Yoğunluk ayarlı radyoterapi planları ve kalite kontrollerinin karşılaştırılması

Comparision of intensity modulated radiation therapy plans and their quality assurance

  1. Tez No: 610666
  2. Yazar: HİKMETTİN DEMİR
  3. Danışmanlar: PROF. DR. NİHAL BÜYÜKÇİZMECİ
  4. Tez Türü: Doktora
  5. Konular: Fizik ve Fizik Mühendisliği, Physics and Physics Engineering
  6. Anahtar Kelimeler: VMAT, Kayan Pencere, Step and Shoot, Homojeniti indeks, Konformiti indeks, VMAT, Sliding Window, Step and Shoot, Homogeneity İndex, Conformity İndex
  7. Yıl: 2020
  8. Dil: Türkçe
  9. Üniversite: Selçuk Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Fizik Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 97

Özet

Günümüzde kanser tedavisi için radyasyon yaygın olarak kullanılmaktadır. Bu amaçla kliniklerde kullanılan lineer hızlandırıcı cihazları radyasyonun uygulaması açısından farklılıklar göstermekle birlikte uyguladıkları tedavi teknikleri de birbirlerine göre farklılıklar içerir. Bu çalışmada nazofarenks, prostat, glioblastomemultiforme ve pankreas gibi yerleşimleri farklı dört kanser bölgesi için seçilen 10 hastanın farklı lineer hızlandırıcılar ile bunlara bağlı tedavi planlama sistemleri ile farklı tekniklerle yapılan yoğunluk ayarlı radyoterapi planlarının sonuçları incelenmiştir. Planlar yapılırken hedef tanımlanan dozu alırken kritik organların tolerans değerlerinin altında ve daha az doz alınmasına çalışılarak yapıldı. Hedef doz (PTV) kapsaması nazofarenks, prostat ve pankreas için en iyi tomoterapi sonuçlarında çıkarken, glioblastomemultiforme için VMAT tekniğinde çıkmıştır. Kritik organlar açısından ise her teknik farklı organda farklı üstünlükler göstermiştir. Çıkan sonuçlar literatürle benzerlikler göstermektedir. Tedavide istenen dozlara ulaşmak için verilen cihazın monitor unit değerleri en yüksekten en düşüğe doğru tomoterapi, kayan pencere, step and shoot ve VMAT tekniklerinde çıkmıştır. Tanımlanan dozun uygulanması için en çok ışınlama yapan cihaz tomoterapi cihazıdır. Hasta tedavi süresi en kısa teknik tedavi uygularken yüksek doz hızlarına da çıkabilen içinde birçok modülasyon yapabilen VMAT tekniği ile elde edilirken her alan için şekillendikten sonra durup ışınlama yapan step and shoot tekniği en uzun tedavi süresi olarak karşımıza çıkmıştır. Nazofarenks ve glioblastomamultiforme bölgeleri için yapılan tedavi planlarında en iyi homojeniti (HI) ve konformiti indeks (CI) değerleri tomoterapi tekniği ile elde edilmiştir. Prostat bölgesi için en iyi homojeniti indeks kayan pencere tekniği ile en iyi konformiti indeks ise step and shoot tekniği ile elde edilmiştir. Pankreas için ise en iyi homojeniti indeks tomoterapi ile elde edilirken en iyi konformiti indeks step and shoot tekniğinde elde edilmiştir.

