Geri Dön

İç ve dış hava ortamlarında partiküler madde (PM10, PM2.5 ve PM1) konsantrasyonlarının değerlendirilmesi

Assessment of particulate matter (PM10, PM2.5 and PM1) concentrations in indoor and outdoor environments

  1. Tez No: 387361
  2. Yazar: BİLGE KARAKAŞ
  3. Danışmanlar: PROF. DR. GÜLEN GÜLLÜ
  4. Tez Türü: Yüksek Lisans
  5. Konular: Çevre Mühendisliği, Environmental Engineering
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2015
  8. Dil: Türkçe
  9. Üniversite: Hacettepe Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Çevre Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 153

Özet

Gerçekleştirilen bu çalışma, 0-2 yaş dönemi çocukların vakitlerinin önemli bir kısmını geçirdikleri kapalı ortamlardaki partikül madde (PM10, PM2.5 ve PM1) seviyelerinin ve kaynaklarının belirlenmesi ile sonuçların ev ve çevre koşullarına göre etkilerinin incelenmesi üzerinedir. Tez çalışması kapsamında Ankara ilinin çeşitli semtlerinde, evlerin oturma ve bebek odası ile dış ortamlarında PM ölçümleri gerçekleştirilmiştir. Çalışma sırasında araştırmaya katılan ailelerin evlerinde eşzamanlı olarak PM10, PM2.5 ve PM1 ölçümleri gerçekleştirilerek, aynı zamanda bu ortamlarda yaşayan bireylerin yaşam alışkanlıkları, ev ve çevre koşulları da kayıt altında tutulmuştur. Bazı ölçüm dönemlerinde sıcaklık, bağıl nem ve CO2 konsantrasyonları da anlık olarak ölçülmüştür. Çalışmada, 6 saniye aralıklar ile elektronik kayıt sağlayan, havadan taşınan partiküllerin konsantrasyonunu ölçmek için geliştirilmiş“Grimm Environmental Dust Monitor (EDM) 107”toz konsantrasyonu ölçüm cihazı kullanılmıştır. Ölçümler her bir mikro ortamda 15 dakika süre ile gerçekleştirilmiştir. Çalışmanın sonucunda genel olarak iç ortam PM seviyelerinin büyük oranda ortak kullanılan odalarda, ayrı olarak ise oturma ve bebek odalarına oranla yüksek olduğu gözlenmiştir. Ayrıca, bebek odalarında gerçekleştirilen ölçüm sonuçlarının oturma odasına göre düşük olduğu tespit edilmiştir. CO2 seviyelerinin ise EPA'nın belirlediği limit değer olan 800 ppm'in üzerinde olduğu belirlenmiştir. Dış ortam ölçümleri gerçekleştirilen dönemlerde oturma ve bebek odalarına ait İ/D konsantrasyon oranları tüm kirleticiler için birden büyük olduğu dolayısıyla kirletici kaynağının iç ortamdan kaynaklandığı gözlenmiştir. Ev koşullarına göre yapılan analizlerde; soba ile ısınan evlerde PM10 konsantrasyonunun kombi kullanımı olan evlere göre yüksek, evin içerisinde sigara kullanılan evlerde sadece balkonda sigara içilen ve sigara içilmeyen evlere göre yüksek, dış ortamda PM konsantrasyonlarının örnekleme esnasında çevrede inşaat faaliyetlerinin olduğu evlerin olmayanlara göre yüksek olduğu gözlenmiştir. Dış hava kalitesinin ise meteorolojik faktörler ile belirgin değişim gösterdiği saptanmıştır.

