Toraks bilgisayarlı tomografi taraması yapılan hastalarda tiroid gland ve orbitaların maruz kaldığı yüzey dozlarının iki farklı cihazda dozimetrik yöntemlerle belirlenmesi ve karşılaştırılması

Determination and comparison of thyroid gland and orbital surface doses that exposed to radiation in patients undergoing thorax computed tomography in TWO different devices by dosimetric methods

  1. Tez No: 544062
  2. Yazar: SEMRA ARSLAN
  3. Danışmanlar: DR. ÖĞR. ÜYESİ HÜSEYİN ÇETİN
  4. Tez Türü: Yüksek Lisans
  5. Konular: Radyoloji ve Nükleer Tıp, Fizik ve Fizik Mühendisliği, Radiology and Nuclear Medicine, Physics and Physics Engineering
  6. Anahtar Kelimeler: Bilgisayarlı tomografi, CTDIvol, DLP, TLD-100 dozimetre, yüzey dozu, Doz-cevap ilişkisi-radyasyon, Göğüs, Orbita, Radyasyon dozajı, Radyometri, Termoluminesan dozimetri, Tiroid bezi, Tomografi-x ışınlı-bilgisayarlı, Computed tomography, CTDIvol, DLP, TLD-100 dosimetry, surface dose, Dose-response relationship-radiation, Thorax, Orbita, Radiation dosage, Radiometry, Thermoluminescent dosimetry, Thyroid gland, Tomography-x ray-computed
  7. Yıl: 2019
  8. Dil: Türkçe
  9. Üniversite: Ankara Yıldırım Beyazıt Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Radyoloji Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu çalışmada iki farklı bilgisayarlı tomografi cihazında, her bir cihazda 50 hasta olmak üzere toplamda 100 hastada tiroid gland, sağ göz ve sol göz yüzeyinden doz ölçümleri alınmıştır. Dozimetrik ölçümlerde TLD-100 dozimetreleri kullanılmıştır. Toraks tomografi taraması yapılan hastalar üzerinde üç farklı noktadan alınan ölçüm sonuçlarına göre, 128-kesit BT cihazında ölçülen yüzey dozlarının 16-kesit BT cihazında ölçülen yüzey dozlarından anlamlı derecede yüksek olduğu gözlenmiştir. Aynı zamanda tarama elde edilen ve radyasyon dozunun değerlendirilmesinde kullanılan doz ölçüm göstergelerinden CTDIvol, DLP, total DLP, kV, mAs, ışınlama süresi, kesit kalınlığı, pitch ve kesit sayısı gibi çekim parametreleri ve yaş, kilo, boy değişkenleride çalışmaya eklenmiştir. CTDIvol, DLP, total DLP, kesit sayısı, yaş, kilo ve boy değişkenlerinin dağılımı her iki cihazda benzer olarak bulunmuştur. Ancak kV, mAs, ışınlama süresi, kesit kalınlığı ve pitch değerleri farklılık göstermektedir. CTDIvol, DLP ve total DLP değerlerinin 16-kesit BT cihazında daha yüksek olmasına karşın ölçülen yüzey dozlarının 128-kesit BT cihazında daha yüksek olduğu gözlenmiştir.

Özet (Çeviri)

In this study, thyroid gland, right eye and left eye surface dose measurements were taken, in two different computed tomography devices, 50 patients in each device, in total 100 patients. TLD-100 dosimeters were used for dosimetric measurements. According to the measurement results obtained from three different points on the patients who underwent thorax tomography scanning, the measured surface doses in the 128-section CT device were found to be significantly higher than the surface doses measured in the 16-section CT device. At the same time, the measurement parameters such as CTDIvol, DLP, total DLP, kV, mAs, scan time, slice thickness, pitch and number of slices, which are obtained during scanning and used in the evaluation of radiation dose, were added to the study. The distribution of CTDIvol, DLP, total DLP, number of slices, age, weight and height variables was similar in both devices. However, kV, mAs, scan time, slice thickness and pitch values differ. CTDIvol, DLP and total DLP values were higher in the 16-section CT device, but the measured surface doses were higher in the 128-section CT device.

Benzer Tezler

  1. Toraks ölçümleri ve solunum fonksiyonlarının antrenmanlarla değişimi

    Başlık çevirisi yok

    ERDOĞAN LİMAN

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    Uludağ Üniversitesi

    Yükleniyor...

  2. Septum deviasyonlarının akciğer fonksiyon testleri ve kan gazları üzerine etkileri

    Başlık çevirisi yok

    MEHMET ARMAĞAN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1988

    Erciyes Üniversitesi

    Kulak Burun Boğaz Ana Bilim Dalı

    Yükleniyor...

  3. Toraks içi kitlelerin ayırıcı tanısında ultrasonografinin değeri

    Başlık çevirisi yok

    SELMA KOLAK

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1989

    İstanbul Üniversitesi

    Radyodiagnostik Ana Bilim Dalı

    Yükleniyor...

  4. 16-24 gebelik haftaları arasında ultrasonografi ile BPÇ,FB,THÇ ölçümlerine göre gebelik yaşı tayini

    Başlık çevirisi yok

    HACER TAŞKESER

    Yüksek Lisans

    Türkçe

    Türkçe

    1989

    İstanbul Üniversitesi

    Tıbbi Genetik Ana Bilim Dalı

    Yükleniyor...

  5. Ispanakta (spinacia oleracea L.) bitki sıklığının tohum verimine etkisi üzerinde bir araştırma

    Başlık çevirisi yok

    FUNDA GÜREL

    Yüksek Lisans

    Türkçe

    Türkçe

    1989

    Uludağ Üniversitesi

    Bahçe Bitkileri Ana Bilim Dalı

    Yükleniyor...