Geri Dön

Yaralanmış sindesmozun dinamik tespitinde ideal sütür-buton yönelimi 'Sonlu Eleman Analizi Çalışması'

Optimal suture-button orientation in dynamic fixation of injured syndesmosis ' Finite Element Analiysis Study'

  1. Tez No: 545815
  2. Yazar: KAZIM TAŞAR
  3. Danışmanlar: PROF. DR. HAKAN ÖZDEMİR
  4. Tez Türü: Tıpta Uzmanlık
  5. Konular: Ortopedi ve Travmatoloji, Orthopedics and Traumatology
  6. Anahtar Kelimeler: Distal tibiofibular ligamentler, sindesmotik yaralanma, sonlu eleman analizi, dinamik fiksasyon, sütür-buton yönelimi, distal tibiofibular ligaments, syndesmotic injury, finite element analysis, dynamic fixation, suture-button orientation
  7. Yıl: 2018
  8. Dil: Türkçe
  9. Üniversite: Akdeniz Üniversitesi
  10. Enstitü: Tıp Fakültesi
  11. Ana Bilim Dalı: Ortopedi ve Travmatoloji Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 137

Özet

Bu çalışmada, sütür-buton ile yapılan dinamik tespitte, özellikle sindesmotik eklemin sagital plandaki suprafizyolojik anterior-posterior translasyon ve aksiyel plandaki rotasyon hareketini kısıtlayarak fizyolojik ligamentöz iyileşmeyi mümkün kılacak, ideal sütür-buton yönelimini belirlemek amaçlanmıştır. Sonlu eleman analiz yöntemi ile sağlam ayak bileği modeli ve Sikka Evre 4 sindesmotik yaralanma modeli oluşturulmuş ardından da sindesmotik yaralanmanın tespiti için sayı ve yönelimleri farklılık gösteren geleneksel tespit tipi (Model 1), diverjans tespit tipi (Model 2), AİTFL ve PİTFL' anatomik aksını taklit eden tespit tipi (Model 3), damar, sinir ve tendon koruyucu tespit tipi (Model 4), damar, sinir ve eklem kıkırdağı koruyucu tespit tipi (Model 5) olmak üzere fiksasyon modelleri tasarlanmıştır. Stance fazın 4. evresi olan Heel off fazının simulasyonu için ayak bileği 10° dorsifleksiyonda tibia platosuna 3528 N kompresif kuvvet ile anterior yönelimli 533 N tanjansiyel kuvvet uygulanmış ve fibulanın anteroposterior, mediolateral planlardaki yer değiştirmesi, aksiyel plandaki rotasyon açıları, A-TFCS ve P-TFCS mesafeleri değerlendirilmiştir. Çalışma sonucunda geleneksel tespit tipinin sindesmotik yaralanmalarda yeterli dinamik stabilizasyon sağlamadığı, AİTFL ile PİTFL'nin yönelimlerine uygun yönelim ve açıda uygulanan çift sütür-buton ile gerçekleştirilen tespitin (Model 3) ise sindesmozun anatomik redüksiyonu ve fibulanın fizyolojik hareketini olanaklı kılmakla birlikte patolojik sindesmoz diastazını engelleyen fiksasyon yöntemi olduğu tespit edilmiştir. Ek olarak, fiksasyon sırasında nörovasküler yapıların ve eklem kıkırdağı hasarının önüne geçmek için tasarlanan Model 5'in, Model 3'e kıyasla koronal ve sagital plandaki suprafizyolojik deplasmanı kısıtlama açısından, sırasıyla, % 3 ve % 1'lik zaafiyeti ile patolojik eksternal rotasyonu önlemede 0,5343°'lik yetersizliği bulunmakla birlikte ideale yakın dinamik stabilizasyon sağladığı saptanmıştır. Çalışma sonuçları geleneksel sütür-buton uygulaması yerine multiplanar dinamik stabilite sağlayan ve komplikasyon oranını en aza indiren Model 5 fiksasyon yönteminin sindesmozun anatomik redüksiyonu ve fibulanın fizyolojik hareketini olanaklı kılmakla birlikte patolojik sindesmoz diastazını engelleyen fiksasyon yöntemi olduğunu ortaya koymaktadır.

