Bulk fill kompozit rezinlerin farklı tabaka kalınlıklarında ve farklı ışık güçlerinde polimerize edilmesinin kompozitin dönüşüm derecesi, mikro sertliği ve sitotoksisitesine etkisi

Effect of polymerization of bulk fill composite resins in different layer thicknesses and light irradiance on the degree of conversion, micro hardness and cytotoxicity of the composite

  1. Tez No: 629468
  2. Yazar: SEVDE GÜL BATMAZ
  3. Danışmanlar: DR. ÖĞR. ÜYESİ AYŞE DÜNDAR
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Dental restorasyon, Kompozit malzemeler, Kompozit reçineler, Mikrosertlik, Sitotoksisite, Dental restoration, Composite materials, Composite resins, Microhardness, Cytotoxicity
  7. Yıl: 2020
  8. Dil: Türkçe
  9. Üniversite: Akdeniz Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Restoratif Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Amaç: Bu çalışmanın amacı bulk fill kompozit rezinlerin farklı kalınlıklarda ve farklı ışık gücü modlarında polimerize edilmesinin kompozitlerin dönüşüm derecesi, mikro sertlik ve sitotoksisiteleri üzerindeki etkilerini değerlendirmektedir. Gereç ve Yöntem: Bu çalışma deneysel bir araştırma olup, bu çalışmada Sonic Fill 2 (SF), Filtek Bulk Fill (FBF) isimli iki farklı bulk fill kompozit rezin kullanıldı. Her iki kompozitten 5 mm çapında 2, 4 ve 6 mm kalınlıkta hazırlanan örnekler 2 farklı güç modunda (1000mW/cm2-20 sn ve 3200 mW/cm2- 3sn) polimerize edilerek her grupta 5 numune olacak şekilde dönüşüm derecesi, mikro sertlik ve sitotoksisite analizleri için toplamda 180 adet örnek elde edildi. Dönüşüm derecesi, Fourier Transform Infrared Spektrometre ile, mikro sertlik ölçümü Vickers sertlik ölçüm cihazıyla örneklerin alt ve üst yüzeylerinden yapılmıştır. Sitotoksisite, WST-1 testiyle fibroblast hücreleri (L929) kullanılarak 1,7 ve 21. günlerde analiz edilmiştir. SPSS 22 paket programı ile elde edilen verilerin istatistiksel analizi yapılmıştır. Bulgular: Bulk fill kompozit rezinlerin tabaka kalınlığı arttıkça kompozitlerin alt yüzeylerinde dönüşüm dereceleri anlamlı derecede azalmıştır (p<0,05). Sadece FBF 4 mm ve 6 mm kalınlığındaki örnekler arasında istatistiksel olarak anlamlı fark bulunmamaktadır. Bulk fill kompozit rezinlerin alt üst yüzey mikro sertlik oranları incelendiğinde her iki kompozitin her iki polimerizasyon yöntemiyle polimerize edilen 2 mm kalınlığında hazırlanan örnekleri ve standart güç modunda polimerize edilen 4 mm kalınlığındaki örnekleri 0,80 kabul edilebilir eşik değeri geçmiştir. WST-1 testinin sonuçlarına göre; en yüksek hücre canlılığı 7. günde Sonic Fill 2 kompozit rezinin standart güç modunda polimerize edilen 2 mm kalınlıktaki örneğinde görülmüştür. WST-1 deneyinin sonuçlarına göre; bulk fill kompozitlerin tabaka kalınlığı arttıkça hücre canlılığı azalmıştır. Sonuç: Bulk fill kompozit rezinler uygulama kolaylığı ve zaman tasarrufu sağlasa da artan tabaka kalınlığına bağlı yetersiz fiziksel ve mekanik özelliklere sahip olabilir ve sitotoksik etkiler gösterebilir.

