Otomatik ve manuel kan basıncı ölçümü araçlarının güvenirliği ve etkileyen faktörlerin incelenmesi
Reliability of automatic and manual blood pressure measurement devices and investigation of effecting factors
- Tez No: 651579
- Danışmanlar: DOÇ. DR. FUNDA BÜYÜKYILMAZ
- Tez Türü: Yüksek Lisans
- Konular: Hemşirelik, Nursing
- Anahtar Kelimeler: Güvenilirlik, Hemşirelik bakımı, Kan basıncı, Kan basıncı monitörleri, Kan basıncı ölçülmesi, Kardiyovasküler hemşirelik, Reliability, Nursing care, Blood pressure, Blood pressure monitors, Blood pressure determination, Cardiovascular nursing
- Yıl: 2020
- Dil: Türkçe
- Üniversite: İstanbul Üniversitesi-Cerrahpaşa
- Enstitü: Lisansüstü Eğitim Enstitüsü
- Ana Bilim Dalı: Hemşirelik Esasları Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Bu araştırma; otomatik ve manuel kan basıncı ölçüm araçlarının güvenirliğini ve etkileyen faktörleri belirlemek amacıyla tanımlayıcı tasarım türünde planlandı. Bir eğitim-araştırma hastanesinin koroner ara yoğun bakım ünitesinde yatan 110 hastanın kan basınçları, otomatik ve manuel kan basıncı ölçüm cihazı ile ölçülerek, elde edilen değerler girişimsel ölçüm sonucu (arter monitorü) ile karşılaştırıldı. Verilerin analizinde uygun istatiksel yöntemler kullanıldı. Çalışma kapsamına alınan hastaların yaş ortalamalarının 67,77±11,66 yıl, BKI ortalamalarının 27,74±4,45 kg/m2, kol çevresi ortalamalarının 27,51±2,48 cm. olarak belirlendi. Hastaların yaş, cinsiyet ve BKI ortalamlarının kan basıncı değerlerini etkilediği belirlendi (p<0,05). Hastaların tüm yatış pozisyonlarında sistolik kan basıncı için; arteriyal ölçüm ile diğer ölçümler arasındaki uyumun“mükemmel”düzeyde olduğu belirlendi. Diastolik kan basıncı için ise; arteriyal ölçüm ile manuel cihaz arasında“orta”düzeyde, otomatik cihazlarla“zayıf”düzeyde uyum olduğu saptandı (p<0,001). Hastaların tüm yatış pozisyonlarında arter monitörü ile diğer araçlarla yapılan ölçümler arasındaki kan basıncı değerleri arasındaki farklılığının anlamlı olduğu görüldü (p<0,05). Sonuç olarak kan basıncı aletleri arasında sistolik kan basıncında uyum düzeyi yüksek iken; diastolik kan basıncında uyumun düştüğü görülmektedir.
Özet (Çeviri)
This descriptive study aimed to determine the reliability of automated and manual blood pressure measurement tools and the factors affecting their reliability. Blood pressures of 110 patients admitted to the intermediate coronary intensive care unit were measured using automated and manual sphygmomanometers. An arterial catheter compared the other findings. The data were analyzed by using relevant statistical methods. Of the patients included in the study; the mean age was 67.77±11.66 years, the mean BMI was 27.74±4.45 kg m2, and the mean mid-arm circumference was 27.51±2.48 cm. It was determined that the mean age, gender and BMI of the patients were effected the blood pressure values (p <0.05). The systolic blood pressure readings obtained by all modes of blood pressure measurements in all lying down positions of the patients were found out to be in“perfect”agreement with the blood pressure readings obtained via an arterial catheter for the systolic blood pressure measurement. There was a“moderate”level of agreement between the diastolic blood pressure measurements obtained via an arterial catheter and the readings obtained by a manual device. The level of agreement between the diastolic blood pressure measurements obtained via an arterial catheter and the readings obtained by an automated device was“poor”(p<0,001). It was observed that the differences between the blood pressure values obtained by using an arterial catheter and other blood pressure devices were significant in all lying positions of the patients (p<0.05). In conclusion; the level of agreement is high across systolic blood pressure measurements obtained via different blood pressure devices, however, it is observed that the level of agreement across diastolic blood pressure were lower.
Benzer Tezler
- Effects of gas shielding flow rate on weld quality of tig welding in Ti6Al4V alloy
Ti6Al4V alaşımı tig kaynağında uygulanan koruyucu gaz parametresinin kaynak kalitesi üzerindeki etkisi
BANU BERİŞ
Yüksek Lisans
İngilizce
2012
Mühendislik Bilimleriİstanbul Teknik ÜniversitesiMalzeme Bilimi ve Mühendisliği Ana Bilim Dalı
PROF. DR. HÜSEYİN ÇİMENOĞLU
- Bilgisayarlı görü ile derin öğrenme tabanlı temassız kan basıncı tahmini
Computer vision based deep learning driven contactless blood pressure estimaion
HASAN AYDOĞAN
Yüksek Lisans
Türkçe
2026
Bilgisayar Mühendisliği Bilimleri-Bilgisayar ve KontrolSüleyman Demirel ÜniversitesiBilgisayar Mühendisliği Ana Bilim Dalı
DR. ÖĞR. ÜYESİ GÜL FATMA TÜRKER AKKAŞ
- Spinal anestezi uygulanan hastalarda iki farklı sedasyon protokolünün kardiyak elektrofizyoloji üzerine etkilerinin değerlendirilmesi
Evaluation of the effects of two different sedation protocols on cardiac electrophysiology in patients undergoing spinal anesthesia
SELVİNAZ DURANTAŞ
Tıpta Uzmanlık
Türkçe
2023
Anestezi ve ReanimasyonAnkara Yıldırım Beyazıt ÜniversitesiAnesteziyoloji ve Reanimasyon Ana Bilim Dalı
DR. ÖĞR. ÜYESİ BURAK NALBANT
- Hipertansif hastalarda otomatik osilometrik cihaz ile manuel sfingomanometrenin karşılaştırılması
Comparison of automated oscillometric device and manual sphygmomanometer among hypertensive patients
BARIŞ SANDAL
Yüksek Lisans
Türkçe
2021
Biyoistatistikİstanbul Üniversitesi-CerrahpaşaBiyoistatistik Ana Bilim Dalı
PROF. DR. ABDULBARİ BENER
- Primer dismenoreli kadınlarda miyofasyal gevşetme tekniğinin uterin arter kan akışı ve ağrı üzerine akut etkisinin incelenmesi
An investigation of the acute effects of myofascial release technique on uterine artery blood flow and pain in women with primary dysmenorrhea
ZEYNEP BEYZA ALKAN YILMAZ
Doktora
Türkçe
2025
Fizyoterapi ve RehabilitasyonGazi ÜniversitesiFizyoterapi ve Rehabilitasyon Ana Bilim Dalı
PROF. DR. SELDA BAŞAR