Deneysel femur kırığı oluşturulan ratlarda biyokompozit kaplı intramedullar pinlerin biyouyum ve kırık iyileşmesi üzerine etkilerinin araştırılması
Investigation of biocomposite coated intramedullary rods effects on biocompatibility and fracture healing in experimental femur fractured rats
- Tez No: 518860
- Danışmanlar: PROF. DR. RAMAZAN GÖNENCİ, PROF. DR. İBRAHİM CANPOLAT
- Tez Türü: Doktora
- Konular: Veteriner Hekimliği, Veterinary Medicine
- Anahtar Kelimeler: Belirtilmemiş.
- Yıl: 2018
- Dil: Türkçe
- Üniversite: Hatay Mustafa Kemal Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Cerrahi (Veterinerlik) Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: 129
Özet
Bu çalışma ile; hidroksiapatit (HA), hegzagonal bor nitrür (h-BN), kitosan (Cs) ve tip 1 kollajen (Ct1) içeriği ile yeni oluşturulan bir biyokompozitle kaplanan intramedullar pinlerin deneysel femur kırığı oluşturulan ratlarda biyouyumluluk ve kırık iyileşmesi üzerine etkilerinin araştırılması amaçlanmıştır. Çalışma kapsamında Wistar albino ırkı, 300-500 g aralığında ağırlığa sahip toplam 60 adet erişkin erkek rat kullanıldı. Ratlar, A (kaplamasız) ve B (biyokompozit kaplamalı) implant uygulanmak üzere rastgele iki gruba ayrıldı. Femur'a lateral yaklaşım ile ulaşılarak diyafizer transvers kırık oluşturuldu. Paslanmaz çelik ve biyokompozit (HA/h-BN/Cs/Ct1) kaplamalı paslanmaz çelik implantlar intramedullar pin olarak retrograd yöntemle uygulandı. Bu gruplar da sakrifikasyon tarihlerine göre A1 ve B1 (15.gün), A2 ve B2 (30.gün), A3 ve B3 (45.gün) alt gruplarına ayrıldı. Postoperatif ilk hafta pansuman ve antibiyotik uygulamaları yapıldı. Elde edilen klinik, radyografik, hematolojik, biyokimyasal ve histopatolojik bulgular karşılaştırmalı olarak değerlendirildi. Kaplamasız ve biyokompozit kaplamalı implant uygulamalarının bulguları alt gruplar arasında karşılaştırıldığında; klinik, radyografik, hematolojik ve histopatolojik veriler birbiri ile tutarlı ve benzer bulundu. Biyouyumluluğu bozan bir bulguya dair istatistiksel anlamlı fark bulunamadı. Histopatolojik incelemelerde kaplama biyomalzemesinin 15, 30 ve 45 günlük süreçlerde rezorbe olmadığı görüldü. Biyokimyasal incelemelerde özellikle kallus oluşumu dönemine işaret eden A2-B2 alt grupları karşılaştırıldığında; B2 alt grubunun ALP ve ALT değerlerinin istatistiksel olarak anlamlı derecede daha yüksek iken CK, LDH, Cr ve BUN değerlerinin ise daha düşük olması biyokompozit kaplamalı implantların olumlu etkilerinin en yoğun olarak bu dönemde ortaya çıktığını göstermiştir. Biyomalzeme içeriğinin biyouyumlu olduğu böylece ortaya konmuştur. Ancak, kaplama yüzeyinin sterilizasyon ve cerrahi işlemlere karşı fiziksel dayanıklılığının artırılmasının elzem olduğu sonucuna varıldı. Sonuç olarak; biyokompozit kaplamalı paslanmaz çelik implantların kemiğe intramedullar uygulamasında biyouyumluluk gösterdiği; klinik, radyografik, hematolojik, biyokimyasal ve histopatolojik bulguların yorumlanmasına dayanarak belirlendi. Kırık iyileşmesini olumsuz etkileyen veya biyouyumu bozan sistemik veya lokal bir reaksiyona yol açmadığı görüldü. Bununla birlikte kısa vadede kırık iyileşmesini önemli veya belirgin miktarda artıran veya hızlandıran bir etkiye sahip olmadığı sonucuna varıldı.
