Geri Dön

Otomobil iklimlendirme sistemleri için farklı alternatif soğutucu akışkanların performanslarının değerlendirilmesi

Evaluating performance of different alternative refrigerants for automotive air conditioning systems

  1. Tez No: 569710
  2. Yazar: EREN SOYLU
  3. Danışmanlar: DR. ÖĞR. ÜYESİ MEHMET DİREK
  4. Tez Türü: Yüksek Lisans
  5. Konular: Makine Mühendisliği, Mechanical Engineering
  6. Anahtar Kelimeler: Otomobil ısı pompası, iç ısı değiştirici, GWP, R152a, R1234yf, R1234ze(E), Automotive heat pump, internal heat exchanger, GWP, R152a, R1234yf, R1234ze(E)
  7. Yıl: 2019
  8. Dil: Türkçe
  9. Üniversite: Yalova Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Enerji Sistemleri Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Enerji Sistemleri Mühendisliği Bilim Dalı
  13. Sayfa Sayısı: 120

Özet

Küresel ısınmanın günümüzde etkisini şiddetle hissettirmesi, devletleri ve uluslararası kuruluşları küresel ısınmanın etkilerini sabitleyecek ve azaltacak çalışmalar ve düzenlemeler yapmak zorunda bırakmıştır. Bu düzenlemeleri en önemlilerinden biri de otomobil iklimlendirme sistemlerinde kullanılan ve yüksek küresel ısınma potansiyeline (GWP) sahip soğutucu akışkanların kullanımının sınırlandırılmasıdır. Bu hususta Avrupa Parlementosu GWP'si 150'nin üzerinde olan soğutucu akışkanların kullanımının sınırlandırması kararı almıştır. Halihazırda otomobil iklimlendirme sistemlerinde kullanılan en yaygın soğutucu akışkan R134a (GWP=1300)'dır. R134a akışkanı soğutma sistemleri için yüksek performans sağlamasına rağmen yüksek küresel ısınma potansiyeli ile çevreye büyük zarar veren ve Avrupa Parlementosu tarafından engellenecek akışkanlardan biridir. R134a soğutucu akışkanının diğer soğutucu akışkanlar içerisinde yerine geçebilecek düşük küresel ısınma potansiyeline sahip en iyi alternatifler R1234yf, R1234ze(E) ve R152a akışkanlarıdır. Bu akışkanlar Avrupa Parlementosu düzenlemelerine uygun olmalarına rağmen ya R134a kadar performans verememekte, yada sistem tasarımlarına uygunluk ve yanma sınıfları konusunda problem oluşturmaktadırlar. Bu eksikliklerin giderilmesi ve düşük küresel ısınma potansiyeline sahip soğutucu akışkanların performanslarında görülen olumsuzlukların giderilmesi amacıyla düşük küresek ısınma potansiyeline sahip soğutucu akışkan çalışmaları yapılmaktadır. Bu tez kapsamında düşük küresel ısınma potansiyeline sahip R152a, R1234yf ve R1234ze(E) soğutucu akışkanlarının performansları R134a ile karşılaştırılmıştır. Deneysel ısı pompası sisteminde farklı soğutcu akışkanlar hem ısıtma, hem de soğutma modunda test edilmiştir. Aynı zamanda sıvı hattına yerleştirilen plakalı bir iç ısı değiştiricinin, düşük performanslı soğutucu akışkanların sistem performans parametreleri üzerine etkisi incelenmiştir. R152a soğutucu akışkanının STK'sı R134a'dan %11 oranında fazla olduğundan sistem üzerinde ısı değiştiricisine ihtiyaç duymamaktadır. İç ısı değiştiricisinin sistemde aktif olmasıyla R1234yf ve R1234ze(E) soğutucu akışkanının STK'sında sırasıyla %5-6 ve %4-5 oranında artış meydana gelmiştir. Deneysel ısı pompası sistemi ısıtma modunda incelendiğinde R152a'nın Isıtma Tesşr Katsayısı (ITK) R134a'dan %2 oranında daha yüksek, R1234yf ve R1234ze(E) soğutucu akışkanlarının ITK değerleri incelendiğinde ise akışkanların ITK'ları R134a'dan sırasıyla %4 ve %11 oranında daha düşük gerçekleşmiştir.

