Geri Dön

Mezbaha atık su arıtım tesisinde su kalitesi parametrelerinin belirlenmesi (Balıkesir - Gönen)

Determination of water quality parameters from a waste treatment effluent (Balikesir - Gönen)

  1. Tez No: 377469
  2. Yazar: SİNAN UZUNDUMLU
  3. Danışmanlar: DOÇ. DR. YEŞİM BÜYÜKATEŞ
  4. Tez Türü: Yüksek Lisans
  5. Konular: Su Ürünleri, Aquatic Products
  6. Anahtar Kelimeler: Su Kalitesi, Besin Elementleri, Arıtma Tesisi, BOİ, KOİ, Koliform Bakteri, Water Quality, Nutrients, Treatment Facility, BOD, COD, Coliform Bacteria
  7. Yıl: 2014
  8. Dil: Türkçe
  9. Üniversite: Çanakkale Onsekiz Mart Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Temel Bilimler Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 80

Özet

Bu çalışma Ağustos 2013 ve Mart 2014 tarihleri arasında bir mezbaha atık su arıtma tesisinin deşarj noktası olan Çerpeş Deresi'nde 4 istasyonda mevsimsel olarak gerçekleştirilmiştir. Çalışmanın amacı atık su arıtma tesisinin deşarj noktasına olan fiziko-kimyasal ve biyolojik etkisini belirlemektir. Analiz sonuçlarına göre su sıcaklığı mevsim normallerinde seyretmiş olup 9°C - 27°C arasında değiştiği gözlemlenmiştir. İletkenlik değerleri 578 µs cm-1 - 3520 µs cm-1 arasında değişmiştir. Örneklemede nitrit (NO2) + nitrat (NO3), amonyum (NH4), orto fosfat (PO4-P) ve silikat (SiO2) gibi besin elementlerinin değerleri ise sırasıyla 0.0316 µM – 5.0494 µM, 0.0001 µM – 0.0151 µM, 0.004 µM – 0.310 µM, ve 2.26 µM – 5.03 µM arasında değişim göstermiştir. Askıda katı madde (AKM)'nin en yüksek değerleri deşarj noktasında tespit edilmiş olup, 1.2 µg L-1 - 104 µg L-1 arasında ölçülmüştür. Yağ ve gres miktarı için sadece kış mevsiminde örnekleme yapılmış, deşarjdan önce bulunan istasyon harici diğer bütün istasyonlarda Su Kirliliği Kontrol Yönetmeliği Standartları'nın (SKKY, 2004) üzerinde seyrettiği gözlemlenmiş ve değerleri 19.40 mg L-1 – 62.40 mg L-1 arasında değişmiştir. Biyolojik oksijen ihtiyacı (BOİ) ve kimyasal oksijen ihtiyacı (KOİ) değerleri sırasıyla 10.42 mg L-1 – 514.48 mg L-1 ve 19.51 mg L-1 – 1268.28 mg L-1 arasında seyretmiş ve genelde SKKY limitlerinin üzerinde olduğu gözlemlenmiştir. Klorofil-a konsantrasyonu 0.078 µg L-1 ve 13.79 µg L-1 arasında değişmiştir. Alıcı suyun mikrobiyal kalitesini belirlemek amacıyla fekal / toplam koliform bakteri değerleri de ölçülmüştür. Fekal / toplam koliform için sırasıyla 520 EMS/100 ml - 11000 EMS/100 ml, 1100 EMS/100 ml - 11000 EMS/100 ml arasında seyreden değerler, sistemde yüksek miktarda kirlenme olduğunu göstermiştir. Çevresel parametrelerin sonuçları, çalışma alanının su kalitesinin istasyonlar arasında mevsimsel olarak değiştiğini, 1. istasyonun“IV. kalitede”ve“çok kirlenmiş su”olarak belirtilirken 2., 3. ve 4. istasyonların“III. kalitede”ve“kirlenmiş su”olduğu belirlenmiştir.

