Kan, ankaferd, ferrik sülfat ve celox kontaminasyonunun kompozit rezin- dentin bağlanma dayanıklılığına etkisi

Effect of blood, ankaferd, ferric sulphate and celox contamination on composite resine-dentin bond strength

  1. Tez No: 615662
  2. Yazar: EBRU DELİKAN
  3. Danışmanlar: YRD. DOÇ. DR. KENAN CANTEKİN
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2015
  8. Dil: Türkçe
  9. Üniversite: Erciyes Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Çocuk Diş Hekimliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 84

Özet

Bu çalışmanın amacı amputasyon tedavileri sırasında kullanılan farklı hemostatik ajanların kompozit rezin- dentin bağlanması üzerine etkilerini belirlemektir. Çalışmamızda 100' ü kompozit rezinlerin baskı bağlanma dayanıklılığını incelemek, 20' si mikrosızıntı değerlendirilmesi olmak üzere toplam 120 adet çürüksüz çekilmiş süt molar dişi kullanılmıştır. Dişlerin okluzal yüzeylerinde dentin yüzeyi elmas separe kullanılarak açığa çıkarılmış ve dişler kökleri içeride kalacak şekilde akrilik rezin bloklara gömülmüştür. Her grupta 20 diş olacak şekilde 5 farklı grup oluşturulmuştur: Grup I: kontrol, Grup II: kan, Grup III: Ankaferd Blood Stopper(ABS), Grup VI: Celox ile, Grup V: Ferrik Sülfat. Grup II' deki dişler kan ile, Grup III-V'deki dişler belirlenen hemostatik ajanlar ile kontamine edilip hava su spreyi ile yıkandıktan sonra, dentin yüzeyine aynı çap ve yükseklikte kompozit rezin uygulanıp polimerize edilmiştir. Bağlanma dayanımlarını (SBS) değerlendirmek için instron cihazı kullanılmıştır. Kopma türünü değerlendirmek için örnekler ×20 büyütmeli stereomikroskopta incelenmiş ve kırılan yüzeyler SEM analizi yapılarak değerlendirilmiştir. Mikrosızıntının değerlendirilmesi için farklı 20 dişe sınıf V kaviteler açılarak kaviteler kan, ABS (Ankaferd sağlık ürünleri AŞ, Istanbul, Turkiye), Celox(MedTrade Products Ltd, Cheshire, UK) ve ferrik sülfat ile kontamine edilip hava su spreyi ile yıkandıktan sonra kompozit ile restore edilmiştir. 24 saat % 0.5' lik bazik fuksinde bekletilen dişlerde stereomikroskop altında mikrosızıntı değerlendirilmesi yapılmıştır. Çalışmamızdan elde ettiğimiz verilerin istatistiksel değerlendirilmesinde ANOVA tek yönlü varyans analizi, Tukey Post- hoc karşılaştırma testi ve Mann-Whitney U testi kullanılmıştır. Yapılan istatistiksel analiz sonucunda bağlanma direnci bakımından hemostatik ajanlar ve kontrol grubu arasında istatistiksel açıdan önemli fark gözlenmemiştir (p>0.05). Kullanılan hemostatik ajanlar arasında Celox (11.45±3.31) ve ferrik sülfat (8.22±5.29) grupları arasında anlamlı farklılık görülmezken (p>0.05), Celox- ABS ve ferrik sülfat- ABS arasında istatistiksel olarak anlamlı farklılıklar gözlenmiştir (p

Özet (Çeviri)

