UPGRADE AND CHARACTERIZATION OF THE TUBITAK-SAGE EXPANSION TUBE

TÜBİTAK-SAGE GENİŞLEME TÜPÜNÜN YÜKSELTİLMESİ VE KARAKTERİZASYONU

  1. Tez No: 595127
  2. Yazar: MEHMET AKSAY
  3. Danışmanlar: DR. ÖĞR. ÜYESİ MUSTAFA PERÇİN
  4. Tez Türü: Yüksek Lisans
  5. Konular: Havacılık ve Uzay Mühendisliği, Aeronautical Engineering
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2019
  8. Dil: İngilizce
  9. Üniversite: Orta Doğu Teknik Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Havacılık ve Uzay Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Havacılık ve Uzay Mühendisliği Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Genişleme tüpleri sıcaklık basınç ve Mach sayısının birbirinden bağımsız olarak ayarlanabildiği eşsiz deney düzenekleridir. Bu düzenekler açık rüzgar tünelleri ile karşılaştırıldığında hipersonik hızlarda daha ucuz operasyon maliyeti sunarlar ancak test süreleri daha düşüktür. 150 mm çapa sahip TÜBİTAK-SAGE Genişleme Tüpü (ŞAHİ-1) 2013 yılında üretilmiştir. ŞAHİ-1 3 ila 11 arası Mach sayılarında uçuş koşullarını simüle etmek üzere tasarlanmıştır. ŞAHİ-1'in güncellenmesi ve test Mach sayısı bakımından karakterizasyonu gerekmekteydi ve bu çalışmada bu güncelleme ve karakterizasyon süreci anlatılmaktadır. Diğer ölçüm yöntemlerinin erişilebilir olmaması sebebi ile Schlieren fotoğraflama tekniği, yarı-analitik yaklaşım ve de hesaplamalı akışkanlar dinamiği (HAD) metodları bu düzeneğin Mach sayısı bakımından karakterizasyonu için kullanılmıştır. Bunun için 2 farklı kama ile 6 farklı koşulda toplamda 8 test gerçekleştirilmiştir. İstenilen test koşulları için gerekli olan doldurma basınçlarının tahmini için bir analitik hesap yöntemi kullanılmıştır. Dinamik basınç sensörü temelli yarı-analitik yöntem kullanılarak bulunan test odası statik sıcaklığı yardımı ile Schlieren resimlerinden hesaplanılan test odası Mach sayıları asıl değerler olarak düşünüldüğünde, istenilen Mach sayısı ve de test koşulları arasındaki hatanın ortalaması %41 olarak bulunmuştur. Bu hatanın bir kısmı genişleme kısmındaki yetersiz vakumlamadan kaynaklanan safsızlığa bağlanmıştır ve bunun uygun deney koşulları için iyileştirilmesi gerekmektedir. HAD analizlerinin %10 hata payı içerisinde test odası Mach sayısı değerlerini hızlı bir şekilde tahmininde kullanılabilineceğine karar verilmiştir. Bunun ötesinde, daha iyi Mach sayısı ölçümü için bu koşullarda çalışmaya uygun pitot tüpü ve de sıcaklık sensörüne ihtiyaç olduğuna karar verilmiştir.

Özet (Çeviri)

Expansion tubes are unique impulse type experimental facilities in which the temperature, pressure and Mach number can be adjusted independently. These facilities offer operation at hypersonic speeds at a lower cost compared to blowdown wind tunnels, yet they have a very short testing time. The TUBITAK-SAGE Expansion Tube (ŞAHİ-1) which has 150 mm diameter was built in 2013. ŞAHİ-1 was designed to simulate Mach numbers from 3 to 11. There was a need for upgrade and Mach number characterization of ŞAHİ-1 and this study explains the upgrade and characterization process. Due to the unavailability of other techniques this tube was intended to be characterized by using Schlieren photography, semi-analytical approach and computational fluid dynamics (CFD) techniques. There are 8 tests conducted with 2 different wedges at 6 different run conditions. An analytical method was used to estimate the fill pressures for the given desired flow conditions in the test section. When the Mach number values calculated from the Schlieren images by using the dynamic pressure transducer-based semi-analytical approach predicted temperatures are considered as the actual values, the average relative error between the desired Mach number values (i.e. input to the analytical method) and the operating conditions is 41%. Some of this error is attributed to the impurity of the expansion gas due to the poor vacuuming of the expansion section, which should be improved for proper experimentation. It is concluded that the CFD simulations would give a fast prediction of test room Mach numbers within 10% relative error margin with respect to Schlieren measurements. Moreover, it is concluded that a pitot probe and a temperature sensor are required for more accurate measurement of the test Mach number.

Benzer Tezler

  1. Demiryolu yük taşımacılığında optimum katar yükü probleminin incelenmesi

    Determination of the optimum train load in railway freight transportation

    SADETTİN ÖZEN

    Doktora

    Türkçe

    Türkçe

    1984

    İstanbul Teknik Üniversitesi

    Yükleniyor...

  2. Zonguldak (Kokaksu) bölgesi boksitlerinden alümina üretim parametrelerinin saptanması ve ekonomik değerlendirilmesi

    The Determination of the parameters of alümina production from the bauxite of Zonguldak (Kokaksu region) and the economic evaluation

    F.GÜNEŞ KOZA

    Doktora

    Türkçe

    Türkçe

    1985

    İstanbul Teknik Üniversitesi

    Yükleniyor...

  3. Kendini kabul envanterinin lise öğrencilerine uyarlanması

    Başlık çevirisi yok

    TULU TEMUGE

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    Hacettepe Üniversitesi

    Yükleniyor...

  4. Kütahya Gümüşköy-Aktepe baritinin flotasyonla zenginleştirilmesi

    Başlık çevirisi yok

    BAHRİ ÖTEYAKA

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Anadolu Üniversitesi

    Yükleniyor...