Geri Dön

Kompozit rezinlerin yüzey sertliğine farklı polimerizasyon sürelerinin ve asidik döngünün etkisi

Effect of different polymerization time and acidic cycle on surface hardness of composite resins

  1. Tez No: 656598
  2. Yazar: TUĞÇE YILMAZ
  3. Danışmanlar: DR. ÖĞR. ÜYESİ EBRU USLU CENDER
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2021
  8. Dil: Türkçe
  9. Üniversite: Ordu Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Diş Hastalıkları ve Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 112

Özet

Amaç: Bu çalışmanın amacı kompozit rezinlerin yüzey sertliğine farklı polimerizasyon sürelerinin ve asidik döngünün etkisini karşılaştırmalı olarak incelemektir. Gereç ve Yöntem: Araştırmada 4 farklı kompozit rezin; Filtek Ultimate universal akışkan (3M ESPE, USA), G-aenial universal akışkan (GC, JAPONYA), Gradia Direct Anterior (GC, JAPONYA) ve Filtek Z250 (3M ESPE, USA) kullanılarak 8 mm çapında ve 2 mm kalınlığında toplam 208 adet örnek hazırlandı. Her grup iki farklı içecekte bekletilmek üzere ikiye ayrıldı. Bu gruplar da kendi içlerinde farklı ışık modlarıyla polimerize edilmek üzere ikiye ayrıldı. Örnekler Valo Cordless LED (Ultradent, ABD) ışık cihazıyla üretici firmanın talimatları doğrultusunda iki farklı ışık modunda (standart mod, ekstra güç ışık modu) polimerize edildi. Polimerize edilen örnekler 24 saat, 37 ̊C etüvde bekletildi ve ardından tesviye ve polisaj işlemi gerçekleştirildi. Hazırlanan örneklerin ilk mikrosertlik ölçümleri (Vickers, Duramin, Struers, ABD) yapıldı. Örnekler 28 gün farklı asidik karaktere ve pH'ya sahip içeceklerde (kola, distile su) bekletildikten sonra mikrosertlik ölçümleri tekrarlandı. Bulgular: Vicker's sertlik testi uygulanan kompozitlerin sertlik oranlarının ortalama değerleri arasında istatistiksel olarak anlamlı farklılık görüldü (p˂0.05). Farklı sıvılarda bekletilmeleri sonucu yüzey sertliği en çok etkilenen Gradia Direct Anterior kompozit rezin olup, bu grubun ekstra güç ışık moduyla polimerize edildikten sonra kolada bekletilen numunelerinde tespit edilmiştir. (p=0,001). Solüsyonlardan bağımsız olarak; tüm ışık modlarında Filtek Z250 grubu en yüksek yüzey sertlik değerlerini gösterirken, Gradia Direct Anterior grubu en düşük sertlik ortalamasına sahiptir. Kompozitlerden bağımsız olarak solüsyonlar arasında kola, distile su gruplarına göre yüzey sertliğinde daha fazla azalmaya sebep olmuştur. Valo ışık cihazının ekstra güç modu uygulanan örneklerde ise en düşük sertlik değerleri bulunmuştur. Sonuçlar: Kompozit rezinler kompozisyonlarına bağlı olarak sıvılardan farklı oranlarda etkilenmiştir. Asidik içeceklerin rezin bazlı restoratif materyallerin yüzey sertliği değerlerinde değişimlere neden olduğu kaydedilmiştir. Valo ışık cihazının ekstra güç modu, standart moda göre yüzey sertliği bakımından yeterli etkinliği gösterememiştir.

