R 410a akışkanlı soğutma sistemlerinde flaş gaz by-pass uygulaması

R 410a fluided flash gas by-pass application in cooling systems

  1. Tez No: 553801
  2. Yazar: UĞUR AYDIN
  3. Danışmanlar: PROF. DR. ARİF EMRE ÖZGÜR
  4. Tez Türü: Yüksek Lisans
  5. Konular: Enerji, Energy
  6. Anahtar Kelimeler: R410A, tek kademeli buhar sıkıştırmalı çevrim, flaş gaz, by-pass hattı, sıvı ayrıcı(flaş gaz tankı), akümülatör, R410A, transposer with single-stage vapor-compression cycle, flash gas, by-pass line, liquid separator(flash gas tank), accumulator
  7. Yıl: 2019
  8. Dil: Türkçe
  9. Üniversite: Isparta Uygulamalı Bilimler Üniversitesi
  10. Enstitü: Lisansüstü Eğitim Enstitüsü
  11. Ana Bilim Dalı: Enerji Sistemleri Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 78

Özet

Klima cihazı üretici firmaları son yıllarda birbirleriyle rekabet edebilmek amacıyla her geçen gün teknolojik alanda yeni arayışlar içerisine girdiklerinden farklı donanımlara ve özelliklere sahip cihaz üretme yoluna gitmişlerdir. Bunun neticesinde; enerji tüketimi az olan ve yaşadığımız dünyamıza, ozon tabakasına en az zarar verebilecek cihazlar üretmişler ve halen üretme arayışına devam etmektedirler. Bu gelişmeler sonucunda eski üretilen klima cihazlarında R22 gazı kullanılmaktayken yeni üretilen klima cihazlarında R410A gazı kullanılmaya başlanmış ve ozon tabakasına zarar vermeyen ozonla dost diye tabir ettiğimiz yeni soğutucu akışkanlar kullanılmaya başlanmıştır. Ayrıca üretici firmaların sera etkisi olmayan alternatif soğutucu akışkan kullanma arayışları da devam etmektedir. Sıvı hattında akan sıvı soğutkanın basıncı hattın her hangi bir yerinde, buradaki sıcaklığı doyma sıcaklığı haline getirecek bir basınç değerine düştüğünde ani-buharlaşma ortaya çıkar. Bu olguya flaş-gaz adı verilir ve flaş-gaz oluşumu, sistem kapasitesi üzerinde olumsuz etkileri nedeniyle önlenmesi gereken bir olgudur. Yaptığımız tez çalışmasında R410A soğutucu akışkanıyla çalışan bir Soğutma sisteminde, genleşme elemanı sonrasına yerleştirilen Flaş gaz tankı(sıvı ayırıcısı) sayesinde soğutma sisteminde meydana gelebilecek olan flaş gaz etkisinin azaltılması ve by-pass yapılarak flaş gazın emme hattına verilmesi suretiyle ortaya çıkan sonuçlar incelenmiştir.

Özet (Çeviri)

In recent years air conditioner manufacturers have been looking for new searches for competing with other manifacturers in technological area. Like different hardwares and specifications dealing with air conditioners. As a result of this they have manifactured devices that give less harm to our earth, the ozone layer and also use less electric. And they stil continue searching new ways. As a result of these improvements new manufactured air conditioners are using R410A gas while old manufactured ones are using R22 gas. These new air conditioners are been using new coolant fluid. This fluid is eco-friendly. In addition these manufacturers continue searching alternative coolant liquid that has non-green effect. The sudden vapurizing appears if the pressure of flowing cooling liquid in the liquid line reaches suddenly the satiety temprature in the anywhere of the pipe. That is called the flash gas and the flash gas effect must be prevented because of the unwillingly effects of the capasity of the system. In the end of this seminar studying we examined the cooling performance of the energy exergy in detail. An air conditioner runs with R410A cooling liquid and we reduced the effect of the flash gas expanding with by-pass and then the flash gas will be given to the observing line.

Benzer Tezler

  1. R-1234yf soğutkanlı asansör iklimlendirme ünitesi tasarımı

    R-1234yf soğutkanli asansör iklimlendirme ünitesi tasarimi

    MUSTAFA ARAZ

    Yüksek Lisans

    Türkçe

    Türkçe

    2013

    Makine MühendisliğiEge Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    PROF. DR. ALİ GÜNGÖR

  2. Çok kademeli doyma çevrimlerinin ekserji analizi

    Exergy analysis of multi-stage saturation cycles

    YUSUF ZİYA AKMAN

    Yüksek Lisans

    Türkçe

    Türkçe

    2018

    Makine MühendisliğiSelçuk Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    PROF. DR. HALİL KÜRŞAD ERSOY

  3. Ejektörlü soğutma sistemlerinde R410A kullanımı

    Using refrigerant R410A in cooling systems with ejector

    İLKER GÖKAY

    Yüksek Lisans

    Türkçe

    Türkçe

    2012

    Makine MühendisliğiPamukkale Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    PROF. DR. RASİM KARABACAK

  4. Soğutucularda farklı kılcal boru ebatlarının akış karakteristiği üzerindeki etkilerinin incelenmesi

    Investigation of the effect of different capillary tube sizes on the flow characteristic of cooling systems

    SAVAŞ EKŞİOĞLU

    Yüksek Lisans

    Türkçe

    Türkçe

    2017

    EnerjiMarmara Üniversitesi

    Makine Eğitimi Ana Bilim Dalı

    PROF. DR. MUSTAFA ATMACA

  5. Soğutma sistemlerinde kondenser kapasite kaybının sistem performansı üzerine etkilerinin deneysel ve teorik incelenmesi

    Experimental and theoretical investigation of effect of condenser capacitiy loss on system performance in refrigeration systems

    ABDUL CAN İNAL

    Yüksek Lisans

    Türkçe

    Türkçe

    2018

    Makine MühendisliğiKarabük Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    PROF. DR. EMRAH DENİZ