CBCT veya üç boyutlu laboratuvar tarayıcısından yararlanılarak CAD/CAM ile üretilen üç üyeli posterior zirkonyum restorasyon altyapılarının dikey marjinal uyumları bakımından karşılaştırılması
Vertical marginal discrepancy comparison of CBCT- and3-dimensional laboratory-fabricated CAD/CAM three unitzirconia posterior restoration frameworks
- Tez No: 658415
- Danışmanlar: YRD. DOÇ. DR. EDİZ KALE
- Tez Türü: Diş Hekimliği Uzmanlık
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Belirtilmemiş.
- Yıl: 2016
- Dil: Türkçe
- Üniversite: Mustafa Kemal Üniversitesi
- Enstitü: Diş Hekimliği Fakültesi
- Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Amaç Bu çalışmanın amacı; CBCT (Cone beam computerized tomography) veya 3B (3 boyutlu) laboratuvar tarama cihazı verisi kullanılarak CAD/CAM (Computer-aided-design/computer-aided-manufacturing) ile üretilen üç üyeli zirkonyum altyapılı posterior restorasyonları dikey marjinal açıklıkları (DMA) bakımından karşılaştırmalı olarak değerlendirmektir. Gereç ve Yöntem Çekilmiş sol ikinci premolar ve molar dişler maksiller modelde yerlerine yerleştirildi ve tam seramik restorasyonlarda kullanılan preparasyon kurallarına göre preparasyonları tamamlandı. Preparasyonu tamamlanan ve modele yerleştirilmiş dişler 3B laboratuvar tarama cihazı ve CBCT ile tarandı. Tarama sonucu elde edilen stereolitrografi formatındaki veriler farklı iki dijital model elde etmek üzere CAD yazılımına aktarıldı. Hazırlanan iki dijital model üzerine aynı parametreler kullanılarak 3 üyeli zirkonyum posterior restorasyon altyapıları tasarlandı. Tasarlanan altyapılar yarı sinterlenmiş zirkonyum bloklar kullanılarak 5-eksenli CAM sistemi ile üretildi. 3B laboratuvar tarama ve CBCT görüntü verileri kullanılarak, her grupta 22 örnek olacak şekilde üretim tamamlandı ve model üzerine elle uyumlandırıldı. Premolar ve molar dişler etrafında belirlenen 7'şer ölçüm noktasından, restorasyonların dikey marjinal açıklıklarını gözlemlemek için ×100 büyütmede ölçüm yapıldı. Ölçüm sonuçları değerlendirilerek her noktada DMA ortalamaları hesaplandı. Elde edilen veriler ile 2 grubun (% 80 güç için n=22) dikey marjinal uyumları Mann-Whitney U testi kullanılarak istatistiksel olarak karşılaştırıldı (α=0.05). Bulgular Her grupta 22 altyapı, her altyapıda 14 ölçüm noktası olmak üzere, 2 grupta toplam 616 noktadan ölçümler yapıldı. Her grup için en yüksek ve en düşük DMA ortalamaları hesaplandı. En düşük ve en yüksek DMA değerleri: premolar 3B-L grubu için 44 ve 55 µm; premolar CBCT grubu için 74 ve 100 µm; molar 3B-L grubu için 47 ve 114 µm; molar CBCT grubu için 91 ve 162 µm olarak hesaplandı. DMA ortalamalarının CBCT grubunda, 3B-L grubuna göre anlamlı derecede daha yüksek olduğu görüldü (P<0.001). Sonuçlar Bu in-vitro çalışmanın sınırları dikkate alınarak; 3B laboratuvar tarayıcısı verileri kullanılarak CAD/CAM ile üretilen 3 üyeli zirkonyum altyapıların DMA değerleri, CBCT verileri kullanılarak üretilen aynı tasarımlı restorasyonlara kıyasla anlamlı derecede az bulunmuştur. CBCT ile üretim tekniği, klinik kabul edilebilirlik açısından, umut verici sonuçlar ortaya koymuştur.