Özet (Çeviri)
In this study; it was aimed to investigate the effects of intramedullary pins coated with a newly formed biocomponent of hydroxyapatite (HA), hexagonal boron nitride (h-BN), chitosan (Cs) and type 1 collagen (Ct1) on biocompatibility and fracture healing in experimental femur fractured rats. A total of 60 adult male Wistar rats weighing 300-500 g were used in the study. The rats were randomly divided into two groups for implantation of A (uncoated) and B (biocomposite coated) implants. The diaphyseal transverse fracture was achieved by reaching the femur via lateral approach. Stainless steel and biocomposite (HA/h-BN/Cs/Ct1) coated stainless steel implants were used retrogradely as intramedullary pins. These groups were divided into subgroups A1 and B1 (15th day), A2 and B2 (30th day), A3 and B3 (45th day) according to the date of sacrification. In the first postoperative week, dressings and antibiotics were applied. Clinical, radiographic, hematological, biochemical and histopathological findings were evaluated comparatively. When the findings of uncoated and biocomposite coated implants were compared among subgroups; clinical, radiographic, hematological and histopathologic findings were consistent and similar. No statistically significant difference was found for a finding that disturbed biocompatibility. Histopathological examinations showed that coating biomaterials did not resorbe during 15, 30 and 45 days. Compared with A2-B2 subgroups, which especially point to the callus formation period in biochemical examinations, the B2 subgroup showed higher ALP and ALT values at a statistically significant level, while CK, LDH, Cr and BUN values were lower, indicating that positive effects of biocomposite coated implants occurred most intensively during this period. It is thus revealed that biomaterial's content is biocompatible. However, it has been concluded that it is necessary to increase the physical strength of the coating surface against sterilization and surgical procedures. As a result; based on interpretations of the clinical, radiographic, hematological, biochemical and histopathological findings, the biocomposite coated stainless steel implants were determined show biocompatibility in intramedullary application to the bones. It did not lead to a systemic or local reaction that adversely affected fracture healing or disturbed the biocompatibility. Nevertheless, it was concluded that it did not have an effect to increase or accelerate fracture healing in any important or significant amount.
Benzer Tezler
- Kirenol'ün ratlarda deneysel femur kırığı kaynaması ve WNT/ β-catenin yolağı üzerine etkileri
Effects of Kirenol on experimental fracture healing and Wnt/ β-catenin pathway
ALİ ERAY GÜNAY
Tıpta Uzmanlık
Türkçe
2017
Eczacılık ve FarmakolojiErciyes ÜniversitesiOrtopedi ve Travmatoloji Ana Bilim Dalı
DOÇ. DR. İBRAHİM KARAMAN
- Ratlarda deneysel olarak açık femur kırığı zemininde oluşturulan osteomiyelit modelinde farklı oranlardaki hidroksiapatit ve/veya bor nitrür'ün etkilerinin araştırılması
The effects of boron nitride and/or hydroxyapatite compounds on experimentally induced osteomyelitis following open femoral fracture in rats
IRMAK FERAH
Doktora
Türkçe
2015
Eczacılık ve FarmakolojiAtatürk ÜniversitesiTıbbi Farmakoloji Ana Bilim Dalı
PROF. DR. ZEKAİ HALICI
- Favipravir ilaç uygulamasının ratlarda femur cisim kırığı kaynaması üzerine etkisi
The effect of favipiravir drug administration on union of femoral shaft fracture in rats
MEHMET ALİ SABIR
Tıpta Uzmanlık
Türkçe
2022
Ortopedi ve TravmatolojiTrakya ÜniversitesiOrtopedi ve Travmatoloji Ana Bilim Dalı
PROF. DR. CEM ÇOPUROĞLU
- Traneksamik asitin lokal ve intravenöz uygulanmasının tibia fraktürlerinin kaynaması üzerine etkilerinin değerlendirilmesi:Deneysel çalışma
The effects of local and intravenous tranexamic acid administration on tibia fracture healing:Experimental study
BAHADIR BALKANLI
Tıpta Uzmanlık
Türkçe
2018
Ortopedi ve TravmatolojiTrakya ÜniversitesiOrtopedi ve Travmatoloji Ana Bilim Dalı
PROF. DR. CEM ÇOPUROĞLU
- Kedilerde supracondylar femur kırıklarının deve kemiğinden elde edilen pinlerle sağaltımı
The treatment of the supracondylar femur fracture with bone pins which were made from camel in cats
MEHMET UĞUR DABANOĞLU