Özet (Çeviri)

Aim: The aim of this study is to compare the effect of different polymerization times and acidic cycle on the surface hardness of composite resins. Materials and Methods: 4 different composite resins in the research; Using Filtek Ultimate universal flow (3M ESPE, USA), General universal flow (GC, JAPAN), Gradia Direct Anterior (GC, Tokyo, JAPAN) and Filtek Z250 (3M ESPE, USA) a total of 208 samples, 8 mm diameter and 2 mm thickness in were prepared. Each group was divided into two, to be held in two different drinks. These groups were also divided into two groups to be polymerized with different light modes. The samples were polymerized with the Valo Cordless LED (Ultradent, USA) light device in two different light modes (standard mode, extra power light mode) according to the manufacturer's instructions. Polymerized samples were kept in an oven at 37 ° C for 24 hours, and then polishing were carried out. The first microhardness measurements (Vickers, Duramin, Struers, USA) of the prepared samples were made. After the samples were kept in beverages with different acidic character and pH (cola, distilled water) for 28 days, microhardness measurements were repeated. Results: A statistically significant difference was observed between the average values of the hardness rates of the composites applied with Vicker's hardness test (p˂0.05). Gradia Direct Anterior composite resin is the most affected by its surface hardness as a result of being kept in different liquids, and it was detected in the samples of this group that were polymerized with extra power light mode and then kept in the coke. (p = 0.001). Regardless of drink while Filtek Z250 group shows the highest surface hardness values in all light modes, the Gradia Direct Anterior group has the lowest average hardness. Regardless of composites, coke among solutions caused a greater reduction in surface hardness than distilled water groups. The lowest hardness values were found in the samples where the extra power mode of the Valo light device was applied. Conclusion: Composite resins were affected by liquids at different rates depending on their composition. It has been noted that acidic beverages cause changes in the surface hardness values of resin-based restorative materials. The extra power mode of the Valo light device did not show enough efficiency in terms of surface hardness compared to the standard mode.

Benzer Tezler

  1. Ön ısıtma uygulanan kompozit rezinlerin mikrosertlik, yüzey pürüzlülüğü ve renk değişiminin incelenmesi

    Investigation of microhardness, surface roughness and color change of PRE-HEATED composite resins

    MALHUN BEGÜM ÇEKMEZ

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2022

    Diş HekimliğiSağlık Bilimleri Üniversitesi

    Restoratif Diş Tedavisi Ana Bilim Dalı

    PROF. DR. SERPİL KARAOĞLANOĞLU

  2. Farklı ışık cihazları ve farklı uygulama teknikleri ile polimerize edilen bir posterior kompozitin mikrosertlik, polimerizasyon büzülmesi ve polimerizasyon esnasinda açığa çıkan ısı açısından değerlendirilmesi

    The evaluation of microhardness, polymerization shrinkage and the heat released during polymerization of a posterior composite polymerized with different techniques and different light devices

    CİHAN ÖZ

    Doktora

    Türkçe

    Türkçe

    2014

    Diş HekimliğiDicle Üniversitesi

    Çocuk Diş Hekimliği Ana Bilim Dalı

    DOÇ. DR. BUKET AYNA

  3. Ön ısıtma ve farklı polisaj sistemleri kullanımının posterior kompozitlerin yüzey pürüzlülüğü ve sertliğine etkisi

    The effect of preheating and using of different polishing systems on surface roughness and hardness of posterior composites

    KANŞAD PALA

    Doktora

    Türkçe

    Türkçe

    2013

    Diş HekimliğiErciyes Üniversitesi

    Diş Hastalıkları ve Tedavisi Ana Bilim Dalı

    DOÇ. DR. YAHYA ORÇUN ZORBA

  4. Düşük polimerizasyon büzülmesi gösteren iki posterior kompozit rezinin in-vitro ve klinik olarak uzun dönemli karşılaştırılması

    Showing low shrinkage posterior composite resin two -vitro and clinical long-term comparison

    ESRA YILMAN RAHİMİ ALAGHA

    Doktora

    Türkçe

    Türkçe

    2013

    Diş HekimliğiEge Üniversitesi

    PROF. DR. FERİT ÖZATA

  5. Güncel bulk fill kompozitlerin konversiyon derecelerinin mikrosertlik yöntemiyle değerlendirilmesi

    Evaluation of the conversion degrees of current bulk fill composites using the microhardness method

    SERGEN ÖZDEMİR

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2023

    Diş HekimliğiAkdeniz Üniversitesi

    Restoratif Diş Tedavisi Ana Bilim Dalı

    PROF. DR. ÇAĞATAY BARUTÇUGİL