Çift tüplü bilgisayarlı tomografide çift enerji yöntemi ile elde edilen sanal tek enerji, sanal tek enerji ''plus'' ve birleştirilmiş görüntülerin karotis stent açık kalım takibinde etkinliklerinin karşılaştırılması

Evaluation of dual energy ct methods for carotid stent imaging: Virtual monoenergy, noise-optimized virtual monoenergy and linearly mixed images

  1. Tez No: 496692
  2. Yazar: DİLAN ECE GEYLAN DURGUN
  3. Danışmanlar: DOÇ. DR. HÜSEYİN KORAY KILIÇ
  4. Tez Türü: Tıpta Uzmanlık
  5. Konular: Radyoloji ve Nükleer Tıp, Radiology and Nuclear Medicine
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2018
  8. Dil: Türkçe
  9. Üniversite: Gazi Üniversitesi
  10. Enstitü: Tıp Fakültesi
  11. Ana Bilim Dalı: Radyoloji Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 128

Özet

Karotis stentleme yapılan hastalarda, stent açık kalım takibinde dual enerji BTA incelemelerinde sanal tek enerji, sanal tek enerji ''plus'' ve birleştirilmiş görüntülerin etkinliklerini değerlendirmek. Gereç ve Yöntem Çalışma retrospektif olarak tasarlanmış olup Ekim 2017-Şubat 2018 tarihleri arasında Gazi Üniversitesi Tıp Fakültesi Radyoloji Anabilim Dalı'na başvurarak Dual Enerji BT anjiyografi çekilmiş, tıkayıcı karotis hastalığı bulunan ve stent uygulaması yapılan 13 hasta dahil edilmiştir. Dahil edilen grupta stentlenen karotis arter sayısı 16'dır. BTA incelemesi SOMATOM Force (Siemens Healtcare, Forccheim, Almanya) bilgisayarlı tomografi cihazıyla gerçekleştirilmiştir. İş istasyonlarda birleştirilmiş, sanal tek enerji ve sanal tek enerji ''plus'' görüntüler yeniden yapılandırıldı. Sanal tek enerji ve sanal tek enerji ''plus'' görüntülerde 40-190 keV arasında 10 keV'luk artışlarla görüntüler oluşturuldu. Birleştirilmiş görüntülerde 0,7 oranı kullanıldı (%70 A tüpü, %30 B tüpü). Tüm hastalarda 40-190 keV arasında sanal tek enerji ve sanal tek enerji ''plus'' için 16'şar ve birleştirilmiş görüntüler olmak üzere toplam 33 farklı görüntüde stentli damar lümenine ve komşuluğundaki sternokleidomastoid (SCM) kasına ROI yerleştirilerek Hounsfield Ünitesi (HU) ölçümü yapıldı. ROI'den ortalama HU değeri not edildi. Sinyal-gürültü oranı (SNR) =HU (lümen) / HU (gürültü), kontrast-gürültü oranı ise (CNR) = [HU(lümen) - HU(kas)] / HU(gürültü) olacak şekilde hesaplandı. Verilerin analizi için örneklem sayısının düĢük olması nedeniyle nonparametrik testler kullanıldı. Grup içi tekrarlayan ölçümler için Friedman testi, farkın hangi ölçümden kaynaklandığını bulmak için yapılan ikili eĢleĢtirmelerde Wilcoxon testi kullanıldı. Kategorik verilerin karşılaştırılmasında Ki Kare testi, korelasyon analizleri için ise Spearman Rho analizi yapıldı. Bulgular Çalışmamıza yaşları 55 ile 79 arasında değişen ve ortalama 69,4 olan toplam 13 erkek hastada, 16 stent yerleştirilmiş karotis arter dahil edilmiştir. SNR ve CNR sanal tek enerji (M) görüntülerde en yüksek 70 keV, sanal tek enerji ''plus'' (M+)'ta en yüksek 60 keV'ta bulunmuştur. M 70 keV, M+ 60 keV ve birleştirimiş görüntüler (MIXED) karşılaştırıldığında ise SNR için Mixed değeri, SNR M+60 değerinden anlamlı şekilde daha yüksek iken (p=0,002), MIXED ve M 70 keV arasında anlamlı fark saptanmadı (p=0,098). M 70 keV değeri ise M+ 60 keV değerinden istatistiksel olarak anlamlı şekilde daha yüksekti (p=0,004). CNR için MIXED değeri M 70 keV ve M+ 60 keV değerlerine göre istatistiksel olarak daha yüksekti (sırasıyla p=0,049 ve p=0,003). Ayrıca M+ 60 keV değeri, M 70 keV değerinden istatistiksel olarak anlamlı şekilde daha yüksekti (p=0,014). Korelasyon analizlerinde SNR M 70 keV ile CNR M 70 keV arasında (r=0,993;p

