Geri Dön

Kardiyovasküler cerrahi yoğun bakım hastalarında endotrakeal tüp tespitinde kullanılan yöntemlerin aspirasyon sırasındaki hemodinamik değişkenlere etkisi

Effects of the methods used in endotracheal tube fixation on hemodynamic variables during suctionin cardiovascular surgery intensive care patients

  1. Tez No: 507681
  2. Yazar: TUĞBA ÇAM
  3. Danışmanlar: DR. ÖĞR. ÜYESİ GÜLAY ALTUN UĞRAŞ
  4. Tez Türü: Yüksek Lisans
  5. Konular: Hemşirelik, Nursing
  6. Anahtar Kelimeler: Hemodinamik değişkenler, kardiyovasküler cerrahi, endotrakeal aspirasyon, flaster, tüp tutucu, Hemodynamic variables, cardiovascular surgery, endotracheal suction, plaster, tube holder
  7. Yıl: 2018
  8. Dil: Türkçe
  9. Üniversite: Mersin Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Hemşirelik Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 64

Özet

Araştırmada, endotrakeal tüp tespitinde kullanılan yöntemlerin aspirasyon sırasındaki hemodinamik değişkenlere etkisini belirlemek amaçlandı. Yarı deneysel bu araştırmanın örneklemini Eylül 2016-Aralık 2017 tarihleri arasında bir üniversite hastanesinin kardiyovasküler cerrahi yoğun bakım ünitesinde (KVC YBÜ) yatan, entübe 86 hasta oluşturdu. Araştırmada, çalışma grubunun (n=43) endotrakeal tüp (ET) tespiti tüp tutucuyla; kontrol grubunun (n=43) ET tespiti flasterle yapıldı. Hastalara gereksinimleri doğrultusunda endotrakeal aspirasyon uygulandı. Hastaların sistolik kan basıncı (SKB), diyastolik kan basıncı (DKB), kalp atım hızı ve periferik oksijen saturasyonu (SpO2) gibi hemodinamik değişkenleri, aspirasyon öncesi, sırası, bitimi, sonrası 5. ve 15. dk'da ölçüldü. Veri analizinde ki-kare, bağımsız gruplarda t testi, tekrarlı ölçümlerde varyans analizi (ANOVA); çoklu karşılaştırmada Bonferroni-Dunn testi kullanıldı. Araştırmada her iki ET tespit yönteminde de hastaların aspirasyon sırasındaki SKB ve DKB'ı anlamlı olarak yükseldi. Tüp tutucusu kullanılan hastaların flaster kullanılanlardan SKB'ı, aspirasyon sonrası 15.dk'da; DKB'ı ise aspirasyon sırası ve bitiminde anlamlı olarak daha düşüktü. İki ET tespit yönteminde de kalp atım hızı yükselirken, SpO2 değerleri düştü ancak bu değişimler anlamlı değildi. Tüp tutucusu kullanılan hastaların flaster kullanılanlardan SpO2 değeri aspirasyon sırası, bitimi ve sonrası 5. dk da anlamlı olarak daha yüksekti. Her iki ET tespit yönteminin de aspirasyon sırasında kalp atım hızını anlamlı olarak arttırmadığı ve iki yöntem arasında fark olmadığı saptandı. Araştırma bulguları, ET tespitinde kullanılan tüp tutucunun flastere göre endotrakeal aspirasyon sırasında hemodinamik değişkenleri daha az etkilediğini ve KVC YBÜ'nde yatan hastalarda güvenle uygulanabileceğini ortaya koydu.