Özet (Çeviri)

Purpose: The aim of this study is to evaluate the effects of polymerization of bulk fill composite resins in different layer thicknesses and different light power modes on the degree of conversion, micro hardness and cytotoxicity of composites. Materials and Methods: This study is an experimental study and two different bulk fill composite resins named Sonic Fill (SF) and Filtek Bulk Fill (FBF) were used in this study. A total of 180 composite samples with 5 mm diameter, 2, 4 and 6 mm thicknesses and polimerized with 2 different power modes (1000mW/cm2-20 sn and 3200 mW/cm2- 3sn) were prepared for the degree of conversion, micro hardness and cytotoxicity analaysis. The degree of conversion was measured with Fourier Transform Infrared Spectrometry, micro hardness measurement with the Vickers hardness tester from the lower and upper surfaces of the samples. Cytotoxicity was measured on days 1,7 and 21 using fibroblast cells (L929) with the WST-1 test. Statistical analysis of the data obtained was made with SPSS 22 program. Results: As the layer thickness of bulk fill composite resins increased, the degree of transformation in the lower surfaces of the composites were decreased significantly(p<0,05). There were no statistically significant difference except FBF 4 mm and 6 mm thickness samples. When the upper and lower surface micro hardness ratios of Bulk fill composite resins were examined, samples of both composites prepared in 2 mm thickness polymerized by both polymerization methods and 4 mm thickness samples polymerized in standard power mode have exceeded the acceptable threshold value of 0.80. According to the results of the WST-1 test; on the 7th day, the highest cell viability was seen in the 2 mm thick sample of Sonic Fill 2 composite resin polymerized in standard power mode. According to the results of WST-1 experiment; as the layer thickness of bulk fill composites increased, cell viability decreased. Conclusions: Although bulk fill composite resins provide ease of application and time savings, they may have insufficient physical and mechanical properties due to increased layer thickness and may show cytotoxic effects.

Benzer Tezler

  1. Halojen ve led ile polimerize edilmiş bulk fill kompozit rezinlerin dönüşüm derecesi ve mikrosertlik değerlerinin karşılaştırmalı olarak incelenmesi

    Comparative analysis of conversion degrees and microhardness values of bulk fill composite resins polymerized with different light devices

    MERVE KÜTÜK

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2018

    Ondokuz Mayıs Üniversitesi

    Restoratif Diş Tedavisi Ana Bilim Dalı

    Yükleniyor...

  2. Farklı yöntemlerle hazırlanan üç farklı kompozit rezinin dentine bağlanma dayanımlarının in vitro değerlendirilmesi

    Evaluation of the shear bond strength of three different composite resins to dentin which using different methods:in vitro

    ALPEREN MURAT YALNIZ

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2020

    Ankara Üniversitesi

    Restoratif Diş Tedavisi Ana Bilim Dalı

    Yükleniyor...

  3. Süt dişlerinde farklı viskozitelere sahip bulk fill kompozit rezinlerin marjinal adaptasyonunun mikro bilgisayarlı tomografi ile değerlendirilmesi

    Evaluation of the marginal adaptation of bulk-fill composite resins with different viscosities i̇n primary teeth using microcomputed tomography

    ECEM KARAKAŞ

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2026

    Gazi Üniversitesi

    Çocuk Diş Hekimliği Ana Bilim Dalı

    Yükleniyor...

  4. Süt molar dişlerin mod kavitelerinde farklı tip kompozit rezinlerin stres dağılımlarının incelenmesi

    Investigation of stress distribution of different types of composite resinsin mod cavities of primary molar teeth

    SELİN ACAR

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2023

    Ordu Üniversitesi

    Pedodonti Ana Bilim Dalı

    Yükleniyor...

  5. Shear bond strenght of three bulk-fill composites and conventional composites restorative material to dentine : In-vitro

    Bulk fill kompozit rezinler ve geleneksel kompozit rezinlerin dentine bağlanma dayanimlarinin in vitro değerlendirilmesi

    AHMED NOUHA

    Yüksek Lisans

    İngilizce

    İngilizce

    2014

    Yeditepe Üniversitesi

    Restoratif Diş Tedavisi ve Endodonti Ana Bilim Dalı

    Yükleniyor...