Halojen ve led ile polimerize edilmiş bulk fill kompozit rezinlerin dönüşüm derecesi ve mikrosertlik değerlerinin karşılaştırmalı olarak incelenmesi

Comparative analysis of conversion degrees and microhardness values of bulk fill composite resins polymerized with different light devices

  1. Tez No: 549717
  2. Yazar: MERVE KÜTÜK
  3. Danışmanlar: PROF. DR. ERTAN ERTAŞ
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Halojenler, Işık yayan diyot, Kompozit reçineler, Mikrosertlik, Halogens, Light emitting diode, Composite resins, Microhardness
  7. Yıl: 2018
  8. Dil: Türkçe
  9. Üniversite: Ondokuz Mayıs Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Restoratif Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Amaç: Bu çalışmanın amacı; yeni nesil tek tabaka halinde uygulanabilen bulk fill kompozit rezinlerin QTH ve LED ışık cihazları ile polimerize edilerek dönüşüm değerlerinin ve mikrosertlik düzeylerinin karşılaştırılmasıdır. Materyal ve Metot: Çalışmamızda 6 farklı bulk fill kompozit rezin; SDR (Dentsply), Sonic Fill (Kerr), X-tra Fil (VOCO), Beautifil Bulk Restorative (Shofu), Beautifil Bulk Flowable (Shofu), Filtek Bulk Flowable (3M ESPE) ve kontrol grubu olarak 1 adet mikrohibrit tipte Filtek Z250 (3M ESPE) kullanılımştır. Kompozit rezinlerden 7 mm çapında 2 ve 4 mm kalınlığında disk şeklinde örnekler hazırlanarak, LED (Elipar S10, 3M ESPE) ve QTH (Hilux, Benlioğlu) ışık cihazları kullanılarak polimerize edilmiştir. Örneklerin 24 saat 37 °C'de bekletilmesinin ardından FTIR-ATR (Perkin Elmer Spectrum Two) ile dönüşüm yüzdeleri belirlenmiş ve ardından Knoop sertlik cihazı (Buehler MMT-3 Digital microhardness tester; Lake Bluff, IL, USA) ile sertlik ölçümleri yapılmıştır. Verilerin istatistiksel değerlendirmesinde çok yönlü Varyans Analizi ve Tukey çoklu karşılaştırma testi uygulanmıştır (p<0.05). Bulgular: Tüm kompozit grupları içerisinde en yüksek dönüşüm derecesini 2 mm'de LED ışık cihazı ile Filtek Z250 gösterirken, en düşük değeri 4 mm'de QTH ile Beautifil Bulk Flowable göstermiştir. 2 mm LED ile polimerize edilmiş X-tra Fil alt ve üst yüzey sertlik ortalamalarında en yüksek değeri gösterirken, 4 mm'de QTH ile polimerize edilmiş Filtek Bulk Flowable üst yüzey, Filtek Z250 ise alt yüzey sertlik ortalamalarında en düşük değeri göstermişlerdir. Sonuç: Çalışmada kullanılan kompozit rezinlerin dönüşüm dereceleri ve sertlikleri örneklerin kalınlığından ve ışık cihazlarından etkilenmiştir. Bulk Fil kompozit rezinlerin dönüşüm dereceleri ile sertlik değerleri arasında ilişki olmadığı gösterilmiştir. Bütün kalınlıklarda LED ile polimerize edilen örneklerin dönüşüm ve mikrosertlik değerleri QTH'tan yüksek çıkmıştır.

