konnektör, biyomekanik analiz, pier abutment, sonlu eleman analizi, Tooth-implant connection, non-rigid connector, biomechanical analysis, pier abutment, finite element analysis
  7. Yıl: 2014
  8. Dil: Türkçe
  9. Üniversite: Ankara Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Diş Hekimliği Bölümü
  12. Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  13. Sayfa Sayısı: 103

Özet

Osseointegrasyon sayesinde tam ve bölümlü dişsiz çenelerin sabit ve hareketli protezlerle rehabilitasyonunda dental implantlar en önemli seçenek haline gelmiştir. İmplantların tek başına veya doğal dişlerle bağlantılı şekilde kullanılması konusunda implant ve dişin farklı mobilitelere sahip olması sistemi karmaşık hale getirir. İmplantın pier destek olarak doğal dişlerle desteklendiği sabit protetik restorasyonların biyomekanik açıdan değerlendirilmesi gerekmektedir. Çalışmamızın amacı; implantın pier desteği olarak kullanıldığı implant-diş destekli sabit restorasyonlarda, hassas bağlantının farklı konumlarda kullanılmasıyla oluşturulan rijit olmayan üst yapı tasarımlarınını, rijit ve kanatlı tasarımlarla mukayeseli olarak, 3 boyutlu sonlu elemanlar stres analiziyle değerlendirmektir. Çalışmamızda; alt çene modeli kullanılmış olup, implantın pier abutment olarak kullanıldığı 8 farklı üst yapı tasarımı (6 adet rijit olmayan, 1 adet rijit ve 1 adet kanatlı) modellenmiştir. Her bir modele dik, 30º açılı, gövdelere azaltılmış dik ve gövdelere azaltılmış açılı olmak üzere dört farklı yükleme koşulu uygulanarak, toplam 32 adet çalışma grubu oluşturulmuştur. Uygulanan kuvvetler sonucunda kortikal ve spongioz kemikte oluşan maksimum ve minimum asal gerilmeler, implant ve metal altyapı materyallerinde meydana gelen von Mises gerilme değerleri ölçülmüştür. Bununla birlikte destek dişler ve/veya implanttaki intrüzyonu değerlendirmek amacıyla vertikal (z) ve toplam (m) yer değiştirme incelenmiştir. Çalışmamızın sınırları içerisinde, elde edilen sayısal veriler sonucunda, diğer tasarımlara göre kanatlı tasarımın implant çevresinde, rijit tasarımın ise periodontal desteği molar dişe göre daha zayıf olan kanin dişte daha yüksek gerilmelere ve yer değiştirmelere neden olduğu gözlenmiştir. Hassas bağlantının implantın hem mezial hem distalinde ve implantın sadece distalinde kullanıldığı tasarımlar implant etrafındaki kemikte en uygun gerilme dağılımını oluşturmuştur.

Özet (Çeviri)

The use of dental implants has expanded over the past decades to include anterior and posterior regions of both arches in edentulous and partially edentulous patients, however the choice of using self-supporting implants or implants together with natural teeth in anatomically limited areas remains controversial. While splinting the implant and tooth is a rational alternative in some clinical situations, the dissimilar mobility patterns of the osseointegrated implants and natural teeth make the biomechanical behavior of the entire system complicated. In addition, tooth-implant supported fixed partial dentures when an implant serves as a pier abutment should be evaluated biomechanically. The aim of this study is to evaluate the stress transmission characteristics of various non-rigid connection designs performed with placing the precission attachment(s) in different locations for a tooth-implant supported fixed fartial denture when an implant serves as a pier abutment compared to a rigid and a cantilever design. In this study, mandible bone models were generated to represent 8 different prosthesis design (6 non-rigid, 1 rigid and 1 cantilever). A total number of 32 groups were prepared, each design consisting of a different loading protocol, including vertical, oblique (30º), vertical reduced force on pontics and oblique reduced force on pontics. The maximum and minimum principal stresses in cortical and spongeous bone, the von Misses stresses in the implant and metal framework as a result of the applied forces were measured. In order to evaluate the intrusion of the supporting tooth and the implant, the vertical (z) and the total (m) displacement values were calculated. Within the limitations of this study, numerical data showed that the cantilever design caused more stress and displacements around the implant and the rigid design lead to more stress around the canine tooth which has the less periodontal support than a molar tooth. The designs in which the precision attachment placed in both mesial and the distal side of the implant and only distal side of the implant generated the most favorable stress distribution around the implant.

Benzer Tezler

  1. Implantüstü protezlerde farklı materyal ve tekniklerle hazırlanmış protez alt yapılarının pasif uyumlarının sonlu elemanlar analizi ile değerlendirilmesi

    A finite element analysis: Passive fit of implant supported dentures frameworks prepared with different materials and technics

    GİZEM NUR ÖZTÜRK

    Doktora

    Türkçe

    Türkçe

    2019

    Diş Hekimliğiİstanbul Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. BELKIS GÜLSEN BAYRAKTAR

  2. Deksametazon implantın retina ven tıkanıklığına bağlı makula ödemi olgularında monoterapi ya da kombine tedavide etkinlik ve güvenirliği

    Efficacy and safety of dexamethasone implant as monotherapy or in combinationtherapy for macular edema in retinal vein occlusion

    AYŞE YAĞMUR KANRA

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2016

    Göz Hastalıklarıİstanbul Medeniyet Üniversitesi

    Göz Hastalıkları Ana Bilim Dalı

    DOÇ. DR. AYLİN ARDAGİL AKÇAKAYA

  3. Dental implantın cerrahisini takiben düşük enerjili laser uygulamasının osseointegrasyon üzerine etkisinin rezonans frekans analizi ile değerlendirilmesi

    Evaluation of the effect of low level laser therapy on osseointegration after dental implant surgery with resonance frequency analysis

    SILA ŞAHİN

    Doktora

    Türkçe

    Türkçe

    2012

    Diş HekimliğiAnkara Üniversitesi

    Ağız, Diş, Çene Hastalıkları ve Cerrahisi Ana Bilim Dalı

    PROF. DR. ÜMİT KIYMET AKAL AKTAŞ

  4. Alveolar kemik ogmentasyonunda kullanılan otojen blok greft ve demineralize blok allogreft materyalinin histomorfometrik ve klinik olarak incelenmesi

    Clinical and histomorphometrical analysis of demineralized freeze-dried cortical bone-block allografts and autogenous bone block grafts for alveolar ridge augmentation

    ELÇİN ASLAN

    Doktora

    Türkçe

    Türkçe

    2014

    Diş Hekimliğiİstanbul Üniversitesi

    Diş Hekimliği Bölümü

    PROF. DR. ZİHNİ CÜNEYT KARABUDA

  5. Dental implant cerrahisinde pre-operatif radyolojik kemik densitesi değeri ile subjektif kemik kalitesi puanlaması, yerleştirme torku ve rezonans frekans analizi arasındaki ilişkinin değerlendirilmesi

    Assessment of correlation between pre-operative radiologic bone density and subjective bone quality score, insertion torque and resonance frequency analysis in dental implant surgery

    FARİZ SALİMOV

    Doktora

    Türkçe

    Türkçe

    2014

    Diş HekimliğiÇukurova Üniversitesi

    Ağız, Diş, Çene Hastalıkları ve Cerrahisi Ana Bilim Dalı

    PROF. DR. MEHMET KÜRKCÜ