Özet (Çeviri)

The aim of this research was to determine the effects of the methods used in endotracheal tube fixation on hemodynamic variables during suction. The sample of this semi-experimental research consisted of 86 intubated patients who were hospitalized in the cardiovascular surgical intensive care unit (CVS ICU) of a university hospital between September 2016 and December 2017. In this research, the endotracheal tube (ETT) fixations of the experimental group (n=43) were performed with tube holders while the ETT fixations of the control group (n=43) were performed using plasters. Endotracheal suction was applied in accordance with the patients' needs. Hemodynamic variables such as systolic blood pressure (SBP), diastolic blood pressure (DBP), heart rate and peripheral oxygen saturation (SpO2) of the patients were measured before, during, at the end of and after suction at 5th and 15th minutes. Data were analyzed using Chi-square, independent-samples t-test, repeated measures analysis of variance (ANOVA) andthe Bonferroni-Dunn test for multiple comparisons. In this research, the patients' SBP and DBP levels increased significantly during suction in both ET fixation methods. In comparison with the patients for whom plasters were used for ETT fixation, the patients for whom tube holders were used had significantly lower SBP 15 minutes after suction and significantly lower DBP during and at the end of suction. In both ETT fixation methods, heart rates increased while SpO2 values decreased, but these changes were not significant. The patients with tube holder had significantly higher SpO2 values than the patients with plaster during, at the end of and 5 minutes after suction. It was determined that neither ETT fixation methods significantly increased heart rate during suction and there was no difference between the two methods in this regard. The results also revealed that tube holders used for ETT fixation had less effect on hemodynamic variables during endotracheal suction compared to plasters, and that they could be applied safely to patients hospitalized in CVS ICU.

Benzer Tezler

  1. Yoğun bakımda sedasyon uygulanmasında midazolam ile midazolam ve magnezyum kombinasyonunun etkinliklerinin karşılaştırılması; bispektral indeks monitörizasyonu ile klinik sedasyonskorları arasındaki korelasyonundeğerlendirilmesi

    Comparison of the activities of midazolam and midazolam and magnesium combinations in intensive care unit sedation implementation; evaluation of correlation bispectral index monitorization between clinical sedationscores

    DİLEK ALTUN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2010

    Anestezi ve ReanimasyonSağlık Bakanlığı

    Anesteziyoloji ve Reanimasyon Ana Bilim Dalı

    DOÇ. DR. ZAFER ÇUKUROVA

  2. Bir devlet hastanesinde açık ve kapalı sistem aspirasyon yöntemleri için standart geliştirilmesi ve bu yöntemlerin hastaların hemodinamik durumuna etkisinin belirlenmesi

    Developing standard for the methods of open and closed system suctioning and determination of influence of this methods to hemodynamic status of patients in a state hospital

    DİLEK ÖZDEN

    Doktora

    Türkçe

    Türkçe

    2007

    HemşirelikHacettepe Üniversitesi

    Hemşirelik Esasları Ana Bilim Dalı

    PROF.DR. R. SELMA GÖRGÜLÜ

  3. Kaflı kafsız entübasyon uygulanan yenidoğanların bakımında enteral beslenmenin değerlendirilmesi

    Evaluation of enteral nutrition in newborn intubated with cuffed and cuffless tube

    BUSE DUYGU YÜKSEL

    Yüksek Lisans

    Türkçe

    Türkçe

    2019

    Hemşirelikİstanbul Medipol Üniversitesi

    Hemşirelik Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ AYSEL KÖKCÜ DOĞAN

  4. Endotrakeal aspirasyonda serum fizyolojiğin etkileri

    Effects of saline solution on endotracheal suctioning

    SEVİM AKGÜL

    Yüksek Lisans

    Türkçe

    Türkçe

    2000

    Genel Cerrahiİstanbul Üniversitesi

    Cerrahi Hastalıkları Hemşireliği Ana Bilim Dalı

    DOÇ.DR. NERİMAN AKYOLCU

  5. Endotrakeal entübasyon uygulanan hastalarda aspirasyon standardı

    The Standard of suction for patients having endotracheal intubation

    SEVİLAY ŞENOL

    Doktora

    Türkçe

    Türkçe

    1998

    HemşirelikHacettepe Üniversitesi

    Hemşirelik Ana Bilim Dalı

    DOÇ. DR. NALAN ÖZHAN ELBAŞ