TLD-600 (LiF-6:Mg,Ti) ve TLD-700 (LiF-7:Mg,Ti) dozimetrelerinin nötron dozuna duyarlılığının incelenmesi ve radyoterapide kullanılan lineer hızlandırıcı cihazlarında dozimetri amacı ile kullanılabilirliğinin araştırılması

Investigation of TLD-600 (LiF-6:Mg,Ti) and TLD-700 (LiF-7:Mg,Ti) dosemeters sensitivity to neutron dose and investigation of usability of TLD-600 and TLD-700 for the purpose of dosi̇metry in linear accelerator devices used in radiotherapy.

  1. Tez No: 406425
  2. Yazar: SANAZ HENDİ
  3. Danışmanlar: DOÇ. DR. NİYAZİ MERİÇ
  4. Tez Türü: Yüksek Lisans
  5. Konular: Fizik ve Fizik Mühendisliği, Radyoloji ve Nükleer Tıp, Physics and Physics Engineering, Radiology and Nuclear Medicine
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2015
  8. Dil: Türkçe
  9. Üniversite: Ankara Üniversitesi
  10. Enstitü: Nükleer Bilimler Enstitüsü
  11. Ana Bilim Dalı: Medikal Fizik Ana Bilim Dalı
  12. Bilim Dalı: Sağlık Fiziği Bilim Dalı
  13. Sayfa Sayısı: 73

Özet

Nükleer bilimi zamanla gelişme kaydettikçe medikal, sanayi ve teknoloji gibi çeşitli alanlarda da kullanılmaya başlanmıştır. Bununla birlikte radyasyon dozunun ölçülmesi ve kişisel dozimetrelerin önemi artmıştır. Gamalarla karşılaştırıldığında nötronların biyolojik etkinlikleri daha yüksek olduğundan nötron dozimetresi radyasyondan korunmada büyük önem taşır. LiF:Mg,Ti dozimetreler gama dozuna olan yüksek hassasiyetleri, dokuya eşdeğer olmaları, ısıya karşı olan dayanıklılıkları ve göz ardı edilebilir sönümlenme zamanları nedeniyle uzun zamandan beri radyasyon dozimetresi olarak kullanılırlar. Nötron dozunun ölçülmesinde yaygın olarak kullanılan yöntemlerden biri TLD-600 ve TLD-700 dozimetrelerinin bir arada kullanılmasıdır. Nötron dozuna duyarlı olan TLD-600 ve nötron dozuna karşı duyarlı olmayan TLD-700 olmak üzere iki çeşit dozimetri kullanılmaktadır. Bu çalışmanın hedefi nötron-gama karışımı olan radyasyon alanlarında termal nötronlarının dedeksiyonu için TLD-600(LiF-6:Mg,Ti) ve TLD-700(LiF-7:Mg,Ti) dozimetrelerinin nötron dozuna duyarlılığının incelenmesi ve radyoterapide kullanılan lineer hızlandırıcı cihazlarında dozimetri amacı ile kullanılabilirliğinin araştırılmasıdır. Bu çalışmada TLD-600 ve TLD-700'ler 100 mGy gama dozuna maruz bırakıldı ve tekrarlanabilirlikleri birbirine en yakın TLD'ler seçildi. Seçilen TLD'ler 10 mGy nötron dozunda ışınlandı ve ışıma eğrileri ayrıştırıcı programı kullanılarak piklerine ayrıştırıldı ve dördüncü pikleri birbirine en yakın şiddeti veren altı TLD (üç TLD-600 ve üç TLD-700) seçildi. TLD'ler lineer hızlandırıcı cihazında on farklı dozda ışınlandı (0,5Gy, 0,75Gy, 1Gy, 1,5Gy, 2Gy, 2,5Gy, 3Gy, 5Gy, 7,5Gy, 10 Gy). Elde edilen ışıma eğrileri piklerine ayrıştırıldı ve her bir pike ait doz-cevap eğrisi çizildi. Nötron dozuna duyarlı olan dördüncü pik için doz-cevap eğrisi ve X-ışını dozu-nötron dozu grafikleri çizildi. Elde edilen verilere göre nötronun tedavi dozuna olan katkısı yaklaşık olarak %0,113'tür. 10 rad (0.1Gy) ve altı radyasyon dozlarında biyolojik etkinin göz ardı edilecek kadar az olduğu (HPS 1996) göz önünde bulundurulursa bu değerler uygulanan tedavi dozunu etkilemeyecektir ve ikincil kanser riski oluşmayacaktır.

