Geri Dön

Setirizin etkin maddesine sahip farmasötik preparatlarda biyoanalitik yöntem validasyonu

Bi̇oanalyti̇cal method vali̇dati̇on i̇n pharmaceuti̇cal preparati̇ons contai̇ni̇ng ceti̇ri̇zi̇ne

  1. Tez No: 533791
  2. Yazar: OĞUZHAN SAVAŞ
  3. Danışmanlar: PROF. DR. YÜCEL KADIOĞLU
  4. Tez Türü: Yüksek Lisans
  5. Konular: Eczacılık ve Farmakoloji, Pharmacy and Pharmacology
  6. Anahtar Kelimeler: Setirizin dihidroklorür, UV-Görünür Bölge Spektroskopisi, HPLC, Zorlanmış Degradasyon, Cetirizine dihidrochloride, UV-Visible Spectroscopy, HPLC, Forced Degradation
  7. Yıl: 2019
  8. Dil: Türkçe
  9. Üniversite: Atatürk Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Analitik Kimya Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 73

Özet

Amaç. Farmasötik preparatlarda Setrizinin belirlenmesi için iki analitik yöntemin geliştirilmesi, geçerlilik testlerinin yapılması, Setrizin içeren farmasötik prepatlarda miktar analizinin gerçekleştirilmesi ve hazırlanan Setrizin standart çözeltilerinin değişik bozundurma ortamlarında geri kazanım ile stabilite değerlerinin belirlenmesi amaçlanmıştır. Materyal ve Metot. UV-Görünür Bölge spektrofotometrik ölçümler için optimum dalga boyu 247 nm olarak belirlendi ve ölçümler 200-350 nm dalga boyu aralığında gerçekleştirildi. HPLC-UV analizleri için optimum kromatografik koşullar metanol/ACN/TFA Su (30/25/45, v/v/v) oluşan mobil faz, 10 µl enjeksiyon hacmi, 1ml/dak akış hızı, C18 (250x4,6 mm,5µm ) kromatografik kolon ile izokratik elüsyon sistemi olarak belirlendi. Bulgular. UV-Görünür bölge spektrofotometri yöntemi için doğrusal aralık 5-100 µg/mL olarak belirlendi. Yöntemin geçerlilik testleri yapıldı. Standart çalışma çözeltileriyle yapılan gün içi analizlerde kesinlik ve doğruluk değerleri sırasıyla %0,85 ve % 0,89 değerlerinin altındaydı. Günler arası ölçümlerde ise kesinlik ve doğruluk değerleri sırasıyla %1,33 ve %-1,45 değerlerinin altında bulundu. HPLC-UV yönteminde doğrusal çalışma aralığı 1-30 µg/mL olarak belirlendi. Yönteminin validasyon çalışmasında standart çalışma çözeltileri ile yapılan analizlerde gün içi kesinlik ve doğruluk değerleri sırasıyla %3,48 ve %-5,72'nin altında, günler arası ölçümlerde ise kesinlik ve doğruluk değerleri sırasıyla %4,44 ve %-3,05 değerlerinin altıda bulundu. Stabilite testleri için Setrizin etken maddesinin farklı degredasyon koşulları altında stabilitesi geri kazanım yöntemiyle belirlendi. Sonuç. Setrizin için geliştirilen ve valide edilen spektrofotometrik ve HPLC-UV yöntemleri farmasötik preparatta Setrizin analizinde başarı ile uygulandı. Setrizinin yüksek asidik ve bazik ortamlarda ve özellikle oksidasyon ortamında stabil olmadığı belirlendi. Geliştirilen yöntemlerin farmasötik endüstride kalite kontrol çalışmalarında ve deneysel araştırmalarda uygulanabilir olduğu kanaatindeyiz.

