Toraks bilgisayarlı tomografi taraması yapılan hastalarda tiroid gland ve orbitaların maruz kaldığı yüzey dozlarının iki farklı cihazda dozimetrik yöntemlerle belirlenmesi ve karşılaştırılması

Determination and comparison of thyroid gland and orbital surface doses that exposed to radiation in patients undergoing thorax computed tomography in TWO different devices by dosimetric methods

  1. Tez No: 544062
  2. Yazar: SEMRA ARSLAN
  3. Danışmanlar: DR. ÖĞR. ÜYESİ HÜSEYİN ÇETİN
  4. Tez Türü: Yüksek Lisans
  5. Konular: Fizik ve Fizik Mühendisliği, Radyoloji ve Nükleer Tıp, Physics and Physics Engineering, Radiology and Nuclear Medicine
  6. Anahtar Kelimeler: Bilgisayarlı tomografi, CTDIvol, DLP, TLD-100 dozimetre, yüzey dozu, Computed tomography, CTDIvol, DLP, TLD-100 dosimetry, surface dose
  7. Yıl: 2019
  8. Dil: Türkçe
  9. Üniversite: Ankara Yıldırım Beyazıt Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Radyoloji Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 123

Özet

Bu çalışmada iki farklı bilgisayarlı tomografi cihazında, her bir cihazda 50 hasta olmak üzere toplamda 100 hastada tiroid gland, sağ göz ve sol göz yüzeyinden doz ölçümleri alınmıştır. Dozimetrik ölçümlerde TLD-100 dozimetreleri kullanılmıştır. Toraks tomografi taraması yapılan hastalar üzerinde üç farklı noktadan alınan ölçüm sonuçlarına göre, 128-kesit BT cihazında ölçülen yüzey dozlarının 16-kesit BT cihazında ölçülen yüzey dozlarından anlamlı derecede yüksek olduğu gözlenmiştir. Aynı zamanda tarama elde edilen ve radyasyon dozunun değerlendirilmesinde kullanılan doz ölçüm göstergelerinden CTDIvol, DLP, total DLP, kV, mAs, ışınlama süresi, kesit kalınlığı, pitch ve kesit sayısı gibi çekim parametreleri ve yaş, kilo, boy değişkenleride çalışmaya eklenmiştir. CTDIvol, DLP, total DLP, kesit sayısı, yaş, kilo ve boy değişkenlerinin dağılımı her iki cihazda benzer olarak bulunmuştur. Ancak kV, mAs, ışınlama süresi, kesit kalınlığı ve pitch değerleri farklılık göstermektedir. CTDIvol, DLP ve total DLP değerlerinin 16-kesit BT cihazında daha yüksek olmasına karşın ölçülen yüzey dozlarının 128-kesit BT cihazında daha yüksek olduğu gözlenmiştir.

Özet (Çeviri)

In this study, thyroid gland, right eye and left eye surface dose measurements were taken, in two different computed tomography devices, 50 patients in each device, in total 100 patients. TLD-100 dosimeters were used for dosimetric measurements. According to the measurement results obtained from three different points on the patients who underwent thorax tomography scanning, the measured surface doses in the 128-section CT device were found to be significantly higher than the surface doses measured in the 16-section CT device. At the same time, the measurement parameters such as CTDIvol, DLP, total DLP, kV, mAs, scan time, slice thickness, pitch and number of slices, which are obtained during scanning and used in the evaluation of radiation dose, were added to the study. The distribution of CTDIvol, DLP, total DLP, number of slices, age, weight and height variables was similar in both devices. However, kV, mAs, scan time, slice thickness and pitch values differ. CTDIvol, DLP and total DLP values were higher in the 16-section CT device, but the measured surface doses were higher in the 128-section CT device.

Benzer Tezler

  1. Acil servise nefes darliği ile başvuran hastalarda ilk tani araci olarak blue protokol akciğer ultrasonografisi ile toraks BT karşilaştirilmasi

    Comparison of blue protocol lung ultrasonography and thoracic ct as the first diagnostic tool in patients presenting to the emergency department with dyspnea

    HUDA ALMADHOUN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2021

    İlk ve Acil YardımSağlık Bilimleri Üniversitesi

    Acil Tıp Ana Bilim Dalı

    DOÇ. DR. AVNİ UYGAR SEYHAN

  2. Pulmoner nodüllerin boyutuna göre tespit edilebilirliğinin multidedektör bilgisayarlı tomografi-manyetik rezonans görüntüleme sekanslarıyla karşılaştırılması ve değerlendirilmesi

    Comparison and evaluation of multidectector computerized tomography-magnetic resonance imaging detectability of pulmonary nodulesby size

    HÜSEYİN ALPER KIZILOĞLU

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2018

    Radyoloji ve Nükleer TıpAtatürk Üniversitesi

    Radyoloji Ana Bilim Dalı

    DOÇ. DR. ADEM KARAMAN

  3. Trakya bölgesinde kedi ve köpeklerde bilgisayarlı tomografi görüntülemesi ile tanı konulan toraks hastalıklarının değerlendirilmesi

    Evaluation of the findings obtained in cases of thorax tomography imaging in cats and dogs in the Thrace region

    OSMAN AYDIN KARA

    Yüksek Lisans

    Türkçe

    Türkçe

    2024

    Veteriner HekimliğiAfyon Kocatepe Üniversitesi

    Veterinerlik Cerrahisi Ana Bilim Dalı

    PROF. DR. ZÜLFÜKAR KADİR SARITAŞ

  4. Postmortem izole kalp bilgisayarlı tomografisinden kardiyak kalsiyum skorlaması ve otopsi bulgularının karşılaştırılması

    Comparison of cardiac calcium score and autopsy findings from postmortem isolated cardiac computed tomography

    AHMET YAHYA GÜNGÖR

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2023

    Adli TıpPamukkale Üniversitesi

    Adli Tıp Ana Bilim Dalı

    PROF. DR. KEMALETTİN ACAR

  5. Diffüz parankimal akciğer hastalıkları tanısında fiberoptik bronkoskopinin tanısal etkinliğinin değerlendirilmesi

    Diagnostic yield of fiberoptic bronchoscopy in diffuse parenchymal lung diseases

    ALPER GÜNDOĞAN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2014

    Göğüs HastalıklarıGATA

    Göğüs Hastalıkları Ana Bilim Dalı

    PROF. DR. HAYATİ BİLGİÇ