Özet (Çeviri)

This study was conducted seasonally in four sampling stations in the discharge point of a slaughterhouse waste treatment system in Çerpeş Creek (Gönen-Balıkesir, Turkey) between August 2013 and March 2014. The aim of this study was to determine the physicochemical and biological effects of waste treatment's effluent to the discharge point. According to the analysis results temperature changed between 9ºC and 27ºC among sampling stations that were being in the seasonal ranges. Conductivity ranged between 578 µs cm-1 and 3520 µs cm-1. Nutrients such as nitrite+nitrate (NOx), ammonium (NH4), orthophosphate (PO4-P) and silicate (SiO2) varied among sampling stations having the values 0.0316 µM – 5.0494 µM, 0,0001 µM – 0.0151 µM, 0.004 µM – 0.310 µM, and 2.26 µM – 5.03 µM, respectively. Total suspended solids (TSS) were measured between 1.2 µg L-1 and 104 µg L-1 and found to have the highest values in the first station which was the discharge point. Greased oil was only analyzed during winter sampling, and found to be over the Water Pollution Control Regulation standards in all stations except the second station which was prior to the discharge point, with the values changing between 19.40 mg L-1 and 62.40 mg L-1. Biological (BOD) and Chemical (COD) oxygen demand values were generally higher than the pronounced values in the Water Pollution Control Regulation standards ranging between 10.42 mg L-1 – 514.48 mg L-1, and 19.51 mg L-1 – 1268.28 mg L-1, respectively. Chlorophyll-a concentration changed between 0.078 µg L-1 and 13.79 µg L-1 among sampling stations, seasonally. In order to determine the microbial quality of the receiving water fecal and total coliform bacteria counts were also performed. Results showed that fecal and total coliform counts varied between 520 cfu/100 ml - 11000 cfu/100 ml and 1100 cfu/100 ml - 11000 cfu/100 ml, showing a high contamination in the system. Results of the environmental parameters indicated that the water quality of the study area changed seasonally among stations, and while the first station can be referred as the“fourth order quality”which can be considered as“very polluted”, the second, third and fourth stations can be considered as“polluted”having“third order quality”.

Benzer Tezler

  1. Erzurum et kombinası atıksularının arıtılmasında model sistem geliştirilmesi

    Başlık çevirisi yok

    ÜMMÜHAN DANIŞ

    Yüksek Lisans

    Türkçe

    Türkçe

    1991

    Çevre MühendisliğiAtatürk Üniversitesi

    PROF.DR. ORHAN ÖZBAY

  2. Seyreltik mezbaha boyun kanının kesikli ardışık biyolojik reaktöre entegre edilmiş batık membran filtrasyon sistemi ile arıtımının araştırılması

    Investigation of treatment by sequence batch reactor integrated with submerged membran bioreactor of diluted slaughterhouse neck blood

    İREM BALIK

    Yüksek Lisans

    Türkçe

    Türkçe

    2019

    Çevre MühendisliğiAtatürk Üniversitesi

    Çevre Mühendisliği Ana Bilim Dalı

    DOÇ. DR. OKAN TARIK KOMESLİ

  3. Hibrit ultrases ve ileri oksidasyon prosesleri kullanılarak kanatlı endüstrisi atık sularının arıtılması

    Treatment of poultry industry wastewater by using of hybrid ultrasound and advanced oxidation processes

    NAZMİYE EBRU ŞEN

    Yüksek Lisans

    Türkçe

    Türkçe

    2023

    Çevre MühendisliğiBolu Abant İzzet Baysal Üniversitesi

    Çevre Mühendisliği Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ GAMZE DOĞDU

  4. Yüksek organik kirliliğe sahip mezbaha endüstrisi atıksularının arıtımı için membran entegre biyoreaktör geliştirilmesi

    Development of membrane integrated bioreactor for treatment of slaughterhouse industry wastewaters which contains highly organic pollutants

    SÜLEYMAN UZUNER

    Doktora

    Türkçe

    Türkçe

    2021

    Çevre MühendisliğiBalıkesir Üniversitesi

    Çevre Mühendisliği Ana Bilim Dalı

    PROF. DR. BURHANETTİN FARİZOĞLU

  5. Reed beds and industrial applications: Treatment of tannery effluent

    Saz yatakları ve endüstriyel uygulamaları: Tabakhane atıksularının arıtımı

    ÖZTAN SANİYE KÜÇÜK

    Yüksek Lisans

    İngilizce

    İngilizce

    2001

    Çevre MühendisliğiDokuz Eylül Üniversitesi

    Çevre Teknolojileri Ana Bilim Dalı

    PROF.DR. FÜSUN ŞENGÜL