Geri Dön

İdrarda UR-144 ve metabolitlerinin LC-MS/MS ile tayinleri

Determination of UR-144 and metabolites in urine with LC-MS/MS

  1. Tez No: 426049
  2. Yazar: ERGÜN KARAOĞLU
  3. Danışmanlar: PROF. DR. BELGİN İZGİ
  4. Tez Türü: Yüksek Lisans
  5. Konular: Adli Tıp, Forensic Medicine
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2016
  8. Dil: Türkçe
  9. Üniversite: Uludağ Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Kriminalistik Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Esrarın yan etkilerini azaltarak tedavi edici etkisini geliştirmek üzere sentezlenen sentetik kannabinoidler son yıllarda esrara alternatif olarak kullanılmakta ve suistimali tehlikeli boyutlara ulaşmıştır. Endokannabinoid reseptörlere tetrahidrokannabinol (THC)'e benzer etki gösteren fakat farklı kimyasal yapıdaki bu maddeler, ciddi yan etkilere hatta ölümlere neden olabilmektedirler. Sentetik kannabinoidlerin bitkisel materyaller üzerine spreylenmesiyle hazırlanan karışımlar“doğal”ve“yasal”kandırmacasıyla internet üzerinden kolaylıkla satılmakta ve popülariteleri gün geçtikçe artmaktadır. Maddelerin farmakolojisi, toksik etkileri ve tayiniyle ilgili yapılan çalışmalar oldukça sınırlıdır.“Tütsü”gibi isimlerle adlandırılan Spice, Yucatan Fire, Smoke, Sence, Skunk ve Space gibi ticari isimlerle piyasaya sürülen bu maddeler esrardan daha güçlü bir etki oluşturmaktadır. Buna ek olarak yasal kapsama alınmadığı için rahatlıkla ticareti yapılabilmektedir. Artan popülaritesi ve olası hasar potansiyeli nedeniyle“spice”Türkiye'de 2011 yılında yasa kapsamına alınması nedeniyle bileşenlerinin analizine adli toksikolojide ihtiyaç duyulmuş ve tayini gerekli hale gelmiştir. UR-144, UR-144 N-pentanoik asit ve UR-144 N-(5-hidroksipentil) maddelerinin katı faz ekstraksiyonu yapılarak LC-MS/MS analizi ile idrarda tayini ve miktar belirlenmesi amacıyla spesifik ve güvenilir bir metot geliştirilmiştir. Metodun validasyonu doğrusallık (0,1 – 100 ng/mL), seçicilik, gün içi ve günler arası doğruluk ve kesinlik (CV < %15), geri kazanım (% 81-99), gözlenebilme sınırı (LOD) (0,05-0,09 ng/mL), ve gözlenebilme miktarı (LOQ) (0,17-0,31 ng/mL) parametreleri dikkate alınarak yapılmıştır. Ayrıca matriks etkisi, kararlılık ve işlem etkileri de incelenmiştir.

Özet (Çeviri)

Synthetic cannabinoids are synthesized to improve the therapeutic effect of marijuana by reducing the adverse effects of it but cannabis are now being used as alternative of marijuana and its widespreadening has reached dangerous proportions abusively. The endocannabinoid receptors for tetrahydrocannabinol (THC) showing similar effects to these substances but with different chemical structures, they cause serious side effects even death. It is increasingly getting popular and available on internet to reach Synthetic cannabinoids which prepared as liquid spray and applied over mixtured various plant materials under mask of“natural”and“legal”trade labels in the market day by day. Unfortunatelly, pharmacologic, toxic effects and determination of cannobinoid substances related studies are very limited. Trading traffic of those substances in the market held by different names such“Incense, Spice, Yucatan Fire, Smoke, Sence, Skunk”and these substances have more effective than marijuana. Additionaly legal gaps and abstractness of legal regulations provides easiness on trading of that substances in the market. It became required to analyze and identificate for forensic toxicology when a legal legislation made in 2011 which aims to prevent the dangerously increasing popularity and damage potential of“spice”in Turkey. A specific and reliable method has been developed for the detection and quantification of UR-144, UR-144 N-pentanoic acid and UR-144 N- (5-hydroxypentyl) in urine using solid-phase extraction by LC–MS/MS analysis. The method has been validated in terms of linearity (0,1 – 100 ng/mL), selectivity, intra-assay and inter-assay accuracy and precision (CV < 15%), recovery (81-99%), limits of detection (LOD) (0,05-0,09 ng/mL), and quantification (LOQ) (0,17- 0,31 ng/mL). Matrix effects, stability, and process efficiency were also assessed.

Benzer Tezler

  1. Prematüre osteopenisinde kantitatif usg ile belirlenen kemik mineral yoğunluğu ile kemik döngüsü belirleyicilerinin ilişkisi

    Comparison of bone mineral dansity determined by quantitative ultrasound with bone turnover parameters in preterm osteopenia.

    SALİM KÜÇÜK

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2008

    Çocuk Sağlığı ve HastalıklarıErciyes Üniversitesi

    Çocuk Sağlığı ve Hastalıkları Ana Bilim Dalı

    PROF. DR. MUSTAFA KENDİRCİ

  2. İnflamatuvar bağırsak hastalığı olanlarda tiroid fonksiyon testleri, ultrasonografi özellikleri ve idrar iyot düzeyleri

    Thyroid ultrasonography, thyroid hormones and urine iodine excretion levels in patients with inflammatory bowel disease

    AYBÜKE UYAR

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2020

    İç HastalıklarıAnkara Yıldırım Beyazıt Üniversitesi

    İç Hastalıkları Ana Bilim Dalı

    PROF. DR. DİDEM ÖZDEMİR

  3. Evre 3-4-5 kronik böbrek yetmezliği hastalarında ağız ve diş sağlığının malnütrisyon ile ilişkisi

    The relationship between oral and dental health and malnutrition in patients with stage 3-4-5 chronic renal failure

    SERDAR YAVUZ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2025

    NefrolojiSağlık Bilimleri Üniversitesi

    İç Hastalıkları Ana Bilim Dalı

    DOÇ. DR. EDİP ERKUŞ

  4. Hiperkalsiuri ile idrar N-asetil beta-D glukozaminidaz arasındaki ilişkinin araştırılması

    Investigation of relationship between hypercalciurna and urinary N-astyl beta-D glucosaminidase

    SALİH KAVUKÇU

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1997

    Çocuk Sağlığı ve HastalıklarıDokuz Eylül Üniversitesi

    Çocuk Sağlığı ve Hastalıkları Ana Bilim Dalı

    PROF.DR. ÜMİT SAATÇI

  5. Mobil telefon kullanımına bağlı oluşan 900-1800 mhz radyo frekans dalgalarının meydana getirdiği elektromanyetik alanın iliak kanat kemik mineral yoğunluğuna etkisi

    The effect of electromagnetic fields on bone mineral density of iliac bone produced by 900-1800 mhz radio frequency waves dependent on cellular phone usage

    BEŞİR ANDAÇ AKSOY

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2006

    Ortopedi ve TravmatolojiSüleyman Demirel Üniversitesi

    Ortopedi ve Travmatoloji Ana Bilim Dalı

    PROF.DR. NEVRES HÜRRİYET AYDOĞAN