Özet

Bu çalışmanın amacı, HCFC-22 (Hidrokloroflorokarbon) soğutucu akışkanıyla çalışan bir klima cihazının, ozon dostu HFC-417A ve HFC-422D soğutucu akışkanlarıyla yapılan ölçümlerle, soğutma kapasitesi ve performans katsayısı (COP) gibi enerji parametrelerinin deneysel olarak araştırılmasıdır. Literatürde HCFC-22 yerine kullanılabilecek alternatif soğutucu akışkanlarla ilgili çalışmalar mevcut olmakla birlikte, özellikle küçük soğutma kapasiteli klimalarla ve çeşitli soğutucularla yapılmış çalışmaya rastlanmamıştır. Sistemde, iç ünitenin takılı olduğu yalıtımlı oda ve kondenserin çalıştığı dış ortamın sabit sıcaklıkta tutulması için yalıtımlı bir kanal kullanılmıştır. Deneyler için kapasitesi 2.05 kW olan konut tipi klima kullanılmıştır. Sıcaklık ve basınç değerlerini ölçmek için, ısıl çift ile basınç transdüseri yoğuşturucunun giriş kısmına ve çıkış kısmına, kompresörün giriş kısmına, genleşme valfinin giriş kısmına ve buharlaştırıcının çıkış kısmına yerleştirilmiştir. Bir debimetre ile kütlesel debi ölçülmüştür. Ölçümler, her soğutucu akışkan için tekrarlanmıştır. Ayrıca dış ortam ile yalıtımlı odanın sıcaklıkları da ölçülmüştür. Kompresör elektrik tüketimini ölçmek amacıyla güç ölçer kullanılmıştır. Ölçümlerin doğruluğunu tespit etmek için hata analizi yapılmıştır. Ölçümlerle soğutma kapasitesi, enerji tüketimi ve COP değerleri hesaplanmıştır. Deneysel sonuçlar detaylı bir şekilde analiz edilip değerlendirilmiş. Sistemin enerji parametreleri elde edilmiş ve her gaz için elde edilen ölçümler kendi aralarında karşılaştırılmak üzere aynı grafik üzerinde sunulmuştur. Sistem enerji parametrelerinin gaz tiplerine göre nasıl değiştiği saptanmıştır. Grafiklerle belirtilen sonuçların geniş bir analizi ve yorumu yapılmıştır. Çalışmadan elde edilen bulguların, soğutma ve iklimlendirme alanındaki araştırma ve tasarımlar için faydalı bir kaynak olması beklenmektedir.

Özet (Çeviri)

The goal of this survey is to empirical research the energy factors like refrigerating capability and performance coefficient (COP), by measurements with ozone-friendly refrigerants HFC-417A and HFC-422D (Hydrochlorofluorocarbons). Although there are studies about alternative refrigerants that can be used instead of HCFC-22 in the literature, there are no studies especially with small cooling capacity air conditioners and various refrigerants. An insulated duct is used in the system to keep the insulated room where the indoor unit is installed and the outdoor environment where the condenser operates at a constant temperature. A residential air conditioner system with a capability of 2.05 kW was used for the experiments. To measure temperature and pressure values, the thermocouple and the pressure transducer are located at the inlet and outlet of the condenser, the inlet of the compressor, the inlet of the expansion valve, and the outlet of the evaporator. Mass flow ratio was evaluated with a flow meter. The measurements were repeated for each refrigerant. In addition, the temperatures of the outside and insulated rooms were measured. Compressor power meter was used to measure electricity consumption. Error analysis was performed to determine the accuracy of the measurements. Cooling capacity, energy consumption and COP values were calculated. Experimental results were analyzed and evaluated in detail. The energy parameters of the system are obtained and the measurements obtained for each gas are presented on the same graph for comparison between each other. It has been determined how system energy parameters change according to gas types. A wide analysis and interpretation of the results indicated in the graphs were made. The findings of the study are expected to be a useful resource for research and design in the field of refrigeration and air conditioning.

Benzer Tezler

  1. Mevcut soğutma gruplarının yeni soğutucu akışkanlara adaptasyonu

    The Present cooler groups will have to adapted with vew cooler fluids

    KEMAL ORTATEPE

    Yüksek Lisans

    Türkçe

    Türkçe

    1997

    Eğitim ve ÖğretimMarmara Üniversitesi

    Makine Eğitimi Ana Bilim Dalı

    PROF. DR. A. ALP SAYAR

  2. Ticari tip soğutma sistemlerinde kullanılan soğutucu akışkanların termal görüntü işleme tekniği ile performanslarının incelenmesi

    The investigation of the performances of the refrigerants used in commercial refrigeration systems with thermal image processing techniques

    ZAFER CİNGİZ

    Doktora

    Türkçe

    Türkçe

    2020

    Elektrik ve Elektronik MühendisliğiSakarya Uygulamalı Bilimler Üniversitesi

    Makine Eğitimi Ana Bilim Dalı

    PROF. DR. YUSUF ÇAY

    DR. ÖĞR. ÜYESİ FERZAN KATIRCIOĞLU

  3. Performance comparison on the vapour compression refrigeration system when retrofitting from R22 to R404A

    Soğutucu akışkan R22?den R404A?ya geçilen buhar sıkıştırmalı soğutma sistemlerinde sistem performansının karşılaştırması

    SEDA KAYA

    Yüksek Lisans

    İngilizce

    İngilizce

    2009

    Makine MühendisliğiMarmara Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    YRD. DOÇ. DR. EBRU MANÇUHAN

  4. Organik rankine çevriminde gaz karışımlarının deneysel olarak incelenmesi

    Experimental investigation of gas mixtures in organic rankine cycle

    MEHMET KALE

    Yüksek Lisans

    Türkçe

    Türkçe

    2017

    EnerjiKarabük Üniversitesi

    Enerji Sistemleri Mühendisliği Ana Bilim Dalı

    YRD. DOÇ. ALPER ERGÜN

  5. Jeotermal enerji destekli organik rankine çevriminde alternatif akışkan kullanımının deneysel incelenmesi

    Experimental investigation of the use of alternative fluid on organic rankine cycle with geothermal energy

    GÖKNUR KAYATAŞ

    Yüksek Lisans

    Türkçe

    Türkçe

    2016

    EnerjiKarabük Üniversitesi

    Enerji Sistemleri Mühendisliği Ana Bilim Dalı

    PROF. DR. MEHMET ÖZKAYMAK