Erişkin hastalarda timpanik membran termometresi ile yapılan ölçümlerde kulak kepçe pozisyonunun vücut sıcaklığı ölçüm değerlerine etkisi

In adult patients the effect that auricle's position has on the body's temperature measurement values during measurements performed through tympanic membrane thermometer

  1. Tez No: 433190
  2. Yazar: NİLAY ORKUN
  3. Danışmanlar: PROF. DR. İSMET EŞER
  4. Tez Türü: Yüksek Lisans
  5. Konular: Hemşirelik, Nursing
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2016
  8. Dil: Türkçe
  9. Üniversite: Ege Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Hemşirelik Esasları Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 65

Özet

Araştırma, erişkin hastalarda timpanik membran termometresi ile yapılan ölçümlerde kulak kepçe pozisyonunun vücut sıcaklığı ölçüm değerlerine ve rahatlık düzeyini etkisini incelemek amacı ile karşılaştırmalı tanımlayıcı olarak yapılmıştır. Araştırma, Kasım - Aralık 2015 tarihleri arasında Ege Üniversitesi Tıp Fakültesi Hastanesi Acil Servis'ine bu tarihlerde ayaktan başvuran ya da yatarak tedavi gören erişkin hastalarda yapılmıştır. Araştırmanın örneklemini, 18 yaş ve üstü, bilinci açık, iletişim sorunu olmayan, gönüllü, otitis mediası olmayan, ateşi olmayan, ayaktan başvuran ya da yatarak tedavi gören erişkin hastalar (n=147) oluşturmuştur. Ege Üniversitesi Tıp Fakültesi Hastanesi Acil Servis'ine başvuran günlük hasta sayısının fazla olması nedeni ile bu birim seçilmiştir. Araştırmada veriler, Veri Toplama Formu, Görsel Kıyaslama Ölçeği, timpanik membran termometresi ve kronometre kullanılarak toplanmıştır. Verilerin toplanmasında, araştırmaya dahil olma ölçütlerine uygun hastalar belirlendikten sonra araştırma hakkında bilgi verilmiştir, gönüllü olan hastalardan bilgilendirilmiş onam alınmıştır. Hastalarla ilgili tanıtıcı bilgiler, Veri Toplama Formuna kaydedildikten sonra hastanın hangi gruba alınacağı basit randomizasyonla belirlenmiştir, bunun için kura çekilmiştir. A grubundaki hastaların vücut sıcaklığı önce kulak kepçesi pozisyonu değiştirilerek ölçülmüştür. Ölçüm sırasında termometrenin kulak kanalında sıcaklık değişikliğine (sürtünme, plastik koruyucunun ısısının daha düşük olması gibi nedenler) neden olabileceği düşünülerek iki ölçüm arasında 30 saniye ara verilmiştir. Daha sonra ölçme işlemi hastanın kulak kepçesi pozisyonu değiştirilmeden yapılmıştır. B grubundaki hastaların vücut sıcaklığı ölçümü ise, önce kulak kepçesi pozisyonu değiştirilmeden, daha sonra ölçme işlemi hastanın kulak kepçesi pozisyonu değiştirilerek ölçüm yapılmıştır. Her bir vücut sıcaklığı ölçme işleminin süresi kronometre ile belirlenmiştir, işlemin rahatlık düzeyi Görsel Kıyaslama Ölçeği kullanılarak değerlendirilmiştir. Verilerin analizinde Statistical Package of Social Science (SPSS) 16.0 programı kullanılmıştır. Verilerin istatistiksel analizlerinde frekans, yüzde, ortalama, standart sapma hesaplanmış, kulak kepçe pozisyonunun ölçüm değerlerine etkisini incelemek için iki eş arasındaki farkın önemlilik testi kullanılmıştır. Ayrıca Bland Altman yöntemi ile verilere ilişkin grafikler oluşturulmuştur. Sonuçlar %95 güven aralığında, anlamlılık p

Özet (Çeviri)

