Atmosferik soğuk plazma uygulamasının peritoneal adezyonun önlenmesi üzerine etkinliğinin araştırılması
Investigation on efficacy of atmospheric cold plasma application for the prevention of peritoneal adhesion
- Tez No: 491807
- Danışmanlar: DOÇ. DR. ENVER İLHAN
- Tez Türü: Tıpta Uzmanlık
- Konular: Genel Cerrahi, General Surgery
- Anahtar Kelimeler: Belirtilmemiş.
- Yıl: 2017
- Dil: Türkçe
- Üniversite: Sağlık Bilimleri Üniversitesi
- Enstitü: İzmir Bozyaka Eğt. ve Arş. Hast.
- Ana Bilim Dalı: Genel Cerrahi Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: 61
Özet
ÖZET GÖKÇELLİ U. (2017), ATMOSFERİK SOĞUK PLAZMA UYGULAMASININ PERİTONEAL ADEZYONUN ÖNLENMESİ ÜZERİNE ETKİNLİĞİNİN ARAŞTIRILMASI Tıpta Uzmanlık Tezi, Sağlık Bilimleri Üniversitesi İzmir Bozyaka Sağlık Uygulama Ve Araştırma Merkezi, Genel Cerrahi Kliniği, İzmir AMAÇ: Abdominopelvik operasyonlardan sonra peritoneal adezyon (PA) oluşumu son derece yaygındır. İskemi, enfeksiyon, kanama gibi faktörlerin neden olduğu patolojik yara iyileşmesi sonucu PA ortaya çıkmaktadır. Atmosferik basınçlı soğuk plazma (ABSP)' nın ise bu faktörlere karşı etkili olduğu bilinmektedir. Bu çalışmada ABSP' nin PA'nın önlenmesi üzerindeki etkisini araştırmayı amaçladık. GEREÇ VE YÖNTEM: Çalışmada 16 adet CD-1 erkek fare kullanıldı. Denekler rastgele olarak iki gruba ayrıldı. Tüm deneklerde çekumda serozal abrazyon ve sağ alt kadrandan pariyetal periton eksizyonu yapılarak adezyon modeli oluşturuldu. Adezyon önleyici bir yöntem uygulanmayanlar Grup I (kontrol grubu) olarak belirlendi. Grup II (plazma grubu)' de ise adezyon modeli oluşturulan alanlara operasyon sırasında 60' ar saniye ABSP uygulandı. Postop 10. gün tüm denekler sakrifiye edildi. Deneklerin tamamında adezyon modeli oluşturulan alanlara makroskopik Knigtly ve Linsky adezyon sınıflamaları yapıldı. Model oluşturulan alanlar bütün olarak eksize edildi ve mikroskopik Zühlke sınıflamasının değerlendirilmesi için patoloji laboratuvarına gönderildi. Sınıflandırma puanları istatistiksel analiz (Mann Whitney-U-test) ile değerlendirildi. BULGULAR: Grup I' de çekuma ait Knightly, Linsky ve Zühlke sınıflamalarının ortalama puanları sırasıyla 2,6; 2,1 ve 2,6 idi. Grup II' de ise ortalama puanlar 0,5; 1,1 ve 1,3 olarak tespit edildi. Buna göre Knightly ve Zühlke sınıflama puanları arasındaki fark Grup II lehine istatistiksel olarak anlamlı bulundu (sırasıyla p=0,015; p=0,018). Grup I' de pariyetal peritona ait Knightly, Linsky ve Zühlke sınıflamaları ortalama puanları sırasıyla 3,3; 3,8 ve 3,4 idi. Grup II' nin ortalama puanları ise 1,6; 1,3 ve 1,5 olarak bulundu. Her 3 sınıflamaya göre de (Knightly, Linsky, Zühlke) gruplar arasındaki fark Grup II lehine anlamlı bulundu (sırasıyla p=0,005; p
Özet (Çeviri)
ABSTRACT GÖKÇELLİ U. (2017), INVESTIGATION ON EFFICACY OF ATMOSPHERIC COLD PLASMA APPLICATION FOR THE PREVENTION OF PERITONEAL ADHESION Dissertation, Health Sciences University Izmir Bozyaka Health Practice and Research Center, General Surgery Clinic AIM: Formation of peritoneal adhesion (PA) is extremely common after abdominopelvic operations. PA emerges as pathological wound healing caused by numerous factors such as ischemia, infection, bleeding. Atmospheric pressure cold plasma (APCP) is known to be effective against those factors. In this study, we aimed to investigate the effect of APCP on prevention of PA. MATERIALS AND METHODS: Sixteen CD-1 male mice were used in the present study. Subjects were randomly divided