Özet (Çeviri)

Aim. The aim of this study is developing two analytical methods for determining cetrizine in pharmaceutical preparations, validation of analytic methods, quantity analysis of pharmaceutical preparations containing cetrizine and determination of recovery and stability values of standard solution of cetirizine under different degradation environments . Materials and Methods. The optimum wavelength for UV-Visible spectrophotometric measurements was 247 nm and the measurements were performed in the 200-350 nm wavelength range. Optimum chromatographic conditions for HPLC-UV analysis were defined as methanol/ACN/TFA mobile phase consisting of water (30/25/45, v/v/v), 10 µl injection volume, 1ml/min flow rate, C18 (250x4,6 mm, 5 µm) chromatographic column and isocratic elution system. Results. The linear range for UV-Visible spectrophotometry method was determined as 5-100 µg/mL. The validity tests of the method were performed. İn daily analysis with standard working solutions, the accuracy and precision values were below the values of 0.85% and 0.89%, respectively. In measurements between days the accuracy and precision values were below the values of 1.33% and -1.45%, respectively. The linear working range was determined as 1-30 µg / mL in HPLC-UV method. In the validation study of the method, daily analysis with standard working solutions, the accuracy and precision values were below the values of 3,48% and -5,72%, respectively and between days the accuracy and precision values were below the values of 4.44% and -3.05%, respectively. Stability of cetirizine under different degradation conditions for stability tests was determined by recovery method. Conclusion. The spectrophotometric and HPLC-UV methods developed and validated for setrizin were successfully applied in the pharmaceutical preparation in the cetrizine analysis. It was determined that the cetrizine was not stable in high acidic and basic environments and especially in oxidation environment. We believe that developed methods can be applied in quality control studies and experimental studies in pharmaceutical industry.

Benzer Tezler

  1. Antihistaminik levosetirizin dihidroklorür'ün sitogenetik markerlar üzerine etkileri

    The effects of antihistamine levocetirizine dihydrochloride on cytogenetic markers

    HÜSNİYE SEVTAP KUTLU

    Yüksek Lisans

    Türkçe

    Türkçe

    2019

    BiyolojiKahramanmaraş Sütçü İmam Üniversitesi

    Biyoloji Ana Bilim Dalı

    PROF. DR. AHMET KAYRALDIZ

  2. Antihistaminik ilaçların drosophila melanogaster gelişimi üzerine etkileri

    Effects of antihistamine drugs on the development of drosophila melanogaster

    EBRU ÇUHADAR

    Yüksek Lisans

    Türkçe

    Türkçe

    2024

    BiyolojiSakarya Üniversitesi

    Biyoloji Ana Bilim Dalı

    PROF. DR. HÜSEYİN AKSOY

  3. Coupling ozone with GAC, AIX and biochar: Removal of pharmaceuticals from the biologically treated wastewater and fate of their transformation products

    Ozonun granüler aktif karbon, iyon değişimi veya biyokömürle kombinasyonu ile farmasötiklerin biyolojik arıtılmış atıksudan giderilmesi ve transformasyon ürünlerinin akıbeti

    MALHUN FAKIOĞLU KUTLU

    Doktora

    İngilizce

    İngilizce

    2024

    Çevre Mühendisliğiİstanbul Teknik Üniversitesi

    Çevre Mühendisliği Ana Bilim Dalı

    PROF. DR. İZZET ÖZTÜRK

  4. Yeni nesil antihistaminik ilaçlar ve koruyucu maddelerin hplc ile çeşitli farmasötik preparatlardan yan yana tayinleri

    Simultaneous determination of new generation histamine blockers and preservatives in various pharmaceutical preparations by hplc

    İKBAL SARIKAYA YILDIZ

    Yüksek Lisans

    Türkçe

    Türkçe

    2024

    Eczacılık ve Farmakolojiİstanbul Üniversitesi

    Analitik Kimya Ana Bilim Dalı

    PROF. DR. SENA ÇAĞLAR ANDAÇ

  5. Highway traffic classification using data mining in machine learning

    Başlık çevirisi yok

    KHALID FARHAN MOHAMMED MOHAMMED

    Yüksek Lisans

    İngilizce

    İngilizce

    2020

    Bilgisayar Mühendisliği Bilimleri-Bilgisayar ve KontrolAltınbaş Üniversitesi

    Bilgi Teknolojileri Ana Bilim Dalı

    PROF. DR. OSMAN NURİ UÇAN