Özet (Çeviri)

This study is about determining the levels and sources of particulate matter (PM10, PM2.5 and PM1) in indoor environments where 0 to 2 years old children spend most of their time and examining the impacts of the results according to domestic and environmental conditions. Within the scope of thesis, PM measurements were carried out in the living, babies rooms and outdoor environments of the houses present in various districts of Ankara. During this study, PM10, PM2.5 and PM1 measurements were carried out simultaneously in the houses of the participant families and at the same time, the life styles of the family members and domestic and environmental conditions were recorded. In some of the measurement periods, temperature, relative humidity and CO2 concentrations were also measured instantly. In the study,“Grimm Environmental Dust Monitor (EDM) 107”dust concentration measurement device developed to measure the airborne particle concentration and record the data every 6 seconds was used. The measurements were carried out for 15 minutes en each micro environment. As a result of the study, it was observed that: generally indoor PM levels were significantly higher in the joint rooms which were used for both living and baby room purposes compared to living and babies rooms. It was also determined that the measurement results were lower in the babies rooms compared to living rooms. It was identified that the CO2 levels were higher than the limit value of 800 ppm determined by EPA. Indoor to outdoor ratios for both living and baby rooms were higher than one meaning that the source of pollution was indoor environment. According to analyses of house conditions; PM10 concentration was higher in houses heated by stove compared to houses heated by central heating boiler; it was also higher in houses where cigarette is smoked within the house compared to houses where the cigarette is smoked only in the balcony or not smoked; the outdoor PM concentrations were higher in the houses around which a building was under construction compared to houses with no construction around. On the other hand, it is found out that the outdoor air quality varies significantly depending on the meteorological conditions.

Benzer Tezler

  1. İç ortam hava kalitesini etkileyen kirletici ve konfor parametrelerinin kaynakları ve enerji tüketimi açısından incelenmesi

    Investigation of indoor air quality based on sources of pollutant and comfort parameters and energy consumption

    AYŞE TÜLAY SELİCİ

    Doktora

    Türkçe

    Türkçe

    2014

    Çevre MühendisliğiBalıkesir Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    DOÇ. DR. NADİR İLTEN

    DOÇ. DR. LOKMAN HAKAN TECER

  2. Hastane ve diş kliniklerinin iç ve dış ortam havasında partikül fazındapolisiklik aromatik hidrokarbon ve ftalat esterlerinin seviyelerinin değerlendirilmesi

    Evaluation of the levels of polycycic aromatic hydrocarbon and phthalate esters in particle phase in indoor and outdoor air of hospitals and dental clinics

    HEPSEN BAHAR GEMİCİ

    Yüksek Lisans

    Türkçe

    Türkçe

    2023

    Çevre MühendisliğiKocaeli Üniversitesi

    Çevre Mühendisliği Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ DEMET ARSLANBAŞ

  3. Assessment of urbanization history of Addis Ababa city, Ethiopia

    Addıs Ababa cıty, Ethıopıa'nın kentleşme tarihinin değerlendirilmesi

    ABDURAHMAN HUSSEN YIMER

    Yüksek Lisans

    İngilizce

    İngilizce

    2023

    Şehircilik ve Bölge PlanlamaMersin Üniversitesi

    Şehir ve Bölge Planlama Ana Bilim Dalı

    DOÇ. DR. ALİ CENAP YOLOĞLU

  4. Bir boya fabrikasında iç hava kalitesi ve işçi sağlığı üzerinde etkilerinin değerlendirilmesi

    Investigation of indoor air quality and effects on workers' healty in a paint factory

    NURAY GÖKÇEN

    Yüksek Lisans

    Türkçe

    Türkçe

    2015

    Çevre MühendisliğiNamık Kemal Üniversitesi

    Çevre Mühendisliği Ana Bilim Dalı

    PROF. DR. LOKMAN HAKAN TECER

  5. İstanbul'da farklı iç ortamlarda hava kalitesinin belirlenmesi

    Determination of air quality in different indoor environments in Istanbul

    TANSU HAKSEVENLER

    Yüksek Lisans

    Türkçe

    Türkçe

    2010

    Çevre Mühendisliğiİstanbul Üniversitesi

    Çevre Mühendisliği Ana Bilim Dalı

    YRD. DOÇ. DR. BURCU ONAT