Özet (Çeviri)

Purpose: The purpose of this study is to compare the conversion values and microhardness levels of new generation bulk fill composite resins that can be applied in one layer by polymerizing them with QTH and LED light devices. Material and Method: 6 different bulk fill composite resins SDR (Dentsply), Sonic Fill (Kerr), X-tra Fil (VOCO), Beautifil Bulk Restorative (Shofu), Beautifil Bulk Flowable (Shofu), Filtek Bulk Flowable (3M ESPE) and 1 microhybrid type Filtek Z250 (3M ESPE) as the control group were used in our study. Samples with a diameter of 7 mm and thickness of 2 and 4 mm in the form of discs were prepared from the composite resins and they were polymerized by using LED (Elipar S10, 3M ESPE) and QTH (Hilux, Benlioğlu) light devices. After the samples were kept for 24 hours at 37 °C, their conversion degree were found with FTIR-ATR (Perkin Elmer Spectrum Two) and their hardness measurements were made with Knoop hardness device (Buehler MMT-3 Digital microhardness tester; Lake Bluff, IL, USA). In the statistical assessment of the data, Multi-Way analysis of variance and Tukey multi comparison test were applied (p<0.05). Results: Of all the composite groups, while Filtek Z250 showed the highest conversion degree with LED light device at 2 mm, Beautifil Bulk Flowable showed the lowest conversion degree with QTH at 4 mm. While X-tra Fil polymerized with 2 mm LED showed the highest degree in bottom and top surface hardness averages, Filtek Bulk Flowable polymerized with QTH at 4 mm showed the lowest degree in top surface hardness averages and Filtek Z250 polymerized with QTH at 4 mm showed the lowest degree in bottom surface hardness averages. Conclusion: Conversion degrees and hardness of composite resins used in the study were influenced by the thickness of the samples and by the light devices. No association was found between the conversion degrees and hardness values of bulk fill composite resins. In all thicknesses, conversion and microhardness values of samples polymerized with LED were found to be higher than those of QTH.

Benzer Tezler

  1. Polisaj sonrası ekstra polimerizasyon uygulamasının kompozit rezinlerde renk değişimine etkisinin araştırılması

    Effect of extra polymerization after polishing procedures on color stability of composite resins

    KÜBRA ALAN

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2016

    Ondokuz Mayıs Üniversitesi

    Restoratif Diş Tedavisi Ana Bilim Dalı

    Yükleniyor...

  2. Yapay yaşlandırma işleminin ve polimerizasyon derinliğinin farklı ışık kaynakları ile polimerize edilen bulk fill kompozitlerdeki artık monomer miktarına etkisi

    Effect of artificial aging process and depth of curing on the amount of residual monomer in bulk fill composites polymerized with different light sources

    ÖMER HATİPOĞLU

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2017

    Recep Tayyip Erdoğan Üniversitesi

    Restoratif Diş Tedavisi Ana Bilim Dalı

    Yükleniyor...

  3. Lityum iyon sonrası batarya sistemleri için katı elektrolitlerin geliştirilmesi

    Development of solid electrolytes for post-lithium-ion battery systems

    MUSTAFA ÇELİK

    Doktora

    Türkçe

    Türkçe

    2026

    Sakarya Üniversitesi

    Metalurji ve Malzeme Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  4. Halojen ve led ışık kaynakları ile polimerize edilerek, farklı bitirme / polisaj teknikleri uygulanan iki farklı restoratif materyalin; yüzey sertliği, yüzey pürüzlülüğü ve biaksiyal fleksural dayanımlarının in vitro incelenmesi

    Polymerized with halogen and led light sources,two different restorative materials applied for different finishing / polishing techniques; in vitro investigation of surface hardness, surface roughness and biaxial flexural strength

    RÜYA ALPAR

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2019

    Süleyman Demirel Üniversitesi

    Çocuk Diş Hekimliği Ana Bilim Dalı

    Yükleniyor...

  5. Değişik ışık kaynaklarıyla polimerize edilmiş dental kompozitlerin sitotoksisitesi

    Cytotoxicity of dental composites polymerized with different light curing units

    DUYGU AKKOR

    Doktora

    Türkçe

    Türkçe

    2012

    Ankara Üniversitesi

    Diş Hastalıkları ve Tedavisi Ana Bilim Dalı

    Yükleniyor...