Özet (Çeviri)

Governments and international organizations started to work and regulate for stop and reduce the effect of global warming due to the environmental impacts. One of the important regulation is limiting the usage of high global warming potential (GWP) refrigerants, which widely used in automotive air conditioning systems. European Parliament decided to restrict the use of high global warming refrigerants that have GWP more than 150 in this connection. R134a is extensively used refrigerant in automotive air conditioning systems currently. In spite of high performance in refrigeration systems, R134a has a high global warming potential refrigerant and it will banned by the European Parliament. The best lowGWP alternatives of R134a are R1234yf, R1234ze(E) and R152a. However, these refrigerants cannot fulfill the performance needs or cannot satisfy the flammability requirements of the industry despite meeting European Parliament regulations. There must be certain improvements in air conditioning system designs for using low-GWP refrigerants and obviate failure to fulfillment. A lot of methods for improving the coefficient of performance (COP) has been proposed. The most common method is integrating an internal heat exchanger to condenser exit that exchanges heat with compressor suction line. The performance of low-GWP refrigerants R152a, R1234yf and R1234ze(E) has compared within the scope of this thesis. An experimental heat pump (EHP) system was developed for comparing performance parameters. The EHP system gives opportunity of testing the performance of low-GWP refrigerants at heating and refrigeration modes. Effect of the brazed plate heat exchanger on low-GWP weak refrigerant's refrigeration performance was conducted meanwhile. Because COP of R152a is %11 more than R134a, it doesn't require performance improvements. After the activation of the internal heat exchanger, the COP of R1234yf and R1234ze(E) has increased %5-6 and %4-5, respectively. R152a has %2 more COP than R134a when the experimental heat pump system working at heating mode. The COP of R1234yf and R1234ze(E) has %11 and %4 lower than R134a, respectively.

Benzer Tezler

  1. TVS Pulman yolcu vagon klima sistemlerinde FV panel kullanımı ve enerji verimliliği

    FV panel use and energy efficiency in TVS Pulman passenger wagon air conditioning systems

    EROL ARSLAN

    Yüksek Lisans

    Türkçe

    Türkçe

    2019

    EnerjiKarabük Üniversitesi

    Enerji Sistemleri Mühendisliği Ana Bilim Dalı

    PROF. DR. MEHMET ÖZKAYMAK

  2. Elektrikli otomobillerde termal konfor odaklı otonom iklimlendirmesistemi tasarımının enerji verimliliğine etkisinin incelenmesi

    Investigation of the effect of thermal comfort-focused autonomous air conditioning system design on energy efficiency in electric vehicles

    UĞURCAN YARDIMCI

    Doktora

    Türkçe

    Türkçe

    2024

    EnerjiFırat Üniversitesi

    Enerji Sistemleri Mühendisliği Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ EMRE TURGUT

  3. Çevresel sürdürülebilirliğe yönelik karbon ayak izinin konumsal analizi: Mersin Üniversitesi Çiftlikköy Kampüsü

    Spatial analysis of carbon footprint for environmental sustainability: Mersin University Çiftlikköy Campus

    MÜNEVVER ÇAĞAN

    Yüksek Lisans

    Türkçe

    Türkçe

    2024

    Jeodezi ve FotogrametriMersin Üniversitesi

    Uzaktan Algılama ve Coğrafi Bilgi Sistemleri Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ FATMA BÜNYAN ÜNEL

  4. Çeşitli tiplerde kompresör ve genleşme elemanı kullanan bir otomobil iklimlendirme sisteminin karşılaştırmalı deneysel analizi

    A comparative experimental analysis of an automobile air conditioning system using various types of compressors and expansion devices

    ALPASLAN ALKAN

    Yüksek Lisans

    Türkçe

    Türkçe

    2007

    Makine MühendisliğiKocaeli Üniversitesi

    Makine Eğitimi Ana Bilim Dalı

    DOÇ. DR. MURAT HOŞÖZ

  5. R134a kullanılan otomobil klima sisteminde r1234yf'nin, sıvı hattına eklenen bir ısı değiştiricisi ile deneysel olarak incelenmesi

    Experimental investigation of r1234yf with liquid line heat exchanger in automobile air-conditioning system used r134a

    AHMET AKIN

    Yüksek Lisans

    Türkçe

    Türkçe

    2017

    EnerjiYalova Üniversitesi

    Enerji Sistemleri Mühendisliği Ana Bilim Dalı

    YRD. DOÇ. DR. MEHMET DİREK