Research was carried out in adult patients comparatively, descriptively to scrutinize the effect that auricle position has on the body's temperature measurement values and on the level of comfort during measurements performed through tympanic membrane thermometer. Research was carried out with adult out-patients or in-patients who referred to Emergency Department of Ege University Medical Faculty between November and December 2015. The sampling of research consisted of volunteer adult patients (18 years old or above) who were receiving therapy as in-patient or out-patient basis and were conscious, lacking communication problem, otitis media or fever (n=147). This unit was selected due to extreme number of daily referrals made to Emergency Department of Ege University Medical Faculty. In research data were collected by using Data Collection Form, Visual Comparison Scale, Tympanic Membrane Thermometer and Chronometer. During data collection, after patients that met inclusion criteria were identified, they were given information related to research and those that were volunteered to participate have provided informed consent. After the introductory data related to patients have recorded on Data Collection Form, to which groups they will be included in were determined through simple randomization (drawing lots). In group A, patients' body temperature was first measured by changing the position of auricle. During measurement (due to reasons such as friction, reduced temperature in plastic protector) 30-second breaks were given between two measurements since thermometer was thought to cause temperature change in ear canal. Later measurement process was performed without changing patient's auricle position. In group B, patients' body temperature measurement was first performed without changing the auricle position and later measurement was performed by changing the auricle position. The length of each body temperature measurement process was determined through chronometer; process's level of comfort was evaluated by using Visual Comparison Scale. Statistical Package of Social Science (SPSS) program version 16.0 was used in the analysis of data. In statistical analyses of data, the frequency, percentage, average and standard deviation were calculated and to investigate their effects on the auricle position measurement values, the significance between two pairs test was used. In addition, graphics related to data were drawn through Bland Altman method. Results were assessed at 95 % confidence interval and at p

Benzer Tezler

  1. Nötropenik hastaların vücut sıcaklığı ölçümünde aksiller, temporal ve timpanik bölgelerden yapılan ölçümlerin karşılaştırılması

    Comparison of measurement of body temperature fromaxillary temporal artery and tympanic membrane in neutropenic patients

    DERYA KADİFELİ

    Yüksek Lisans

    Türkçe

    Türkçe

    2018

    HemşirelikEge Üniversitesi

    Hemşirelik Esasları ve Yönetim Ana Bilim Dalı

    DOÇ. DR. DİLEK SARI

  2. Acil servise başvuruları kulak burun boğaz acili olarak değerlendirilen hastaların epidemiyolojik açıdan incelenmesi

    Epidemiology of otorhinolaryngology emergencies admitted to emergency deparment of Uludağ University Medical Faculty

    ENGİN ERTEK

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2016

    İlk ve Acil YardımUludağ Üniversitesi

    Acil Tıp Ana Bilim Dalı

    PROF. EROL ARMAĞAN

  3. Hastaneye yatırılan erişkin hastalarda vücut sıcaklığının aksiller ve timpanik ölçüm yöntemleri ile karşılaştırılması

    Comparison of body temperature with axillary and tympanic measurement methods in adult patients admitted to the hospital

    SUMMANİ DEMİRCİ

    Yüksek Lisans

    Türkçe

    Türkçe

    2018

    Mühendislik BilimleriAfyon Kocatepe Üniversitesi

    Biyomedikal Mühendisliği Ana Bilim Dalı

    DOÇ. DR. LEVENT ÖZCAN

    PROF. DR. ELİF DOYUK KARTAL

  4. Bell paralizili hastalarda kulak MR'da kontrast tutulum değerlerinin incelenmesi

    Evaluation of contrast enchancment values in the temporal MRI for patients with bell's palsy

    EGEMEN CENGİZ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2022

    Kulak Burun ve BoğazOndokuz Mayıs Üniversitesi

    Kulak Burun Boğaz ve Baş-Boyun Cerrahisi Ana Bilim Dalı

    PROF. DR. SİNAN ATMACA

  5. Spinal anestezi altında gerçekleştirilen artroskopik cerrahide deksmedetomidin ve tramadolün titreme üzerine etkileri

    The effects of intravenous tramadol and dexmedetomidine on shivering during arthroscopic surgery under spinal anesthesia

    ŞEMSETTİN BOZGEYİK

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2010

    Anestezi ve ReanimasyonGaziantep Üniversitesi

    Anesteziyoloji ve Reanimasyon Ana Bilim Dalı

    YRD. DOÇ. DR. AYŞE MIZRAK