Özet (Çeviri)

Purpose To compare the effectiveness of virtual monoenergy (VMI), noise-optimized virtual monoenergy (VMI+) and linearly mixed images (MIXED) in follow- up of patients who have carotid stents. Material and Methods Institutional review board approved this retrospective study. Thirteen patients with 16 carotid stents, who were on follow-up and scanned with dual energy method between October 2017 and February 2018, were included in this study. VMI, VMI+ and MIXED images were calculated form the same datasets. VMI and VMI+ images were reconstructed between 40-190 keV energy levels with 10 keV increment each. MIXED images reconstructed by linear mixing method with 0,7 ratio: %70 tube A (80kV), %30 tube B (150 Sn kV). Density measurements were made from stent lumen and sternocleidomastoid muscle (SCM) for quantitative comparison. SNR and CNR were calculated as follows: SNR = HU (lumen) / HU (noise); CNR = [(HU (lumen) – HU (SCM)] / HU (noise). Chi-square test was used to compare the categorical data, and Spearman Rho was used to evaluate relationship between variables. The p-value was set to 0,05. Results Highest SNR and CNR levels were achieved at 70 keV in VMI group and at 60 keV in VMI+ group. VMI 70 keV, VMI+ 60 keV and MIXED groups were compared with each other by means of SNR and CNR values. MIXED group's SNR was significantly higher than that of VMI+ 60 keV group (p=0,002). There was no significant difference in SNR between MIXED and VMI 70 keV groups (p=0,098). Significantly best CNR value was calculated in MIXED group (p=0,049 and p=0,003 for VMI 70 keV and VMI+ 60 keV respectively). There was positive correlation between SNR and CNR values (p0,05). Conclusion Dual energy CTA is a noninvasive method for follow up of patients with carotid stents. When three dual energy methods (virtual monoenergy (VMI), noise-optimized virtual monoenergy (VMI+) and linearly mixed images (MIXED)) were compared among each other, MIXED method was found to yield the highest CNR and SNR values.

Benzer Tezler

  1. Mobil telefon kullanımına bağlı oluşan 900-1800 mhz radyo frekans dalgalarının meydana getirdiği elektromanyetik alanın iliak kanat kemik mineral yoğunluğuna etkisi

    The effect of electromagnetic fields on bone mineral density of iliac bone produced by 900-1800 mhz radio frequency waves dependent on cellular phone usage

    BEŞİR ANDAÇ AKSOY

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2006

    Ortopedi ve TravmatolojiSüleyman Demirel Üniversitesi

    Ortopedi ve Travmatoloji Ana Bilim Dalı

    PROF.DR. NEVRES HÜRRİYET AYDOĞAN

  2. Akut pulmoner tromboembolide dual enerji bilgisayarlı tomografi pulmoner anjiografinin tanısal değeri

    The diagnostic value of dual energy computerized tomography pulmonary angiography on acute pulmonary thromboembolism

    NECAT İSLAMOĞLU

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2014

    Radyoloji ve Nükleer TıpSelçuk Üniversitesi

    Radyodiagnostik Ana Bilim Dalı

    YRD. DOÇ. DR. ALİ SAMİ KIVRAK

  3. Kronik koroner arter hastalığı olgularında miyokardiyal canlılığın dual enerjili bilgisayarlı tomografi ile değerlendirilmesi: 3 tesla MRG ile karşılaştırma

    Dual-energy CT for the assessment of chronic myocardial infarction in patients with chronic coronary artery disease: comparison with 3-T MRI

    YEŞİM KIZRAK

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2014

    KardiyolojiAtatürk Üniversitesi

    Radyoloji Ana Bilim Dalı

    PROF. DR. ABDULMECİT KANTARCI

  4. Köpeklerde articulatio cubiti'nin radyolojik ve bilgisayarlı tomografi sonuçlarının teşhis yönünden karşılaştırılması

    Comparison of the results of radiological and computer tomography of knee joints in dogs

    CANAN KONDAK YILMAZ

    Yüksek Lisans

    Türkçe

    Türkçe

    2017

    Veteriner HekimliğiSelçuk Üniversitesi

    Cerrahi (Veterinerlik) Ana Bilim Dalı

    PROF. DR. MUSTAFA ARICAN

  5. Koroner arter hastalığı şüphesi olan hastalarda çok kesitli bilgisayarlı tomografi koroner anjiyografinin prognostik değerinin araştırılması

    Prognostic role of multidetector computed tomography coronary angiography in patients with suspected coronary artery disease

    HİKMET YORGUN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2010

    KardiyolojiHacettepe Üniversitesi

    Kardiyoloji Ana Bilim Dalı

    PROF. DR. M. ALİ OTO