into two groups. All subjects had serosal abrasion on cecum and an excision model was created by excision of the parietal peritoneum in the lower right quadrant. Group I was determined as control group in which any anti-adhesion method was utilized. In Group II (plasma group), APCP was applied to the areas where the adhesion model was created during the operation for 60 seconds. All subjects were sacrificed on postop day 10. Adhesion level and area were macroscopically evaluated with Knigtly and Linsky scoring. Tissues, on which adhesion were formed, were excised and assessed microscopically using Zühlke scoring method. Evaluation scores were assessed by statistical analysis (Mann Whitney-U-test). RESULTS: The mean scores of Knightly, Linsky and Zühlke classification of cecum were determined as 2.6; 2.1 and 2.6, respectively in Group I. The mean scores were determined as 0.5; 1,1 and 1,3, respectively in Group II. Difference between Knightly and Zühlke classification scores were statistically significant in favor of Group II (p = 0,015, p = 0,018, respectively). The mean scores of Knightly, Linsky and Zuhlke classifications of parietal peritoneum were 3,3; 3.8 and 3.4, respectively in Group I. The mean scores of Group II were 1,6; 1,3 and 1,5. Statistical significance (p = 0.005, p
Benzer Tezler
- Soğuk plazma uygulamasının dental zirkonyanın yüzey özelliklerine ve rezin simanla bağlantısına etkilerinin araştırılması
Evaluation of the effects of non-thermal atmospheric plasma treatment on surface properties and shear bond strength of zirconia ceramics
MERVE ALTUNTAŞ
Diş Hekimliği Uzmanlık
Türkçe
2018
Diş Hekimliğiİzmir Katip Çelebi ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
DR. ÖĞR. ÜYESİ ÖZLEM ÇÖLGEÇEN
- Atmosferik soğuk plazma ve mezenkimal kök hücre ile modifiye edilen titanyum yüzeylerde osteojenik hücreaktivitelerinin değerlendirilmesi
The evaluation of the osteogenic cell activities on titanium surface modified with the atmospheric cold plasma and mesenchymal stem cells
MEHMET BURAK KAPILI
Diş Hekimliği Uzmanlık
Türkçe
2017
Diş Hekimliğiİzmir Katip Çelebi ÜniversitesiAğız Diş ve Çene Cerrahisi Ana Bilim Dalı
YRD. DOÇ. DR. MURAT ULU
- Streptozotosin ile indüklenen diyabetik ratlarda atmosferik soğuk plazma uygulamasının yara iyileşmesi üzerine etkisinin değerlendirilmesi
Assessment of the impact of atmospheric cold plasma application on wound healing in streptozotocin-induced diabetic rats
EMİNE ERSÖZLÜ
Doktora
Türkçe
2024
HemşirelikSağlık Bilimleri ÜniversitesiCerrahi Hastalıkları Hemşireliği Ana Bilim Dalı
PROF. DR. EMİNE İYİGÜN
DOÇ. DR. MUHAMMED KAMİL TURAN
- Atmosferik soğuk plazmanın yüksek ihracat kapasitesine sahip kuru incir ve kuru üzümdeki aflatoksinler ve okratoksin a üzerine etkisi
The effect of atmospheric cold plasma on aflatoxins and ocratoxin a in dried figs and raisins with high export capacity
DUYGU BENZER GÜREL
Doktora
Türkçe
2023
Gıda MühendisliğiManisa Celal Bayar ÜniversitesiGıda Mühendisliği Ana Bilim Dalı
DOÇ. DR. ÖZLEM ÇAĞINDI
- Ratlarda palatal yara modelinde helyum ve argon gazları kullanılarak oluşturulan atmosferik basınçlı soğuk plazma uygulamasının yara iyileşmesine etkisinin değerlendirilmesi
Investi̇gati̇on of argon and heli̇um atmospheri̇c pressure cold plasma appli̇cati̇on on wound heali̇ng i̇n palatal wound model in rats
GÖKHAN CENGİZ
Doktora
Türkçe
2021
Diş HekimliğiSüleyman Demirel ÜniversitesiPeriodontoloji Ana Bilim Dalı
PROF. DR. MİNE ÖZTÜRK TONGUÇ