Valsartan, vilazodon hidroklorür ve karışımları ile oluşturulan metal komplekslerinin spektrofotometrik olarak incelenmesi
Spectrophotometric investigation of metal complexes formed out with valsartan, vilazodon hydrochloride and their mixture
- Tez No: 510585
- Danışmanlar: DR. ÖĞR. ÜYESİ SERAP KARADERİ
- Tez Türü: Yüksek Lisans
- Konular: Eczacılık ve Farmakoloji, Pharmacy and Pharmacology
- Anahtar Kelimeler: Belirtilmemiş.
- Yıl: 2018
- Dil: Türkçe
- Üniversite: Marmara Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Analitik Kimya Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: 93
Özet
Amaç: Valsartan, Vilazodon Hidroklorür ve karışımları ile Cu(II), Ca(II), Cd(II), Mg(II) ve Zn(II) metal iyonları arasında meydana gelen komplekslerin, stokiyometrik oranlarının mol oran yöntemi ile belirlenerek, doğru, sağlam, hızlı, basit ve düşük maliyetli bir UV-Vis spektrofotometrik yöntem geliştirmektir. Gereç ve Yöntem: Bu çalışmada, Valsartan, Vilazodon hidroklorür ve karışımlarının ayrı ayrı ve Cu(II), Ca(II), Cd(II), Mg(II) ve Zn(II) metal iyonları arasında meydana gelen kompleksler için ultraviyole-görünür bölgede spektrumları alındı. Ayrıca, Valsartan ve Vilazodon Hidroklorür'ün Cu(II), Ca(II), Cd(II), Mg(II) ve Zn(II) arasında oluşturacakları komplekslerin stokiyometrik oranı mol oran yöntemi kullanılarak belirlendi. Yöntemin uygunluğu, validasyon parametreleri tarafından test edildi. Bulgular: Valsartan ve Vilazodon Hidroklorür için sırasıyla, 2,20-10,89 µg/mL ve 2,4-12,0 µg/mL konsantrasyon aralığında doğrusal olduğu bulundu. Mol oran yöntemine göre, Vilazodon Hidroklorür'ün Cu(II), Ca(II), Cd(II), Mg(II) ve Zn(II) metal iyonları arasında oluşturduğu komplekslerin stokiyometrisi 1:1, Valsartan'ın Cu(II), Ca(II), Cd(II), Mg(II) metal iyonları arasında oluşan kompleksin stokiyometrisi 1:1 fakat Zn(II) metal iyonu ile oluşturduğu kompleks 1:2 olarak tayin edildi. Vilazodon Hidroklorür'ün geri kazanımı %97,1, Valsartan'ın geri kazanımı %92,0-97,5 aralığında bulundu. Sonuçlar: Geliştirilen UV-Vis spektrofotometrik yöntemin, kesin, tekrarlanabilir ve doğru olduğu tespit edildi ve benzer ilaç etken maddelerin metal kompleks çalışmalarında başarı ile uygulanabilir ekonomik bir yöntem olarak düşünülmektedir. Valsartan ve Vilazodon Hidroklorür ile metal iyonları arasında oluşan komplekslerin tedaviye olumlu veya olumsuz etki göstereceği düşünülmektedir.
Özet (Çeviri)
Aim: Developing a accurate, safe, fast, simple and low-cost UV-Vis spectrophotometric method by determining the complexes occured between Valsartan, Vilazodone Hydrochloride and their mixtures and Cu(II), Ca(II), Cd(II), Mg(II) and Zn(II) metal ions and their stoichiometric ratios with using mole ratio method. Material and Method: In this study, the separately spectrums of Valsartan, Vilazodon Hydrochloride and their mixtures and the complexes occured between Cu(II), Ca(II), Cd(II), Mg(II) and Zn(II) metal ions were taken in ultra-violet area. In addition, stoichiometric ratios of the complexes occured between Valsartan and Vilazodone Hydrochloride with Cu(II), Ca(II), Cd(II), Mg(II) and Zn(II) metal ions were determined using mole ratio method. Findings: For Valsartan and Vilazodon Hydrochloride respectively, it was found that they are linear between 2.20-10.89 µg/mL and 2.4-12.0 µg/mL concentration range. According to mole ratio method, the stoichiometry of the complexes between Vilazodone Hydrochloride and the metal ions of Cu(II), Ca(II), Cd(II), Mg(II) and Zn(II) is 1:1; the stoichiometry of the complexes between Valsartan and the metal ions of Cu(II), Ca(II), Cd(II), Mg(II) is 1:1, however the complex of the metal ion of Zn (II) is determined as 1:2. The percentage recovery for the Vilazodon hydrochloride and Valsartan were found 97.1 % and 92-97.5 %, respectively. Results: It was determined that the develop UV-Vis spectrophotometric method was precision, reproducible and accurate and it is considered that it is a successfully applicaple low-cost method in the metal complex studies of both drug active ingredients. It is considered that the complexes between Valsartan and Vilazodone Hydrochloride's with metal ions would affect treatments positively or negatively.
Benzer Tezler
- Valsartan/sakubitril kombinasyonu LCZ696'nın diabetik kardiyak disfonksiyon üzerine olası etkilerinin beta adrenerjik yanıtverirlik üzerinden değerlendirilmesi
The evaluation of possible effects of valsartan/sacubitril combination LCZ696 on diabetic cardiac dysfunction in terms of β-adrenergic responsiveness
BETÜL RABİA ERDOĞAN
Doktora
Türkçe
2020
Eczacılık ve FarmakolojiAnkara ÜniversitesiFarmakoloji Ana Bilim Dalı
DOÇ. DR. EBRU ARIOĞLU İNAN
- Bazı ARA-II bileşiklerinin (Anjiyotensin reseptör antagonistlerinin) metal bağlama özelliklerinin spektroflorimetrik yöntemle incelenmesi
Investigation of the metal bonding properties of some ARA-II (Angiotensin II receptor antagonists) compounds using spectrofluorimetric method
AHMET DÖNERTAŞ
Yüksek Lisans
Türkçe
2015
KimyaSelçuk ÜniversitesiAnalitik Kimya Ana Bilim Dalı
DOÇ. DR. SELMUŞ BENİZ GÜNDÜZ
- Valsartan ve klortalidon'un yüksek performanslı sıvı kromatografisi yöntemi ile tabletlerde yan yana analizi
Simultaneous determination of valsartan and chlorthalidone in tablets by using high-performance liquid chromatographic method
ZEYNEP DERYA BİLGİN
Yüksek Lisans
Türkçe
2024
Eczacılık ve Farmakolojiİstanbul ÜniversitesiAnalitik Kimya Ana Bilim Dalı
PROF. DR. SIDIKA TOKER
- Valsartan içeren kombine antihipertansif tedavi alan gerçek yaşam ortamındaki ve randomize kontrollü çalışmalardaki popülasyonların karşılaştırılması
Comparison of populations in REAL-life environment and randomized controlled studies receiving combined antihypertensive treatment containing valsartan
GÖKTÜRK ÖTÜNÇ
Doktora
Türkçe
2021
Eczacılık ve Farmakolojiİstanbul ÜniversitesiTıbbi Farmakoloji Ana Bilim Dalı
PROF. DR. ALİ YAGIZ ÜRESİN
- Valsartan'ın elektrokimyasal davranışının incelenmesi ve tayini için anodik adsorptif sıyırma yönteminin geliştirilmesi
İnvestigation of electrochemical behaviors of Valsartan and development of anodic adsorptive stripping voltammetric method to its determination
NEDİM GÜRLER