Özet (Çeviri)

The aim of this study was to determine the ideal suture-button orientation, which would enable physiological ligamentous healing by limiting the rotational movement of the syndesmotic joint in axial plane and supraphysiological anterior- posterior translation in sagittal plane. A solid ankle model and a Sikka Stage 4 syndesmotic injury model were developed with finite element analysis. Fixation models which varies in number and orientation were designed to detect syndesmotic injury: traditional fixaiton type (Model 1), divergence fixation type (Model 2); imitation of AITFL and PITFL's anatomical axis fixation type (Model 3); vein, nerve, and tendon protective fixation type (Model 4); vein, nerve, and articular cartilage protective fixation type (Model 5). In order to simulate the Heel off phase, which is the 4th phase of the stance phase, 3528 N compressive force and 533 N tangential force with anterior orientation were applied to the tibial plateau at 10° dorsiflexion of the ankle. And displacement of fibula in anteroposterior & mediolateral planes, rotation angles in axial plane, A-TFCS and P-TFCS distances were evaluated. The results of the study indicated that the traditional fixation type did not provide sufficient dynamic stabilization in the syndesmotic injuries and the fixation method performed with double suture-button which was applied in the proper orientation and angle of PITFL and AITFL (Model 3) prevented the pathologic syndesmosis diastasis while enabling the anatomical reduction of syndesmosis and the physiological movement of the fibula. In addition, Model 5 which was designed to prevent neurovascular structures and articular cartilage damage during fixation, had 0,5343°deficiency in the prevention of pathological external rotation and had weakness in terms of restraining the supraphysiological displacement in the coronal and sagittal plane, %3 and %1 respectively, compared to Model 3. Also it was found that Model 5 provided almost ideal dynamic stabilization. In conclusion, instead of conventional suture-button application, model 5 fixation method, which provides multiplanar dynamic stability and minimizes the complication rate, is the fixation method that prevents the pathologic syndesmosis diastasis while enabling the anatomical reduction of syndesmosis and physiological movement of fibula.

Benzer Tezler

  1. Ayak bileği sindezmoz yaralanmalarında vida ve sutur buton tekniği sonuçlarının karşılaştırılması

    Comparison of screw and suture button technique results in ankle syndesmosis injuries

    YUSUF SAİT DURAK

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2022

    Ortopedi ve TravmatolojiAtatürk Üniversitesi

    Ortopedi ve Travmatoloji Ana Bilim Dalı

    PROF. DR. ÖMER SELİM YILDIRIM

    YRD. DOÇ. DR. MUHAMMED ÇAĞATAY ENGİN

  2. Ayak bileği kırıklarında sindezmoz tespit gerekliliğinin retrospektif olarak incelenmesi

    Retrospective research of the necessity of the syndesmotic fixation in ankle fractures

    BORA GÜMÜŞLÜ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2016

    Ortopedi ve TravmatolojiKocaeli Üniversitesi

    Ortopedi ve Travmatoloji Ana Bilim Dalı

    DOÇ. DR. BİLGEHAN TOSUN

  3. Ayak bileği sindesmoz yaralanmalarının transfiksasyon vidası ile cerrahi tedavisi sonrası distal tibiofibular eklem malredüksiyon prevalansı ve fonksiyonel sonuçlara etkisi

    The prevalence of distal tibiofibular joint malreduction and its effect on functional outcomes after surgical treatment of ankle syndesmosis injuries with A transfixation screw

    NOSIRZHON USMANOV

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2023

    Ortopedi ve TravmatolojiMuğla Sıtkı Koçman Üniversitesi

    Ortopedi ve Travmatoloji Ana Bilim Dalı

    DOÇ. DR. ULAŞ AKGÜN

  4. İzole ayak bileği bağ yaralanmalarında AOFAS skoru gereksiz MR çekilmesini önleyebilir mi?

    Can AOFAS score prevent unnecessary MRi in isolated ankle ligament injuries?

    VEYSEL KANDEMİR

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2021

    Ortopedi ve TravmatolojiDicle Üniversitesi

    Ortopedi ve Travmatoloji Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ MEHMET SAİT AKAR

  5. Tibiofibular sindesmoz yaralanmalarının biyomekanik analizi: Sonlu elemanlar çalışması

    Biomechanical analysis of tibiofibular syndesmosis injuries: A finite element study

    NUMAN MERCAN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2021

    BiyomühendislikSelçuk Üniversitesi

    Ortopedi ve Travmatoloji Ana Bilim Dalı

    DOÇ. DR. AHMET YILDIRIM