Implant bağlantı tipinin, klorheksidinin ve elastomerik tıkayıcıların dinamik koşullarda implant-abutment ara yüzündeki bakteriyel sızdırmazlığa etkisi

Effects of connection geometry and sealant agents on bacterial leakage along the implant-abutment interface:An in vitro study under loaded conditions

  1. Tez No: 484778
  2. Yazar: ARDA ÖZDİLER
  3. Danışmanlar: PROF. DR. FATMA GÜLBAHAR IŞIK ÖZKOL
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Mikrobiyoloji, Dentistry, Microbiology
  6. Anahtar Kelimeler: implant-abutment connection, bacterial leakage, dynamic loading
  7. Yıl: 2017
  8. Dil: Türkçe
  9. Üniversite: İstanbul Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 146

Özet

Bu çalışmanın amacı, dört farklı koniklik açısına sahip (5.4° , 12°, 45°, 60°) implant sistemlerinde, bağlantı tipinin ve sızdırmazlık ürünleri kullanımının dinamik yük altında, bakteriyel sızdırmazlığa olan etkilerinin in-vitro olarak incelenmesidir. Her bir implant sisteminden 21 adet olmak üzere toplamda 84 adet implant-abutment birleşimi çalışmada incelenmiştir (Ankylos Implants Dentsply Almanya, Bego Semados S Implants Bego Almanya, Trias Implants Servo-dental Almanya, DTI Implants DTI Türkiye). Her implant sistemindeki 21 adet örnek, saf bağlantı ( kontrol ), Gluco-Chex (Klorheksidin içerikli sızdırmazlık ürünü) uygulanmış, Kiero Seal (silikon sızdırmazlık ürünü) uygulanmış olacak şekilde (n=7) üçerli alt gruplara ayrılmıştır. Üretici şirketlerin önerileri doğrultusunda, abutment vidalarına ön yükleme torku uygulanmış olup, örnekler 8 mililitrelik Enterococcus faecalis süspansiyonuna parsiyel olarak gömülmüştür. Çiğneme simülatörüne bağlanan her bir örneğe 1.2 Hz dalga boyunda 50 N kuvvette 500.000 siklus çiğneme yükü uygulanmıştır. Örneklerin simülatörden sökülmesini ve bağlantıların açılmasını takiben, implantların iç yivli yüzeylerinden mikrobiyal örnekler alınmış ve uygun kültür ortamında çoğaltılarak sayımları yapılmıştır. Sızdırmanın görülmesi ve sızan bakteri sayıları açısından farklı bağlantı tipleri arasında üç ayrı alt grupta da istatistiksel olarak anlamlı bir farklılık görülmemiştir (p>0.05). Sızan bakteri sayıları açısından sızdırmazlık ürünleri uygulanan gruplar ile kontrol grupları arasında dört farklı bağlantı tipinde de istatistiksel olarak anlamlı farklılıklar gözlemlenmiştir (p

Özet (Çeviri)

The aim of this study was to compare the bacterial leakage of conical internal connection implants with different taper angles (5.4° ,12°,45°,60°) and examine the efficiency of a disinfectant agent and a silicone sealant agent in the prevention of bacterial leakage under loaded conditions. Twenty-one implant–abutment connections were studied from each implant system (Ankylos Implants Dentsply Germany, Bego Semados S Implants Bego Germany, Trias Implants Servo-dental Germany, DTI Implants DTI Turkey) for a total of 84. Each systems' implants were divided into three groups as follows: unsealed (control), 2% Chlorhexidine gel-sealed, silicone-sealed (n=7 for each). The insertion torque was applied to each abutment screw according to manufacturers' recommendation. The specimens were partially immersed in an eight-milliliter E. faecalis suspension. A cyclic load of 50 N was applied for a total of 500,000 cycles at 1.2 Hz to the specimens. Following disconnection of dental implants and abutments, microbial samples were taken from the inner threaded surface of the implants, plated, and counted under appropriate conditions. There were no statistically significant differences in frequency of bacterial leakage and leaked bacterial counts among the four types of connections in all groups (p>0.05). The statistically significant differences were found between sealant agents and control group in four different connection types in terms of the number of leaked bacteria (p0.05) Differences in taper angles in the internal conical connections had no significant effect on leaked bacterial counts and the frequency of bacterial contamination under dynamic loading. As a conclusion the application of 2% chlorhexidine gel or silicone sealant can reduce the leaked bacterial counts along the implant-abutment interface.

Benzer Tezler

  1. Mandibular tam protezleri destekleyen iki farklı implantın çevresindeki marjinal kemik kaybının ve kemik içi stabilite değerlerinin incelenmesi

    Evaluation of the marginal bone loss and stability values of two different implants supporting mandibular complete dentures

    ESMA GEÇKİLİ

    Doktora

    Türkçe

    Türkçe

    2014

    Diş Hekimliğiİstanbul Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. TAYFUN BİLGİN

  2. Dijital ölçü aşamasında kullanılan titanyum ve peek tarama gövde materyallerinin yer değiştirmeye bağlı hassasiyetinin değerlendirilmesi

    Evaluation of displacement precision of titanium and peek scan body materials used in digital impression

    EMRE DİKER

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2021

    Diş HekimliğiAnkara Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. SEDAT HAKAN TERZİOĞLU

  3. CAD/CAM, lazer sinterizasyon ve konvansiyonel döküm yöntemleriyle üretilen metal alt yapıların, implant abutmentlara olan bağlantı dayanımının in vitro olarak karşılaştırılması

    Comparison of connection between metal frameworks and implant abutments produced by CAD/CAM, laser sinterization and conventional casting methods in vitro

    ALİ MUTLU

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2018

    Diş HekimliğiMustafa Kemal Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. MUSTAFA ZORTUK

  4. Dental implant abutmenti - rezin siman bağlantı dayanımı üzerine farklı yüzey pürüzlendirme işlemlerinin etkisinin incelenmesi

    Investigation of the Effect of Different Surface Processes on the Bonding Strength of Dental Implant Abutment ? Resin Cement

    HASAN GÜNGÖR

    Doktora

    Türkçe

    Türkçe

    2010

    Diş HekimliğiAtatürk Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. ZEYNEP YEŞİL DUYMUŞ

  5. Zirkonyum abutment implant bağlantı tiplerinin dinamik ve statik yük altında karşılaştırılması

    Comparison of zirconium abutment implant connection types under dynamic and static loading

    MUALLA AKCA

    Doktora

    Türkçe

    Türkçe

    2014

    Diş HekimliğiÇukurova Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    DOÇ. DR. CEM KURTOĞLU