Özet (Çeviri)
Purpose The purpose of this in vitro study was to comparatively evaluate the vertical marginal discrepancy (VMD) of 3-unit CAD/CAM zirconia posterior restoration frameworks fabricated via CBCT or 3-dimensional (3D) laboratory scanner. Materials and Methods Tooth preparation was made on extracted left second premolar and molar tooth mounted on a maxillary typodont arch model, according to conventional preparation guidelines for all-ceramic crowns. The prepared teeth and the model were scanned with a 3-dimensional extra-oral laser scanner and a CBCT. The stereolithography formats of each scan were processed with a CAD software to create two separate digital models and a 3-unit-zirconia posterior-restoration framework with same structural parameters was designed for both. The designed framework was multiplied and milled from pre-sintered zirconia blocks in a 5-axis CAM unit. Twenty-two samples in a group (3D-L and CBCT) for each scanning method were manufactured and manually adapted on the typodont model. VMD of the restorations was digitally observed at ×100 magnifications in 7 pre-standardized measurement locations on each tooth. Measurements were done and means calculated for each location. The results were statistically compared between groups with 80% power (n=22) using Mann-Whitney U test (α=0.05). Results A total of 616 (2 groups, 22 frameworks per group, 14 locations per specimen) VMD measurements were performed in both groups with the lowest and highest mean results of 44 and 55 µm (premolar, 3D-L), 74 and 100 µm (premolar, CBCT), 47 and 114 µm (molar, 3D-L), and 91 and 162 µm (molar, CBCT) per location. The VMD for the CBCT group was significantly greater than the 3D-L group (P<0.001). Conclusion Within the limitations of this in vitro study, it was concluded that 3-unit CAD/CAM zirconia posterior restoration frameworks fabricated via 3-dimensional laboratory scanner had significantly lower VMD compared to CBCT. The CBCT fabrication technique presented promising results in terms of clinically acceptable application.
Benzer Tezler
- İki boyutlu ve üç boyutlu görüntüleme teknikleri kullanılarak planlanan hedef oluşturma geometrik sınırlarının (marj) istatistiksel hesaplanması
Statistical calculation of target creation geometric limits (marj) planned by using two-dimensional and three-dimensional imaging techniques
RUMEYSA GEYİK
Yüksek Lisans
Türkçe
2018
Fizik ve Fizik MühendisliğiAkdeniz ÜniversitesiFizik Ana Bilim Dalı
DR. ÖĞR. ÜYESİ ŞERAFETTİN YALTKAYA
- Mini-vida destekli hızlı üst çene genişletmesi ile konvansiyonel hızlı üst çene genişletmesinin etkilerinin konik ışınlı bilgisayarlı tomografi (CBCT) kullanılarak karşılaştırılması
Comparison of the effects of conventional rapid palatal expansion and mini-screw supported rapid palatal expansion using cone beam computed tomography (CBCT)
GÖZDE TUĞÇE ÇELENK KOCA
Doktora
Türkçe
2013
Diş HekimliğiEge ÜniversitesiOrtodonti Ana Bilim Dalı
PROF. DR. ASLIHAN MEDİHA ERDİNÇ
- Posterior maksillada yeterli kemik hacminin olmadığı durumlarda implant uygulamasında kuvvet dağılımlarının sonlu elemanlar analizi ile incelenmesi
Finite element analysis of stress distribution around ımplants applied in atrophic posterior maxilla
BRUNILDA GASHI
Doktora
Türkçe
2009
Diş Hekimliğiİstanbul ÜniversitesiOral İmplantoloji Ana Bilim Dalı
PROF. DR. TAYFUN ÖZDEMİR
- Ortognatik cerrahi hastalarında maksilla mandibula hareketlerine göre preoperatif ve postoperatif konik ışınlı bilgisayarlı tomografi ile kondil konumunun değerlendirilmesi
Evaluation of condylar position according to maxillary–mandibular movements in orthognathic surgery patients using preoperative and postoperative cone-beam computed tomography
SERDAR DEMİR
Diş Hekimliği Uzmanlık
Türkçe
2025
Diş HekimliğiAtatürk ÜniversitesiAğız, Diş ve Çene Cerrahisi Ana Bilim Dalı
PROF. DR. ÜMİT ERTAŞ
- Farklı tasarımlardaki zigoma plaklarının intrüzyon ve protrüzyon kuvvetleri karşısındaki stres birikimlerinin sonlu elemanlar analizi ile değerlendirilmesi
Evaluation of stress accumulation in zygomatic plates of different designs under intrusion and protraction forces using finite element analysis
BERİL İĞDİR DİKER