R134a ve R744 ile çalışan otobüs klimalarında iki fazlı ejektörün genleşme valfi olarak kullanılması durumunda sistemin çeşitli parametrelere göre analizi

The analysis of bus refrigeration system working with R134a and R744 refrigerants according to different parameters in case of using two-phase ejector as expansion valve

  1. Tez No: 423988
  2. Yazar: ÇAĞRI KUTLU
  3. Danışmanlar: YRD. DOÇ. DR. ŞABAN ÜNAL
  4. Tez Türü: Yüksek Lisans
  5. Konular: Makine Mühendisliği, Mechanical Engineering
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2015
  8. Dil: Türkçe
  9. Üniversite: Osmaniye Korkut Ata Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Makine Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Günümüzde otobüslerin hemen hemen hepsinde klima sistemleri mevcuttur. Otobüs klima sistemlerinde kullanılan kompresör, otobüs motoruna bağlı bir kasnak ile tahrik edilmektedir. Ancak bu durum motora fazladan bir yük getirmektedir ve yakıt tüketimini arttırmaktadır. Otobüslerdeki klimaların soğutma etkinliklerinin arttırılması ile sistemde yakıt tüketiminin azaltılması sağlanabilecektir. Klima etkinliğinin arttırılmasına yönelik çalışmalardan birisi genleşme valfi yerine iki fazlı ejektörün kullanılmasıdır. Böylece genleşme valfinde kaybolan işin geri dönüşümü sağlanacak ve bu iş ile kompresörün harcayacağı iş azalacak ve böylelikle sistemin soğutma etkinliği (COP) artacaktır. Bu çalışmada, günümüzde taşıt iklimlendirme sistemlerinde yaygın olarak kullanılan soğutucu akışkan R134a ile çalışan ve klasik çevrimden farklı olarak genleşme valfi yerine iki fazlı ejektör kullanılan sistemin çeşitli parametrelere göre analizi yapılacaktır. Ayrıca, son zamanlarda küresel ısınma ile ilgili kaygıların artması ile birlikte, yapay soğutucu akışkanların küresel ısınmaya neden oldukları bilindiğinden, taşıt iklimlendirme sistemlerinin yapay soğutucu akışkanlar yerine R744 (CO2) gibi doğal soğutucu akışkanların kullanılmasına dönüşün başlamasından dolayı, R744 ile çalışan ve klasik çevrimden farklı olarak genleşme valfi yerine iki fazlı ejektör kullanılan sisteminde çeşitli parametrelere göre analizi yapılacaktır.

Özet (Çeviri)

Nearly in all of today's buses and midibuses, air-conditioning systems are available. Compressor of the air-conditioning system is driven by pulley connected to the engine shaft. Due to the extra load on the engine, fuel consumption is increased. As a result of increasing COP, it's possible to use smaller size of air conditioner elements and decrease of fuel consumption. COP of the air conditioning system can be increased by using two phase ejector. So expansion loses in expension valve can be recovered and this yields decrease of compressor work, thus COP would be increased. In scope of this study, firstly, two-phase ejector refrigeration cycle operating with R134a is analyzed for the bus air conditioning with different parameters. In addition to this, increasing concers about global warming and it's known that artificial refrigerants causes to this, natural refrigerants like R744 (CO2), started to replace artificial refrigerants. So two-phase ejector refrigeration cycle operating with R744 is also analyzed for the bus air conditioning system.

Benzer Tezler

  1. Exergy and exergeconomic analysis of solar assisted heat pump system

    Güneş enerjisi destekli ısı pompası sisteminin ekserji ve eksergoekonomik analizi

    DEEDAR RAOOF MOHAMMED

    Yüksek Lisans

    İngilizce

    İngilizce

    2018

    Gaziantep Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  2. Mevcut soğutma gruplarının yeni soğutucu akışkanlara adaptasyonu

    The Present cooler groups will have to adapted with vew cooler fluids

    KEMAL ORTATEPE

    Yüksek Lisans

    Türkçe

    Türkçe

    1997

    Marmara Üniversitesi

    Makine Eğitimi Ana Bilim Dalı

    Yükleniyor...

  3. R-134a akışkanın termodinamik özelliklerinin hesaplanması ve kullanılabilirlik diyagramları

    Başlık çevirisi yok

    KIVANÇ ÖZEKMEKÇİ

    Yüksek Lisans

    Türkçe

    Türkçe

    1998

    İstanbul Teknik Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  4. Büro mobilyaları imalat sisteminin incelenmesi ve iş yeri düzenleme çalışmaları

    Başlık çevirisi yok

    NİL ÖZKÖK

    Yüksek Lisans

    Türkçe

    Türkçe

    1998

    İstanbul Teknik Üniversitesi

    İnşaat Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  5. Yolcu taşıtlarının iklimlendirilmesi

    Air conditioning of passenger vehicles

    MERT BATIRAN

    Yüksek Lisans

    Türkçe

    Türkçe

    1998

    İstanbul Teknik Üniversitesi

    Makine Ana Bilim Dalı

    Yükleniyor...