Özet (Çeviri)

During the last years due to the development and estabilishment of the nuclear science, dosimetry has become a mandatury task. In addition to this, the measurements of radiation dose using personel dosimeters have become significant. especially when it comes Gamma rays due to higher biological effects of neutron dose, have an important role in order to protect from radiation. LiF:Mg dosimeters have been used for long time ago because of high sensitivity, being tissue equivalent, resistance to heat and negligible decay time. One common fort he measuring the nuetron dose is to use TLD-600 and TLD-700 together. These kinds of Dosimeters were used , namely TLD-600 which is sensitive to neutron dose, and TLD-700, the letter is not. The aim of this study is to investigate the sensitivity of the TLD-600 and TLD-700 dosimeters for detection of the thermal neutrons in the fields of radiation which include mixed neutron particles and gamma rays, as well as to research being used as a dosimeter for linear accelarators in radiation therapy. In this study, TLD-600 and TLD-700 were exposed to 100 mGy gamma dose and the TLD's which yielded good reproducibility were chosen. Selected TLD's were exposed to 10mGy neutron dose and the glow curves were de-convoluted into individual peaks, using the general order kinetics model. TLDs having the fourth peak with identical intensity were selected (three TLD-600 and three TLD-700). TLD's were irradiated at ten different doses in linear accelerator device (0,5Gy, 0,75Gy, 1Gy, 1,5Gy, 2Gy, 2,5Gy, 3Gy, 5Gy, 7,5Gy, 10 Gy). The obtained glow curves were separated into peaks and the dose-response curve was derived for each peak. Dose-response curve and X-ray-neutron graphic plotted for fourth peak which is sensitive to the neutron dose. According to the results obtained the contribution of neutrons to the total therapy dose is approximately 0.113%. considerably, below 10 rad (0.1Gy) the risks of health effects are either too low to be observed or even non-existent (HPS 1996), these values will not affect the treatment dose and there will be no risk of secondary cancer.

Benzer Tezler

  1. Investigation of thermoluminescence response of TLD-600 and TLD-700 dosimeters to neutron+gamma and beta radiations

    TLD-600 ve TLD-700 dozimetrelerinin nötron+gama ve beta radyasyonlarına karşı termoluminesans davranışlarının araştırılması

    BÜŞRA YAZICI

    Yüksek Lisans

    İngilizce

    İngilizce

    2018

    Fizik ve Fizik MühendisliğiGaziantep Üniversitesi

    Fizik Mühendisliği Ana Bilim Dalı

    DOÇ. DR. VURAL EMİR KAFADAR

  2. Development of new thermoluminescent dosimeters for neutron measurements

    Nötron ölçümleri için yeni termolüminesans dozimetrelerin geliştirilmesi

    SERA İFLAZOĞLU

    Doktora

    İngilizce

    İngilizce

    2017

    Fizik ve Fizik MühendisliğiGaziantep Üniversitesi

    Fizik Mühendisliği Ana Bilim Dalı

    PROF. DR. AHMET NECMEDDİN YAZICI

    DOÇ. DR. VURAL EMİR KAFADAR

  3. Konformal ve yoğunluk ayarlı radyoterapi teknikleri ile yapılan meme ışınlamalarında fetüs dozunun araştırılması

    Made with conformal and intensity modulated radiotherapy techniques in breast irradiation investigation of the dose to the fetus

    AKIN ÖĞRETİCİ

    Yüksek Lisans

    Türkçe

    Türkçe

    2015

    Fizik ve Fizik Mühendisliğiİstanbul Üniversitesi

    Temel Onkoloji Ana Bilim Dalı

    PROF. DR. HATİCE BİLGE

  4. Farklı iyon katkılı lityum tetraborat fosforların optiksel özelliklerinin ve termolüminesans mekanizmalarının incelenmesi

    Investigation of optical properties and thermoluminescence mechanisms of different ion doped lithium tetraborate phosphors

    DİLEK ERDEMLİ

    Doktora

    Türkçe

    Türkçe

    2019

    Fizik ve Fizik MühendisliğiEge Üniversitesi

    Nükleer Bilimler Ana Bilim Dalı

    PROF. DR. TURGAY KARALI

  5. Binek otomobillerde kullanılan el fren kumanda tellerinde verimliliğe etki eden parametrelerin incelenmesi

    Investigation of the parameters affecting efficiency in hand brake control wires in a car

    SAMET REÇEL

    Yüksek Lisans

    Türkçe

    Türkçe

    2019

    Mühendislik BilimleriPamukkale Üniversitesi

    Makine Eğitimi Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ HİLAL CAN