Meme kanseri radyoterapisinde set-up hataları üzerine etkili faktörler

Factors affecting set-up errors in breast cancer radiotherapy

  1. Tez No: 519702
  2. Yazar: SEHER TERCAN
  3. Danışmanlar: DOÇ. DR. ŞÜKRİYE BİLGE GÜRSEL
  4. Tez Türü: Yüksek Lisans
  5. Konular: Fizik ve Fizik Mühendisliği, Onkoloji, Physics and Physics Engineering, Oncology
  6. Anahtar Kelimeler: Meme kanseri, Radyoterapi, Set-up, Kayma, Portal görüntüleme, Breast cancer, Radiotherapy, Set-up, Shift, Portal imaging
  7. Yıl: 2018
  8. Dil: Türkçe
  9. Üniversite: Ondokuz Mayıs Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Radyolojik Bilimler Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 63

Özet

Amaç: Meme koruyucu cerrahi yapılan meme kanserli hastaların, yaş, boy, kilo, meme boyut ve hacmi gibi faktörlerinin, radyoterapi sırasındaki set-up hataları üzerine etkisinin belirlenmesini ve korelasyon oranlarının ortaya konmasını amaçladık. Materyal ve Metot: Kliniğimize başvuran meme koruyucu cerrahi yapılmış ve radyoterapi endikasyonu konmuş 34 meme kanseri tanılı kadın hastanın tedavi planı ve tedavi sırasındaki portal görüntülemelerle set-up kontrolleri kliniğin rutin uygulama prensipleri kapsamında aynı şekilde yapıldı. Bu hastaların tedavi başlangıcında yaşı, boyu, kilosu, meme hacmi gibi kişisel faktörleri kayıt edildi. Hastalara ait bu özellikler ile port film sayıları, kayma değerleri arasındaki korelasyon SPSS paket programı yardımı ile Pearson korelasyon testi ile değerlendirildi. Bulgular: Çalışmamıza dahil edilen hastaların ortalama kaymaları, bir set-up da çekilen ortalama port sayıları, her bir set-up'da çekilen en çok port sayısı, toplam çekilen port sayısı kaydedildi. Ortalama set-up kaymaları ile hastanın yaş, boy, kilo, meme boyut ve hacmi gibi faktörler arasındaki korelasyon incelendiğinde meme hacmi ve meme genişliğinin lateral kayma ile istatistiki anlamlı pozitif korele olduğu izlendi. Sonuç: Hastanın vücut ağırlığı, meme hacmi ve meme ölçülerinin büyüklüğü tedavinin uygulanabilirliğini sağlamak için daha çok toplamda portal görüntüleme alınması gerekliliği doğurmaktadır. Hastanın ağırlığı, meme hacmi ve genişliğinin fazla olması, lateral pandulasyonlarla en çok lateral eksende kayma farkına yol açmaktadır.

Özet (Çeviri)

Aim: We aimed to determine the effect of factors such as age, height, weight, breast size and volume on the set-up errors during radiotherapy and to determine the correlation rates of patients with breast cancer who underwent breast conserving surgery. Material and Method: The treatment plan of 34 women with breast cancer who had undergone breast conserving surgery and radiotherapy indications applied to our clinic, and the portal imaging and set-up controls during treatment were performed in the same way as the routine practice principles of the clinic. Personal factors such as age, height, weight, and breast volume were recorded at the beginning of treatment for these patients. The correlations between these features and port film counts and slip values were evaluated by Pearson correlation test with the help of SPSS package program. Results: The mean shifts of the patients included in the study, the average number of ports taken in a set-up, the maximum number of ports taken in each set-up, and the total number of ports taken were recorded. When the correlation between mean set-up shifts and age, height, weight, breast size and volume were examined, it was observed that breast volume and breast width were correlated positively with lateral slip. Conclusion: Increased body weight, breast volume and measurents of breast are factors that necessitates more portal imaging in total to ensure the feasibility of treatment. The weight of the patient, the volume of the breast and the excess of the width, leads to the lateral deviation of the lateral axis with lateral pandulations.

Benzer Tezler

  1. Meme kanseri radyoterapisinde 3 boyutlu bilgisayarlı planlama ve dozimetrik sürecin randofantom üzerinde termolüminesans dozimetri ile kontrolü

    Control of dosimetric process and 3D computer-based treatment planning system with thermoluminescence dosimeters (TLD) at the randophantom, in breast radiotherapy.

    ABDULLAH YEŞİL

    Yüksek Lisans

    Türkçe

    Türkçe

    2009

    Fizik ve Fizik MühendisliğiUludağ Üniversitesi

    Radyasyon Onkolojisi Ana Bilim Dalı

    DOÇ. DR. LÜTFİ ÖZKAN

  2. Tanjansiyel meme ışınlamasında tek merkezli izosentrik yarım alan tekniğinin dozimetrik incelemesi

    Dosimetric analysis of mono isocentric half beam technique in tangential breast irradiation

    MUSTAFA DOĞAN

    Yüksek Lisans

    Türkçe

    Türkçe

    2014

    OnkolojiTrakya Üniversitesi

    Sağlık Fiziği Ana Bilim Dalı

    PROF. DR. MUSTAFA CEM UZAL

  3. Sol meme kanseri radyoterapisinde tanjansiyel yoğunluk ayarlı ve alan içinde alan tedavi planlama tekniklerinin convolution algoritması ile hesaplanarak dozimetrik açıdan karşılaştırılması

    Dosimetric comparison of tangential intensity modulated and field in field treatment planning techniques in left breast cancer radiotherapy by calculating with convolution algorithm

    KADİR DAĞ

    Yüksek Lisans

    Türkçe

    Türkçe

    2023

    Radyasyon Onkolojisiİstanbul Aydın Üniversitesi

    Sağlık Fiziği Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ FÜSUN ÇETİN

  4. Meme kanseri radyoterapisinde TLD ölçümleri ve plan verileri karşılaştırılarak solunum hareketlerinin cilt dozu üzerine etkisinin değerlendirilmesi

    Assessment of the effect of breathing movements on the skin dose by comparison of TLD measurements and plan data in breast cancer radiotheraphy

    DEMET ERGÜN

    Yüksek Lisans

    Türkçe

    Türkçe

    2018

    Fizik ve Fizik MühendisliğiAnkara Üniversitesi

    Medikal Fizik Ana Bilim Dalı

    PROF. DR. AYŞE KAŞKAŞ

    YRD. DOÇ. DR. SÜHEYLA AYTAÇ ARSLAN