Süneklik düzeyi yüksek perdelerde plastik mafsal boyunun çeşitli parametreler açısından irdelenmesi

Investigation of plastic hinge length in ductile shear walls in terms of various parameters

  1. Tez No: 615756
  2. Yazar: HACER TÜLEN
  3. Danışmanlar: PROF. DR. MUSA HAKAN ARSLAN
  4. Tez Türü: Yüksek Lisans
  5. Konular: İnşaat Mühendisliği, Civil Engineering
  6. Anahtar Kelimeler: Deprem, Yer değiştirme, Plastik Mafsal, Sonlu Elemanlar, Betonarme Perde, Earthquake, Displacement, Plastic Hinge, Finite Elements, Reinforced Concrete Shear Wall
  7. Yıl: 2020
  8. Dil: Türkçe
  9. Üniversite: Konya Teknik Üniversitesi
  10. Enstitü: Lisansüstü Eğitim Enstitüsü
  11. Ana Bilim Dalı: İnşaat Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 102

Özet

Perdeler boyutları itibari ile önemli yatay rijitlikleri olan elemanlardır. Rijitliğin haricinde deprem sırasında perdelerin yükseklik / genişlik oranına bağlı olmak kaydıyla mümkün olduğunca sünek bir şekilde davranıp yapı içinde payına düşen deprem kuvvetini ve enerjisini plastik ötesi deformasyon yaparak sönümlemesi istenir. Bu nedenle perdenin deprem esnasında plastikleşecek olan kritik bölgesinde kesme hasarının oluşmaması ve yeterli sünekliğin sağlanması için özel tasarım yapılır. Böylece deprem sırasında perdede oluşacak olan plastik mafsallaşmanın bu kritik bölge içinde oluşması beklenir. Betonarme yapı elemanlarında plastik mafsal boyunun gerçek yapı davranışa uygun olarak belirlenebilmesi yapılacak olan hesabın ve kabullerin gerçek davranışla mümkün olduğunca uyum içinde olması açısından oldukça önemlidir. Deprem sırasında yapı davranışında oldukça baskın olan betonarme perde gibi düşey taşıyıcı elemanların plastikleşme mekanizması ve plastik mafsal boyu yapı performansının değerlendirilmesi açısından son derece önemlidir. Bu tez çalışmasında betonarme perdelerin mafsallaşma bölgeleri (mafsal yükseklikleri) perdelerin davranışına etkin çeşitli parametreler açısından analitik olarak belirlenmiştir. Çalışmada ele alınan konu plastik mafsal olduğu için modellenen perdelerin lineer olmayan davranışları incelenmiş ve bu kapsamda da ABAQUS programı kullanılmıştır. Çalışmada farklı kesme açıklıklarına ve farklı yatay sargı donatısı oranlarına sahip, farklı normal kuvvet seviyelerinde 72 adet konsol perde yatay itme analizine tabi tutulmuştur. Yapılan analizler sonucunda elde edilen yük-deplasman grafiklerinde maksimum yükün %15 azaldığı andaki sınır durum ve Türkiye Bina Deprem Yönetmeliği-2018 (TBDY-2018) ile Türk Deprem Yönetmeliği-2007(TDY-2007)'de izin verilen maksimum yer değiştirme sınırları gözönüne alınmıştır. Bu sınırlara göre perde kesitlerinde özellikle perde uçlarında bulunan boyuna donatılarda meydana gelen akma durumuna göre belirlenen“analitik plastik mafsal boyları”(Lpz) ve basınç bölgesinde betonda meydana gelen ezilme durumuna göre“görünen plastik mafsal boyları”(Lp) ayrı ayrı belirlenmiştir. Elde edilen bulgular ile literatürde perdelerin plastik mafsal boyunu belirlemek için verilen ampirik formüller arasındaki uygunluk değerlendirilmiştir. Çalışmada ayrıca perdelerin deplasman süneklik değerleride incelenmiştir. Çalışma sonucunda; Kesme açıklığı arttıkça genel olarak plastik mafsal boylarının arttığı görülmüştür. Analitik plastik mafsal boyu ve görünen plastik mafsal boyu değerleri arasında 0.15-0.50 aralığında bir ilişki var olduğu gözlemlenmiştir. Literatürdeki ampirik formüllerden en yüksek yakınlığın görünen plastik mafsal boyu için %78 ve analitik plastik mafsal boyu için %69 ile Kazaz'ın önerdiği denklemle olduğu belirlenmiştir. Perdelerin süneklik değerleri incelendiğinde ise TBDY-2018'in tasarım koşullarını doğrular nitelikte sonuçlar elde edilmiştir.