ABSTRACT The aim of this study was to determine the effect of different hemostatic agents (used in during pulpotomy procedures) to the composite resin- dentin shear bond strength and to make a comparison between the hemostatic agents. In our study, a total of 120 caries free primary teeth was used; 100 were used in shear bond strength research and 20 were used in microleakage research. Dentin surfaces of the teeth were revealed using a diamond saw and then embedded in crylic resin blocks. 5 groups were formed as each group has 20 teeth. The first group was control group (Group I), Group II contaminated with fresh human blood , Group III contaminated with Ankaferd Blood Stopper (ABS), Group IV contaminated with Celox and Group V contaminated with Ferric Sulfate. The samples were washed by air water spray then composite resin was placed in the same diameter and height and was polimerized. Instron testing machine was used to evaluate the shear bond strength (SBS). Samples were examined to evaluate the failure types at × 20 magnification using a stereomicroscope. To determine microleakage, class V cavities were prepared to different 20 teeth. The cavities were contaminated with blood, ABS, ferric sulfate, Celox, then washed with an air water spray and then restorated with composite. The samples were held on in 0.5% basic fucsin for 24 hours and microleakage evaluation was done under stereomicroscope. One-way ANOVA, Tukey post-hoc and Mann-Whitney U tests were used in statistical analysis. Significant statistical difference between the hemostatic agents and the control group was not observed. (p>0.05) The hemostatic agents Celox (11.45±3.31) and ferric sulfate (8.22±5.29) did not differ significantly (p>0.05) but ABS (7.46±4.48) showed significantly difference from the Celox(11.45±3.31). (p

Benzer Tezler

  1. Ankaferd kan durdurucu' nun sıçanlarda oluşturulan periodontal defektlerin rejenerasyonuna etkisi

    The effect of ankaferd blood stopper on the regeneration of periodontal defects in rats

    ŞEVKİ GÜLER

    Doktora

    Türkçe

    Türkçe

    2016

    Diş HekimliğiOndokuz Mayıs Üniversitesi

    Periodontoloji Ana Bilim Dalı

    PROF. BURCU ÖZKAN ÇETİNKAYA

  2. Tavşan gözlerinde kapak, konjonktiva ve skleral kesi modelinde Ankaferd Kan Durdurucu'nun kanama süresi ve yara iyileşmesi üzerine etkisinin araştırılması

    Cover rabbit eyes, conjunctival and scleral incision bleeding time model and Ankaferd Blood Durdurucu'nun investigate the effect on wound healing

    ZEYNEL ARSLANYILMAZ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2010

    Göz HastalıklarıFatih Üniversitesi

    Göz Hastalıkları Ana Bilim Dalı

    PROF. DR. YÜKSEL TOTAN

  3. Terapötik düzeyde warfarin sodyum uygulanan sıçanlarda diş çekimi sonrası ankaferd blood stopper uygulamasının yara ve kemik doku iyileşmesi üzerine etkisinin histopatolojik ve histomorfometrik olarak tespiti

    Histopathological and histomorphometric detection of ankaferd blood stoppers effects following tooth extraction on soft and bone tissue healing in the rats receiving warfarin sodium at therapeutic level

    AYHAN TETİK

    Doktora

    Türkçe

    Türkçe

    2012

    Diş HekimliğiEge Üniversitesi

    Ağız, Diş, Çene Hastalıkları ve Cerrahisi Ana Bilim Dalı

    PROF. DR. SEVTAP GÜNBAY

  4. Ratlarda deneysel olarak oluşturulan tam kat cilt kesisinde ankaferd blood stopper ampul uygulamasının yara iyileşmesi üzerine histopatolojik ve mekanik etkilerinin incelenmesi

    Investigation of the histopathological and mechanical effects of ankaferd blood stopper on the wound healing in a full skin incision in rats ezperimentally

    SERTAÇ HANCIOĞLU

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2018

    Çocuk CerrahisiOndokuz Mayıs Üniversitesi

    Çocuk Cerrahisi Ana Bilim Dalı

    DOÇ. DR. ÜNAL BIÇAKCI

  5. Meme hipertrofisi veya jinekomastiye yönelik meme ameliyatları ve ortognatik cerrahide topikal ankaferd blood stopper® uygulaması

    Investigation of ankaferd blood stopper® effect in breast surgery towards breast hypertrophy or gynecomastia and in orthognathic surgery

    SELMAN HAKKI ALTUNTAŞ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2010

    HematolojiSüleyman Demirel Üniversitesi

    Plastik Rekonstrüktif ve Estetik Cerrahi Ana Bilim Dalı

    DOÇ. DR. MUSTAFA ASIM AYDIN