Kablosuz yakın kızılaltı spektroskopisinin güvenirliği ve geçerliği

Reliability and validity of wireless near-infrared spectroscopy

  1. Tez No: 480981
  2. Yazar: SAVAŞ AKBAŞ
  3. Danışmanlar: YRD. DOÇ. DR. SERDAR ORKUN PELVAN
  4. Tez Türü: Yüksek Lisans
  5. Konular: Spor, Sports
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2017
  8. Dil: Türkçe
  9. Üniversite: Marmara Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Beden Eğitimi ve Spor Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 77

Özet

Amaç: BSX yakın kızılatı spektroskopi (BSX-YKAS) aygıtının, kas içi hemoglobinin oksijen doygunluğunu (Hb-SmO2) belirlemede güvenirliğini ve geçerliğini ölçmektir. Gereç ve yöntem: 14 gönüllü erkek sporcu (22.9±2.6 yıl) dinlenik ve izometrik kasılma olarak belirlenen güvenirlik ölçümlerine katıldılar. Dinlenik ölçümlerde, biceps brachii (BB) ile vastus lateralis (VL) kaslarından eş zamanlı kayıt alınmış ve bu kayıt değişmeli olarak farklı BSX-YKAS aygıtlarıyla altı kez tekrarlanmıştır. Tüm ekstremite verileri Pearson korelasyonu ile ilişkilendirilmiş, korelasyon değerleri tekrarlı ölçüm ANOVA ile karşılaştırılmıştır. İzometrik ölçümlerde BB ve VL kasından maksimum istemli kasılmanın %20, %40 ve %60 düzeylerinde Hb-SmO2 bir dakika boyunca ölçülmüş ve düşüş eğimi hesaplanmıştır. Üç kuvvet düzeyi arasındaki fark ANOVA ile sınanmıştır. Farklı bir BSX-YKAS aygıtıyla ölçüm tekrarlanmış ve ölçümlerin sınıf içi güvenilirlik katsayıları hesaplanmıştır. Geçerlik ölçümlerinde önkol iskemisi ve kademeli koşu testi gerçekleştirilmiştir. Önkol iskemisinde iki kolda altı dakika boyunca Hb-SmO2 düşüşü kaydedilmiş ve aralarında Pearson korelasyon katsayısı hesaplanmıştır. Kademeli koşu testinde gastroknemius kaslarına giydirilen BSX-YKAS aygıtlarıyla Hb-SmO2, ZAN ergospirometreyle oksijen tüketimi ve karbondioksit üretimi ölçülmüştür. Solunum eşiği (SE) ile YKAS zaman dizilerindeki kırılma noktası (KN) karşılaştırılmıştır. Bulgular: Tekrarlı dinlenme ölçümleri arasında fark bulunmamıştır (p>0.05). İzometrik ölçümlerde, farklı kuvvet düzeylerindeki Hb-SmO2 düşüş eğimleri arasında anlamlı bir fark bulunmuştur (p0.05). İzometrik ölçümlerde, farklı kuvvet düzeylerindeki Hb-SmO2 düşüş eğimleri arasında anlamlı bir fark bulunmuştur (p

Özet (Çeviri)

Objectives: To assess validity and reliability of the wearable BSX near infrared spectroscopy (BSX-Nirs) device for the measurement of oxygen saturation levels of hemoglobin (Hb-SmO2). Methods: Fourteen male athletes (22.9±2.6 years) voluntarily enrolled to reliability measurements at rest and during isometric contraction. Simultaneous recording were taken from biceps brachii (BB) and vastus lateralis (VL) of both extremities at rest, and repeated six times. The data from right and left extremities were correlated by using Pearson correlation and statistical significance was evaluated by using repeated ANOVA. During isometric measurements at 20%, %40, and %60 of maximal voluntary contraction, Hb-SmO2 was measured for one minute in the respective muscles, and the slope of decline was calculated. Statistical differences at the three different test conditions were assessed by using ANOVA. The whole measurement was repeated with a different BSX measurement device, and intra-class correlation coefficients were calculated. For validation, forearm ischemia and a graded treadmill tests have been performed. During forearm ischemia, Hb-SmO2 declines were recorded for six minutes and correlated (Pearson) between both arms. During the graded treadmill test Hb-SmO2 levels were measured in both gastrocnemius muscles, whereas oxygen consumption and carbon dioxide production were measured by ZAN gas analyzer. The ventilatory threshold (VE) and the deflection point (DP) in the Nirs time series were compared. Results: There were no significant differences between repeated measurements of resting (p>0.05). Significant differences were found in decline slopes of Hb-SmO2 between the different force levels (p

Benzer Tezler

  1. Authentication in wireless sensor networks

    Kablosuz duyarga ağlarında asıllama

    MEHMET ERHAN YİĞİTBAŞI

    Yüksek Lisans

    İngilizce

    İngilizce

    2005

    Bilgisayar Mühendisliği Bilimleri-Bilgisayar ve Kontrolİstanbul Teknik Üniversitesi

    Bilgisayar Mühendisliği Ana Bilim Dalı

    PROF.DR. BÜLENT ÖRENCİK

  2. Comparison of deep learning and conventional receiver design for a NOMA OFDM system

    Bir NOMA OFDM sistemi için derin öğrenme ile geleneksel alıcı tasarımının karşılaştırılması

    RASHEED MOHAMMED ABD ALQAWI ALSHALWE

    Yüksek Lisans

    İngilizce

    İngilizce

    2022

    Elektrik ve Elektronik Mühendisliğiİstanbul Okan Üniversitesi

    Elektronik ve Haberleşme Mühendisliği Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ DİDEM KIVANÇ TÜRELİ

  3. Investigation of maximum wireless power transfer conditions in the near field

    En iyi yakın alan kablosuz güç transferi koşullarının araştırılması

    NURİ TEMÜRLENK

    Yüksek Lisans

    İngilizce

    İngilizce

    2010

    Elektrik ve Elektronik MühendisliğiYeditepe Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    DR. CAHİT CANBAY

  4. Elektrikli araçlarda manyetik rezonans kuplajlı kablosuz enerji transfer sistemi için farklı topolojilerin incelenmesi

    Investigation of different topologies for magnetic resonancecoupling wireless energy transfer system in electric vehicles

    FATMA NUR KARTAL

    Yüksek Lisans

    Türkçe

    Türkçe

    2024

    Elektrik ve Elektronik MühendisliğiSüleyman Demirel Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ ALİ AĞÇAL

  5. 5G mobil teknolojisinin oluşturduğu elektromanyetik alan (EMF) etkisinin belirlenmesi

    Detect of the electromagnetic field (EMF) effect to comprise by5G mobile technology

    AHMET HALİM KÖMÜRCÜ

    Yüksek Lisans

    Türkçe

    Türkçe

    2022

    Elektrik ve Elektronik MühendisliğiMarmara Üniversitesi

    Elektrik ve Elektronik Mühendisliği Ana Bilim Dalı

    PROF. DR. AHMET FEVZİ BABA