Kesme dayanımı yetersiz CFRP ile güçlendirilmiş kolon – kiriş birleşimlerinin çarpma davranışının incelenmesi

Investigation of impact behaviour of shear deficient reinforced concrete beam to column connection strengthened with CFRP strip

  1. Tez No: 582365
  2. Yazar: TURĞUT KAYA
  3. Danışmanlar: DR. ÖĞR. ÜYESİ ÖZLEM ÇALIŞKAN
  4. Tez Türü: Yüksek Lisans
  5. Konular: İnşaat Mühendisliği, Civil Engineering
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2019
  8. Dil: Türkçe
  9. Üniversite: Bilecik Şeyh Edebali Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: İnşaat Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 105

Özet

Betonarme yapı elemanları kullanım süreleri boyunca, patlama, kaya düşmesi, erozyon, toprak kayması, karayolu veya denizyolu köprülerine taşıt çarpması gibi nedenlerden dolayı impulsif dinamik yüklere maruz kalabilir. Bu nedenle, betonarme yapıların taşıyıcı sistemini oluşturan çerçevelerin kolon-kiriş birleşim noktalarının çarpma davranışlarının araştırılması ve bu etkilerin tasarım aşamasında dikkate alınması önemli bir konudur. Yürütülen tez çalışması kapsamında CFRP şeritleri ile güçlendirilmiş betonarme kolon-kiriş birleşim noktasının çarpma davranışı deneysel olarak incelenmiştir. Bu amaçla, kesme dayanımı yetersiz olan sekiz adet 1/3 ölçekli betonarme kolon-kiriş birleşim elemanı üretilmiştir. Betonarme kolon-kiriş birleşim elemanı monolitik olarak dökülmüş ve 200x200x1200 mm boyutlarında kolon ile kolon merkezine yerleştirilmiş 100x150x1500 mm boyutlarında kirişten oluşmaktadır. Deney elemanlarının üretiminde, 28 günlük basınç dayanımı 25 MPa olan beton ile 6 ve 8 mm çaplarında çelik donatılar kullanılmıştır. Güçlendirme işleminden önce, test numunelerinin alt ve yan yüzeyleri 50 mm genişliğinde ve 150-250 mm aralıklarla pürüzlendirilmiştir. Hazırlanan bu yüzeylere, 400 mm uzunluğunda ve 50 mm genişliğinde CFRP şeritler Sikadur 330 kullanılarak yapıştırılmıştır. Çarpma yükü deney elemanlarına ağırlık düşürücü test düzeneği kullanılarak uygulanmıştır. 84 kg kütleli çelik çekiç, 500 ve 750 mm'lik iki farklı yükseklikten düşürülerek, deney elemanlarına iki farklı çarpma enerjisi uygulanmıştır. Deneylerde, çarpma yükleri, deney elemanlarından ölçülen ivmeler, deplasmanlar, CFRP şeritlerin birim şekil değiştirmeler zaman-tanım alanında değişimler kaydedilmiştir. Deneysel değişkenlerin kaydedilen bu dinamik tepkiler üzerindeki etkileri incelenmiş ve CFRP şeritleri ile güçlendirilmiş betonarme kolon-kiriş birleşim elemanlarının çarpma davranışı elde edilen sonuçlarla yorumlanmıştır.

Özet (Çeviri)

Reinforced concrete (RC) structural members may be subjected to the effect of impulsive dynamic loads due to reasons such as explosion, rockfall, erosion, landslide, vehicle crash to the bridges of highway or seaway, in their service period. Therefore, it is an important issue to investigate the impact behavior of the column-beam joints of the frames constructing the bearing system of the reinforced concrete structures and also to consider these effect in the design stage. In the scope of the thesis study carried out, the impact behavior of RC beam-column joint strengthened with CFRP strips has been experimentally investigated. For that purpose, the eight 1/3 scaled RC column-beam joint elements of which shear strength is insufficient has been manufactured. RC beam-column joints were cast as monolithic and composed of the column part with the dimensions of 200x200x1200 mm and beam part with the dimensions of 100x150x1500 mm that was located to the center of the column part. The concrete of which 28-day compressive strength is 25 MPa and the rebars with the diameters of 6 and 8 mm has been used for the manufacture of test specimens. Before the strengthening procedure, the bottom and side surfaces of test specimens were roughened with a width of 50 mm and the spacing of 150-250 mm. The CFRP strips with a length of 400 mm and the width of 50 mm have been wrapped using Sikadur 330 to these prepared surfaces. Impact load was applied to test specimens using the drop-weight test setup. Two different input impact energies were applied to test specimens by dropping steel hammer with a weight of 84 kg from two drop-heights of 500 and 750 mm. The time-histories of impact loads, accelerations and displacements measured from test specimens and strains of CFRP strips were recorded in the experiments. The effects of the experimental variables on these dynamic responses recorded have been examined and the impact behavior of RC column-beam joint strengthened with CFRP strips has been interpreted with of results obtained.

Benzer Tezler

  1. Yetersiz betonarme kolon-kiriş birleşim bölgesinin deneysel olarak güçlendirilmesi

    Experimental strengthening of the deficient reinforced concrete beam-column joint

    KABİL ÇETİN

    Doktora

    Türkçe

    Türkçe

    2023

    İnşaat MühendisliğiManisa Celal Bayar Üniversitesi

    İnşaat Mühendisliği Ana Bilim Dalı

    PROF. DR. ALİ DEMİR

  2. Seismic retrofitting of R/C frames with deficient lap splices

    Yetersiz bindirme boyu bulunan betonarme çerçevelerin depreme karşı güçlendirilmesi

    SERAP ALTIN KAYA

    Yüksek Lisans

    İngilizce

    İngilizce

    2009

    İnşaat MühendisliğiBoğaziçi Üniversitesi

    İnşaat Mühendisliği Ana Bilim Dalı

    YRD. DOÇ. DR. KUTAY ORAKÇAL

  3. Yüksek eksenel yük ve kesme oranlarına maruz standart altı kolonların hibrit ince mantolama yöntemi ile güçlendirilmesi

    Seismic strengthening with novel hybrid thin jacketing methods of sub-standard rc columns exposed to high axi̇al load and shear rati̇os

    FURKAN NARLITEPE

    Yüksek Lisans

    Türkçe

    Türkçe

    2021

    Deprem Mühendisliğiİstanbul Teknik Üniversitesi

    Afet Yönetimi Ana Bilim Dalı

    PROF. DR. ALPER İLKİ

  4. BA kısa kolonlarda çatlak oluşumunun tespiti ve beton sınıfına bağlı olarak CFRP ve dış kuşaklama güçlendirmelerinin performansa katkısının deneysel araştırılması

    Experimental investigation on the determination of crack formation and contribution of CFRP and externally collar strengthenings to performance at the RC short columns

    YAŞAR GÜRKAN SEHAR

    Yüksek Lisans

    Türkçe

    Türkçe

    2019

    İnşaat MühendisliğiErciyes Üniversitesi

    İnşaat Mühendisliği Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ TAMER DİRİKGİL

  5. Kolon sarılma bölgelerinin CFRP kompozitler ile güçlendirilmesi

    Retrofit of column confinement zones with CFRP composites

    AYNUR TEZCAN

    Yüksek Lisans

    Türkçe

    Türkçe

    2004

    İnşaat Mühendisliğiİstanbul Teknik Üniversitesi

    İnşaat Mühendisliği Ana Bilim Dalı

    Y.DOÇ.DR. ALPER İLKİ