Özet

Bu çalışmada evaporatif ped kullanımının kuru soğutucu kapasitesi üzerindeki etkisi incelenmiştir. Türkiye'nin dört farklı derece gün iklim bölgesinden İstanbul, Ankara, Antalya ve Erzurum illeri seçilerek evaporatif pedsiz kuru soğutucudan ve evaporatif pedli kuru soğutucudan elde edilen kapasiteler hesaplanarak karşılaştırma yapılmıştır. Belirtilen iller için Meteoroloji Genel Müdürlüğü'nden alınan saatlik sıcaklık ve nem değerleri aylık ortalama değerlere çevrilerek teorik analiz yapılmıştır. Kuru soğutucunun farklı hava şartlarındaki kapasite hesabı yapılırken hava debisi, akışkan giriş sıcaklığı ve akışkan debisi sabit kabul edilmiştir. Yapılan çalışmalar sonucunda hemen hemen her ilde her ay evaporatif ped kullanılmasının kapasiteye olumlu etki sağladığı görülmüştür. Özellikle Türkiye'de soğutma sezonu olan, Haziran, Temmuz, Ağustos ve Eylül aylarında dört il için de evaporatif ped kullanılması kapasiteyi %20 ve üzerinde arttırmıştır. Antalya (1.bölge) için yıl boyunca evaporatif ped kullanıldığında kapasite evaporatif pedsiz kuru soğutucuya göre ortalama %20,4 artmaktadır . Bu değer İstanbul (2.Bölge) için %19,4, Ankara(3.Bölge) için %17,2 ve Erzurum (4.bölge) için %11,1'dir. Antalya ili (1.bölge) için evaporatif pedli kuru soğutucu kullanılması diğer illere göre daha etkili olduğu görülmüştür. Deneysel çalışmada tek fanlı bir kuru soğutucuda havanın girişinde yerleştirilen evaporatif pedin soğutma kapasitesine etkisi çalışılmıştır. Çalışmada havanın kuru termometre sıcaklığı ve bağıl nemi ile evaporatif pedden çıkan havanın kuru termometre sıcaklığı ve bağıl nemi ölçülmüştür. Yapılan deneysel çalışmalar sonucunda, evaporatif ped sayesinde kuru soğutucu soğutma kapasitesinin %69,72 arttığı, suyun çıkış sıcaklığının %9,08 azaldığı ölçülmüştür.

Özet (Çeviri)

In this study, the effect of evaporative pad usage on dry cooling capacity was investigated. Dry cooler capacities with and without evaporative ped were compared for the cities of Istanbul, Ankara, Antalya and Erzurum from 4 different climatic regions of Turkey. Hourly temperature and humidity values obtained from Turkish Meteorological General Directorate for specified proviences are calculated by converting them to the monthly average values.Fluid inlet temperature and flow rate are considered as constant while the calculation of the dry cooler capacities in different weather conditions. Using evaporative pad has a positive effect on capacity in almost every province every month. Especially in cooling season , in June, July, August and September, evaporative pads for four provinces increased the capacity by 20% or more. During the year using evaporative pad dry cooler for Antalya (1st region) increased the capacity by 20,4% on average . This value is 19.4% for İstanbul (2nd region), 17.2% for Ankara (3rd region) , and 11.1% for Erzurum (4th region). The use of evaporative pad dry cooler for Antalya province (1st region) was found to be more effective than other provinces. In the experimental study, the values of the air after passing through the evaporative pad were measured using a single fan dry cooler. In this study, the dry bulb temperature and relative humidity of the air exiting the evaporative pad were measured and normal air temperature and relative humidity were measured. As a result of the experiment, it was found that the product capacity increased by 69.72% and the outlet temperature of water decreased by 9.08% thanks to evaporative pad.

Benzer Tezler

  1. Türkiye'de üç farklı iklim bölgesinde seraların iklimlendirilmesinde kullanılan bazı teknik parameterlerin belirlenmesi

    Determination of some technical parameters used for air conditioning of greenhouses in three different climate zones in Turkey

    MAHAMED ABDALLA MAKAUY ABASS MAHAMED ABDALLA MAKAUY ABASS

    Doktora

    Türkçe

    Türkçe

    2022

    ZiraatÇukurova Üniversitesi

    Tarımsal Yapılar ve Sulama Ana Bilim Dalı

    PROF. DR. ABDULLAH NAFİ BAYTORUN

  2. Güneş enerjisi kaynaklı ejektörlü soğutma sisteminin performansının araştırılması

    Investigation of the performance of solar-powered ejector cooling system

    ŞAKİR YALÇIN

    Yüksek Lisans

    Türkçe

    Türkçe

    2005

    Makine MühendisliğiSelçuk Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    YRD. DOÇ. DR. KÜRŞAD ERSOY

  3. Gece soğutmasının bina ısıl performansına etkilerinin saatlik analiz programı ile incelenmesi

    Investigation of the effects of night cooling on building thermal performance with hourly analysis program

    İSMAİL ÇELİK

    Yüksek Lisans

    Türkçe

    Türkçe

    2019

    Enerjiİstanbul Teknik Üniversitesi

    Enerji Bilim ve Teknoloji Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ MURAT ÇAKAN

  4. Doğal puzolan esaslı hafif jeopolimer duvar malzemesi

    Natural pozzolan based lightweight geopolymer wall material

    KÜBRA EKİZ BARIŞ

    Doktora

    Türkçe

    Türkçe

    2022

    Mimarlıkİstanbul Teknik Üniversitesi

    Mimarlık Ana Bilim Dalı

    PROF. DR. LEYLA TANAÇAN

  5. Farklı iklim şartlarındaki jeotermal santrallerin soğutma sisteminin optimizasyonu

    Optimisation of geothermal power plant cooling systems at different climatic conditions

    TUĞRUL BAŞARAN

    Doktora

    Türkçe

    Türkçe

    2019

    EnerjiYıldız Teknik Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    DOÇ. DR. BURHANETTİN ÇETİN