Özet (Çeviri)

Nowadays radiation is widely used for cancer treatment. The linear accelerator devices used in clinics for this purpose show differences in terms of the application of radiation, but the treatment techniques they apply also contain differences according to each other. In this study, the results of 10 patients selected for four different cancer sites such as nasopharynx, prostate, glioblastoma multiforme and pancreas were examined with different linear accelerators, treatment planning systems related to them and intensity modulated radiotherapy plans with different techniques. Plans were made by trying to get the dose below the tolerance values of the critical organs while the target was taking the defined dose. The target dose (PTV) coverage was found in the best tomotherapy results for the nasopharynx, prostate and pancreas, while VMAT technique for glioblastoma multiforme was found. In terms of critical organs, each technique has shown different advantages in different organs. The results show similarities with the literature. In order to achieve the desired doses in the treatment, the monitor unit values of the device given were obtained from the highest to the lowest in tomotherapy, sliding window, step and shoot and VMAT techniques. While the shortest treatment time is achieved with the VMAT technique, which can perform many modulations in high dose rates, the step and shoot technique, which stops and irradiates after forming for each area, has been found to be the longest treatment time. In the treatment plans for the nasopharynx and glioblastoma multiforme regions, the best homogeneity(HI) and conformity index (CI) values were obtained by tomotherapy technique. The best homogeneity index for the prostate region was obtained by sliding window technique and the best conformity index was obtained by step and shoot technique. For the pancreas, the best homogeneity index is obtained by tomotherapy, while the best conformity index is obtained by step and shoot technique.

Benzer Tezler

  1. Prostat kanserlerinde farklı yoğunluk ayarlı radyoterapi planları için gama analizlerinin karşılaştırılması

    Comparison of gama analysis for different identity modulated radiotherapy plans in prostate cancer

    GÖKÇEN İNAN

    Doktora

    Türkçe

    Türkçe

    2020

    Radyoloji ve Nükleer TıpSelçuk Üniversitesi

    Fizik Ana Bilim Dalı

    PROF. DR. RIZA OĞUL

  2. Farklı tedavi planlama algoritmaları kullanılarak yapılan yoğunluk ayarlı radyoterapi planlarının karşılaştırılması ve kalite kontrollerinin yapılması

    Comparing and quality assurance of intensity modulated radiotherapy plans which are calculated with different treatment planning algorithms

    YÜCEL AKDENİZ

    Yüksek Lisans

    Türkçe

    Türkçe

    2011

    Fizik ve Fizik MühendisliğiHacettepe Üniversitesi

    Radyasyon Onkolojisi Ana Bilim Dalı

    PROF. DR. FADIL AKYOL

  3. Prostat kanserlerinin tedavisinde YART (Yoğunluk ayarlı radyoterapi) ve 3D-CR (3 boyutlu konformal radyoterapi) planlarinin dozimetrik olarak karşılaştırılması

    Dosimetric comparison of IMRT (ıntensity modulated radiotherapy) and 3-DCRT (three-dimension conformal radiotherapy) plans in the treatment of prostate cancers

    ÇİĞDEM KOCABAŞ

    Yüksek Lisans

    Türkçe

    Türkçe

    2019

    OnkolojiÇukurova Üniversitesi

    Medikal Fizik Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ HASAN SUAT ARSLANTAŞ

  4. Baş boyun kanserli hastalarda tedavi planlamalarının üç boyutlu gama analizi

    Three dimensional gamma analysis of treatment plans for head and neck cancer patients

    BÜŞRA TAVLI

    Yüksek Lisans

    Türkçe

    Türkçe

    2018

    Fizik ve Fizik MühendisliğiAcıbadem Mehmet Ali Aydınlar Üniversitesi

    Radyoloji Onkolojisi Ana Bilim Dalı

    PROF. DR. MELTEM SERİN

  5. Yoğunluk ayarlı radyoterapi uygulamalarında hasta planlarının kalite kontrollerinde iki farklı dozimetrik sistemin araştırılması

    Investigation of the quality assurance of patient treatment plans via two different dosimetic systems at intensity modulated radiation therapy applications

    SEDA ŞAHİN

    Yüksek Lisans

    Türkçe

    Türkçe

    2016

    Fizik ve Fizik Mühendisliğiİstanbul Üniversitesi

    Temel Onkoloji Ana Bilim Dalı

    PROF. DR. HATİCE BİLGE BECERİR