Özet (Çeviri)

Reinfored concrete (RC) shear walls are element with significant lateral stiffness by their dimensions. In addition to the stiffness, the RC shear wall must to behaviour as ductile as possible depending on the height/ width ratio during the earthquake and ıt is requested to absorb the eartquake force which must be receive by forming plastic deformation. Special design is made in the critical area of the shear wall which will occur of plastic damage during the earthquake. With this shear wall design, it is aimed to avoid shear damage and to provide sufficient ductility. The determination of the plastic hinge length in accordance with the actual structure behaviour of the RC structural elements is very important in terms of ensuring that the account and the acceptantes to be made are in harmony with the actual behaviour. The plasticization mechanism and plastic hinge length of the vertical bearing elements such as reinforced concrete shear walls, which are very dominant in the construction behavior during the earthquake, are extremely important for the evaluation of the building performance. In this thesis, the hinging regions (hinge lengths) of the reinforced concrete walls were analytically determined in terms of various parameters effective on the behavior of the walls. Since the subject discussed in this study is plastic hinge, the nonlinear behavior of the modeled shear walls is examined. Examinations were made using ABAQUS program. In this study, 72 cantilever shear walls with different parameters were analyzed. The plastic length at the base of the RC shear wall models was determined on the basis of analysis results that depend on several parameters, such as the length / height ratio, axial load level and the ratio of the web horizontal reinforcement. As a result of the analysis, load-displacement graphs were obtained. In these graphs, 3 boundary situations are taken into consideration. This boundary conditions; Limit state at the time the maximum load is reduced by %15 and Turkish Earthquake Code 2007 (TEC 2007) with Turkish Building Earthquake Code 2018 (TBEC- 2018) permissible maximum displacement limits. According to these limits, the analytical plastic hinge lengths (Lpz) determined according to the yield situation in the longitudinal reinforcement especially at the shear wall ends and the visible plastic hinge lengths (Lp) according to the crushing situation at concrete in the pressure zone were determined separately. The findings were compared with the empirical formulas given in the literature to determine the plastic hing length of the shear walls. Displacement ductility values of the shear walls were also investigated. In the results of working; It has been observed that as the length / height ratio increases, plastic hinge lengths. It is observed that there is a relationship between analytical plastic hinge length and visible plastic hinge length values in the range of 0.15-0.50. Among the empirical formulas in the literature, the highest affinity was found to be 78% for apparent plastic hinge length and 69% for analytical hinge length according to the equation proposed by Kazaz. When the ductility values of the shear walls were examined, the results confirming the design conditions of TBEC -2018 were obtained.

Benzer Tezler

  1. Modeling of reinforcing bar buckling in structural walls

    Perdelerde donatı burkulmasının modellenmesi

    SURA SABAH SALIH SALIH

    Yüksek Lisans

    İngilizce

    İngilizce

    2019

    İnşaat MühendisliğiBoğaziçi Üniversitesi

    İnşaat Mühendisliği Ana Bilim Dalı

    DOÇ. DR. KUTAY ORAKÇAL

  2. Nonlinear analysis and retrofit strategy selection of a historical reinforced concrete building according to Turkish Earthquake Code 2007

    Tarihi betonarme bir yapının Türk Deprem Yönetmeliği 2007 uyarınca doğrusal olmayan tahlili ve güçlendirme yönteminin seçimi

    İSMAİL EMRAH KILIÇ

    Yüksek Lisans

    İngilizce

    İngilizce

    2008

    İnşaat MühendisliğiBoğaziçi Üniversitesi

    İnşaat Mühendisliği Bölümü

    PROF. GÜLAY ALTAY

  3. Seismic performance evaluation of dual reinforced concrete systems design according to turkish seismic code 2007

    Süneklik düzeyi bakımından karma taşıyıcı betonarme sistemlerin 2007 deprem yönetmeliği'ne göre performans değerlendirmesi

    E. YEŞİM KARCI

    Yüksek Lisans

    İngilizce

    İngilizce

    2007

    Deprem MühendisliğiBoğaziçi Üniversitesi

    Deprem Mühendisliği Ana Bilim Dalı

    PROF. DR. NURAY AYDINOĞLU

  4. Betonarme binalarda sistem sünekliğinin belirlenmesi

    Determination of system ductility on reinforced concrete buildings

    İSA YÜKSEL

    Doktora

    Türkçe

    Türkçe

    2000

    İnşaat MühendisliğiYıldız Teknik Üniversitesi

    İnşaat Mühendisliği Ana Bilim Dalı

    PROF. ZEKERİYA POLAT

  5. Depremlerde meydana gelen tipik betonarme yapı hasarlarına 2018 türkiye bina deprem yönetmeliğine göre alınabilecek önlemler

    Precautions for typical reinforced concrete structural damages occurred in earthquakes based on 2018 turkish building earthquake code

    ERDAL YILMAZ

    Yüksek Lisans

    Türkçe

    Türkçe

    2019

    Deprem Mühendisliğiİstanbul Teknik Üniversitesi

    Deprem Mühendisliği Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ ZEYNEP DEĞER