Geri Dön

Rotasyonel tromboelastometri ile yapılan fıbtem ölçüm parametrelerinin laboratuvar fibrinojen düzeyi ile ilişkisi

Correlation between rotational thromboelastometry fibtem parameters with laboratory fibrinogen levels

  1. Tez No: 549352
  2. Yazar: ESRA MURAT
  3. Danışmanlar: PROF. DR. HÜSEYİN İLKSEN TOPRAK
  4. Tez Türü: Tıpta Uzmanlık
  5. Konular: Anestezi ve Reanimasyon, Anesthesiology and Reanimation
  6. Anahtar Kelimeler: ROTEM, FIBTEM, MCF, fibrinojen, donör hepatektomi, ROTEM, FIBTEM, MCF, fibrinogen, donor hepatectomy
  7. Yıl: 2019
  8. Dil: Türkçe
  9. Üniversite: İnönü Üniversitesi
  10. Enstitü: Tıp Fakültesi
  11. Ana Bilim Dalı: Anesteziyoloji ve Reanimasyon Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 49

Özet

Rotasyonel Tromboelastometri ile Yapılan FIBTEM Ölçüm Parametrelerinin Laboratuvar Fibrinojen Düzeyi ile İlişkisi Amaç: Rotasyonel Tromboelastometri (ROTEM), temel olarak pıhtının viskoelastik ve mekanik özelliklerini değerlendirerek hemostatik sistem hakkında genel bilgi veren bir analizdir. ROTEM'in koagülasyon sisteminin izleminde, kan ve kan ürünleri transfüzyon ihtiyacının belirlenmesinde kullanım sıklığı artmıştır. Çalışmamızın amacı ROTEM FIBTEM parametrelerinin laboratuvar fibrinojen düzeyiyle korele olup olmadığını incelemektir. Materyal ve Metot: Canlı vericili karaciğer nakli için hepatektomi yapılması planlanan 30 donör çalışmaya dahil edildi. Hastalardan intraoperatif herhangi bir aşamada eş zamanlı kan alındı ve alınan kandan laboratuvarda Clauss yöntemiyle fibrinojen konsantrasyonu ve ROTEM'de fibrinojene en yakın parametre olarak değerlendirilen MCFFIBTEM ölçümü yapıldı. Bulgular: Eş zamanlı bakılan kanlarda Clauss yöntemiyle ölçülen fibrinojen değerlerinde %76 oranında hipofibrinojenemi görülmesine rağmen, MCFFIBTEM % 96,6 oranında normal aralıkta ölçüldü. Çalışmamızda Clauss fibrinojen konsantrasyonu ile MCFFIBTEM arasında kuvvetli bir korelasyon saptanmadı. Sonuç: Değerlendirmemizde laboratuvar fibrinojen konsantrasyonuyla FIBTEM arasında zayıf derecede korelasyon bulunmuş olup, standart koagülasyon testleriyle karşılaştırma amaçlı daha çok sayıda hasta içeren çalışmalara ihtiyaç olduğu sonucuna varıldı.

Özet (Çeviri)

ABSTRACT Introduction: Rotational Thromboelastometry (ROTEM) is an analysis that gives general information about hemostatic system by evaluating visco-elastic and mechanical properties of clot. ROTEM has been used frequently to evaluation of coagulation system, and in the determination of the need of blood and blood products for transfusion. The aim of our study was to examine whether ROTEM FIBTEM parameters correlate with laboratory fibrinogen concentration with Clauss method. Materials and Methods: Thirty donors who were planned to undergo donor hepatectomy for live donor liver transplantation were included in the study. Intraoperative simultaneous blood samples were taken from the patients and was measured by the Clauss method of the fibrinogen concentration and MCFFIBTEM as the nearest parameter to the fibrinogen of ROTEM. Results: Although the presence of hypofibrinogenemia was seen in 76% of the fibrinogen levels measured by the Clauss method, MCFFIBTEM was measured at a normal range in the patients of 96.6%. In our study, high degree of correlation was not found between Clauss fibrinogen concentration and MCFFIBTEM. Conclusion: There was a weak correlation between laboratory Clauss fibrinogen concentration and FIBTEM in our study and larger patient studies were needed.

Benzer Tezler

  1. Yoğun bakım yatış ihtiyacı olan COVİD-19 hastalarının rutin antikoagülasyon tedavisi altında koagülasyon profillerinin rotasyonel tromboelastometri ile incelenmesi

    Investigation of coagulation profiles of COVİD-19 patients who require intensive care admission under routine anticoagulation therapy by rotational thromboelastometry

    MUHAMMET SAİT BİLGİÇ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2023

    Anestezi ve ReanimasyonAnkara Üniversitesi

    Anesteziyoloji ve Reanimasyon Ana Bilim Dalı

    PROF. DR. MUSTAFA NECMETTİN ÜNAL

  2. %20 mannitol ve %3 NaCl sıvılarının koagulasyon parametreleri üzerine etkisinin in vitro ortamda karşılaştırılması

    A comparison of the effects of 20% mannitol and 3% NaCl on coagulation parameters in vitro

    BİLGE ŞENCAN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2017

    Anestezi ve Reanimasyonİstanbul Üniversitesi

    Anesteziyoloji ve Reanimasyon Ana Bilim Dalı

    PROF. DR. İBRAHİM ÖZKAN AKINCI

  3. Pediatrik yaş grubu uzun kemik deformitelerinin düzeltme prosedürlerinde hareket sensörü kullanımı

    Use of motion sensors in correction procedures of long bone deformities in the pediatric age group

    ABDULLAH NAVRUZ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2024

    Ortopedi ve TravmatolojiAtatürk Üniversitesi

    Ortopedi ve Travmatoloji Ana Bilim Dalı

    DOÇ. DR. MUHAMMED ÇAĞATAY ENGİN

  4. Rotasyonel hareketli preparasyon sistemlerinin debris ve smear tabakası yönünden değerlendirilmesi

    Evaluation of efficacy on debris and smear layer prepared by the rotational preparation systems

    KÜRŞAT ER

    Doktora

    Türkçe

    Türkçe

    2004

    Diş HekimliğiCumhuriyet Üniversitesi

    Diş Hastalıkları ve Tedavisi Ana Bilim Dalı

    YRD. DOÇ. DR. KEREM ENGİN AKPINAR

  5. Rotasyonel orman ile biyomedikal örüntü sınıflandırma

    Biomedical pattern classification with rotation forest

    HASAN KOYUNCU

    Yüksek Lisans

    Türkçe

    Türkçe

    2013

    Elektrik ve Elektronik MühendisliğiSelçuk Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    YRD. DOÇ. DR. RAHİME CEYLAN