Forekazıklı ankrajlı duvar sistemlerinin sonlu elemanlar yöntemi ile analizi

Finite element analysis of prestressed anchored pile wall

  1. Tez No: 562659
  2. Yazar: MUHAMMED YASİN KALÇA
  3. Danışmanlar: DR. ÖĞR. ÜYESİ AYŞE BENGÜ SÜNBÜL
  4. Tez Türü: Yüksek Lisans
  5. Konular: İnşaat Mühendisliği, Civil Engineering
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2019
  8. Dil: Türkçe
  9. Üniversite: Zonguldak Bülent Ecevit Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: İnşaat Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 102

Özet

İnşaat sektöründe geoteknik mühendisliğinin yadsınamaz bir önemi bulunmaktadır. Zemini denge halinde tutabilmek için çeşitli sistemler geliştirilmiştir. Bu çalışma Forekazıklı iksa duvarı ve Ankrajlı diyafram duvar uygulamalarından oluşan sistemin tasarımı, Plaxis programıyla analizinin yapılması ve 5 kademeden oluşan kot farkı 60 metre olan 16 katlı bloklardan ve bu blokların önüne yapılacak olan villalardan oluşan bir site inşaatının şantiye sahasında imalatlarının yapılarak karşılaşılan sorunların değerlendirilmesinden oluşmaktadır. İmalat sırasıyla yukarıdan aşağıya şu şekilde yapılmıştır; Öncelikle 20 metre yüksekliğinde aralıklı forekazıklı iksa duvarı yapısı parametrik çalışma neticesinde tasarlanarak şantiyede imalatı gerçekleştirilmiştir. Bu iksa yapısının önüne 16 katlı bir binanın temel ve bodrum katlarının imalatının yapılabilmesi için şevli bir kazı yapılmıştır. Bu 16 katlı binanın altına yerinde dökme betonarme forekazıktan oluşan zemin güçlendirme uygulaması proje gereksinimleri doğrultusunda tasarlanarak sahada imal edilmiştir. Tam bu sırada forekazıklı iksa duvarının arkasındaki okulu yapısının bahçesinde çatlaklar meydana gelmiştir. Bu çatlakların iksa yapısının önüne açılan şevli kazı sebebiyle olduğu düşünülerek 16 katlı binanın temel ve bodrum katlarının imalatının yapılıp açılan şevin dolgusuna başlanmıştır. 16 katlı binanın yapımı devam ederken binanın 4 metre önüne 7 metre yüksekliğinde derin kazı yapılarak buraya binadan yük gelmeyeceği binanın yükünü kazıkların taşıyacağı düşünülerek 7 metre yüksekliğinde konsol tipi betonarme istinat duvarı yapılmıştır. Betonarme konsol tipi istinat duvarının 3.5 metre önüne 4 katlı bir villa yapısı konuçlandırılmıştır. Villanın 2 metre önünde 6 metre yüksekliğinde ankrajlı perde imalatı yapılarak destekleme sistemi oluşturulmuştur. Ankrajlı perdenin önüne yapılacak 2 katlı bir villa yapısı ve bu villanın da önüne yapılacak 6.5 metre yüksekliğindeki duvarın imalatı için şevli bir kazı çalışması yapılmış daha sonra buraya 6.5 metre yüksekliğindeki betonarme istinat duvarı yapılıp şev arkası doldurulmuştur. Bu çalışma yapılacak konut kompleksi için hazırlanan geoteknik tasarımların Plaxisde kademeli olarak analiz edilmesini kapsamaktadır.

Özet (Çeviri)

In today's city planning, deep excavations are very important in terms of engineering. Various systems have been developed to keep the soil in balance. This study covers the numerical modeling of the system consisting of prestressed anchored pile wall, cantilever type reinforced concrete retaining wall, prestressed anchored diaphragm wall and pile foundation applications. The first construction at the site is a 20 meter high prestressed anchored pile wall. It was designed as a result of the parametric work performed in numerical model and constructed in the site. In front of this shoring structure, 6 meter excavation was carried to construct foundation and basement of 16 storey building. Pile foundation of 16 storey building has been designed according to project requirement. In the meantime, cracks occurred in the garden of the school building behind the prestressed anchor pile wall. Considering that cracks were due to the excavation in front of the shoring system, and basement floors of the 16 storey building were constructed and the fill of the slope was started. While the construction of the 16-storey building was going on, a 7-meter-high cantilever-type reinforced concrete retaining wall was constructed, with the excavation of the building where the load would not be burdened by a deep excavation of 7 meters in front of the building. Reinforced concrete cantilever type retaining wall of 3.5 meters in front of the 6 meter high anchored wall was built. Then, a deep excavation work was carried out and a 6.5 meter high reinforced concrete retaining wall was built and the back of the slope was filled. The geotechnical designs prepared for the residential complex in this study will be produced as a gradual excavation in the Plaxis V9 dynamic module to prevent any insecure situation. İnteraction of structures and the construction defects are presented in the scope of this study.

Benzer Tezler

  1. Fore kazıklı-ankrajlı iksa sistemlerinin killi zeminlerde uygulanması

    Bored piling and anchored support system applied into clay soils

    ERTAN BOL

    Yüksek Lisans

    Türkçe

    Türkçe

    1996

    Jeoloji MühendisliğiÇukurova Üniversitesi

    DOÇ.DR. ATİKE NAZİK

  2. Derin kazılar ve derin kazı uygulamasına bir örnek: Hilton Garden Inn Sütlüce derin temel kazısı

    Deep excavations and a case study of deep excavations : Deep excavations of Hilton Garden Inn Sütlüce

    HABİP KOÇAK KÖSE

    Yüksek Lisans

    Türkçe

    Türkçe

    2011

    İnşaat Mühendisliğiİstanbul Teknik Üniversitesi

    İnşaat Mühendisliği Ana Bilim Dalı

    PROF. DR. AHMET SAĞLAMER

  3. Fore kazıklı iksalarda sonlu elemanlar yöntemi ile hesaplanan deplasmanların yerinde inklinometre ölçüm sonuçları ile karşılaştırılması

    Comparison of design deformations calculated with finite element method and inclinometer measurements in excavation support system with bored pile

    MUHAMMET YELER

    Yüksek Lisans

    Türkçe

    Türkçe

    2019

    İnşaat MühendisliğiYıldız Teknik Üniversitesi

    İnşaat Mühendisliği Ana Bilim Dalı

    PROF. DR. SUAT AKBULUT

  4. Derin kazılı iksa sisteminin sonlu elemanlar yöntemi ile analizi: İstanbul - Basf Teknopark örneği

    Analysis of the deep excaved shoring system by finite element method: Example of İstanbul - Basf Teknopark

    MERVE ÇOPAN

    Yüksek Lisans

    Türkçe

    Türkçe

    2020

    İnşaat MühendisliğiKaradeniz Teknik Üniversitesi

    İnşaat Mühendisliği Ana Bilim Dalı

    DOÇ. DR. SABRİYE BANU İKİZLER

  5. Ankrajlı fore kazıklı iksa sistemlerinin tasarımı ve sonlu elemanlar yöntemi ile analizi

    Design of anchored bored piled shoring systems and analysis with finite element method

    AHMET UĞUR CANOĞULLARI

    Yüksek Lisans

    Türkçe

    Türkçe

    2019

    İnşaat MühendisliğiToros Üniversitesi

    İnşaat Mühendisliği Ana Bilim Dalı

    PROF. DR. AZİZ ERTUNÇ