İki boyutlu ve üç boyutlu görüntüleme teknikleri kullanılarak planlanan hedef oluşturma geometrik sınırlarının (marj) istatistiksel hesaplanması

Statistical calculation of target creation geometric limits (marj) planned by using two-dimensional and three-dimensional imaging techniques

  1. Tez No: 541212
  2. Yazar: RUMEYSA GEYİK
  3. Danışmanlar: DR. ÖĞR. ÜYESİ ŞERAFETTİN YALTKAYA
  4. Tez Türü: Yüksek Lisans
  5. Konular: Fizik ve Fizik Mühendisliği, Physics and Physics Engineering
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2018
  8. Dil: Türkçe
  9. Üniversite: Akdeniz Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Fizik Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 55

Özet

Çalışmada, Baş-Boyun kanseri hastalarının radyasyon tedavisinde X-ışınlarıyla iki boyutlu (2B) ve üç boyutlu (3B) Konik Huzmeli Bilgisayarlı Tomografi (CBCT) görüntüleri ile belirlenen set-up (kurulum) hatalarının tespiti ve karşılaştırılması yapılmıştır. Karşılaştırma sonuçlarıyla Planlanan Hedef Hacim (PTV) oluşturma marjlarının yeterliliği istatistiksel olarak araştırılması amaçlanmıştır. Bu çalışmada baş-boyun kanseri hastalarının Hacimsel Yoğunluk Ayarlı Ayarlı Ark Terapi (VMAT) planlamaları için kV enerji mertebesinde 2B ve 3B-CBCT ile belirlenen set-up hataları karşılaştırıldı. Bunun için on baş-boyun kanseri hastasının Görüntü Eşliğinde Radyasyon Tedavisi (IGRT) süreçlerinde elde edilen kV enerji seviyesindeki iki boyutlu ve üç boyutlu CBCT görüntüleri incelendi. Tüm VMAT tedavileri Elekta Versa HD Lineer Hızlandırıcı cihazında uygulandı. Lineer hızlandırıcıya monte edilen X- ışını tüpü ve detektörden oluşan görüntüleme sistemi kullanılarak 2B ve 3B'de hastanın tomografik görüntüleri kullanıldı. AP (x), RL (y) ve SI (z) koordinatlarındaki set-up hataları belirlenerek, tedavi sırasında çevrim içi düzeltme protokolü uygulanarak bulunmuş olan x, y, z koordinatlarındaki set-up hataları ayrı ayrı incelendi. Görüntülemelerle yapılan eşleştirmelerden elde edilen tedavi masası kaydırma değerleri kullanılarak PTV marjları tüm hastalarda hesaplanmıştır. Hesaplanan marjlar her iki görüntüleme yönteminde 2,8-3,8 mm arasında bulundu. On baş-boyun hastası için iki boyutlu ve üç boyutlu görüntüleri kullanarak CTV' ye verilmesi gereken PTV marj değeri RL (sağ-sol), SI (Superior- inferior ) ve AP (Anterior- Posterior) yönlerinde 0,5 cm'nin altında bulunmuş olup klinikte verilen marjların yeterli olduğu sonucuna ulaşılmıştır. Ancak toplam tedavi sürecinde görüntüleme tekrarının protokolü, kV-kV veya kV-CBCT görüntüleme işlemleri nedeniyle hastaya verilen ek radyasyon dozun değerlendirilmesi göz önünde bulundurulmalıdır.

Özet (Çeviri)

In the study, the determination and comparison of set-up errors by twodimensional (2D) and three-dimensional (3D) Conic Beam Computed Tomography (CBCT) images in the X-rays treatment of head and neck cancer patients were performed. It is aimed to statistically investigate the adequacy of the Planned Target Volume (PTV) margin by comparing with results. In this study, the defined set-up errors by 2D and 3D-CBCT at kV energy level were compared for VMAT treatment of head and neck cancer patients. For this purpose, the acquisition of 2D and 3D-CBCT images of the kV energy level in the radiation treat ment (IGRT) processes for ten head and neck cancer patients were performed and exami ned. All VMAT treatments were done at Elekta Versa HD Linear Accelerator device. The 2D and 3D images of the patient were used by imaging system consisting of the X-ray tube and detector that mounted on the linear accelerator. Set-up errors in AP (x), RL (y) and SI (z) directions were separately determined according to x, y and z coordinate system by online correction protocol during the treatment. PTV margins were calculated for all patients using the treatment table shift values obtained from the matches with the images. Calculated margins were found to be 2.8-3.8 mm from both imaging methods. PTV margin value to be given to CTV using two-dimensional and threedimen sional images for ten head and neck patients was found to be less than 0.5 cm in RL (right-left), SI (Superior-inferior) and AP (Anterior-Posterior) directions and it is concluded that the margins given in the clinic are sufficient. However, during the total treatment process, the evaluation of the imaging radiation, the evaluation of the addi -tional radiation dose given to the patient due to kV-kV or kV-CBCT imaging procedure should be considered.

Benzer Tezler

  1. Mide kanserinin tedavisinde uygulanan yoğunluk ayarlı radyoterapi planlama sistemi ile 3D konformal radyoterapi sisteminde kritik organ dozlarının karşılaştırılması

    Comparison of dose distrubution for critical organs with intensitiy modulated radiation therapy and 3D conformal radiotherapy for gastric cancer

    KUDRET BEKTAŞ

    Yüksek Lisans

    Türkçe

    Türkçe

    2016

    OnkolojiGaziantep Üniversitesi

    Radyasyon Onkolojisi Ana Bilim Dalı

    YRD. DOÇ. DR. ABDURAHMAN KUZHAN

  2. Rektum kanseri tedavisinde yoğunluk ayarlı radyoterapi planlamaları ile 3 boyutlu konformal radyoterapi planlamalarının doz dağılımlarının karşılaştırılması

    Comparison of dose distribution with intensity modulated radiation therapy and 3 dimensional conformal radiotherapy for rectum cancer

    ŞULE BAZ ÇİFCİ

    Yüksek Lisans

    Türkçe

    Türkçe

    2011

    OnkolojiHacettepe Üniversitesi

    Radyasyon Onkolojisi Ana Bilim Dalı

    PROF. DR. MUSTAFA CENGIZ

  3. Glioblastoma multiforme (GBM) beyin tümörü tedavisinde üç boyutlu konformal radyoterapi ve yoğunluk ayarlı radyoterapi tekniklerinin karşılaştırılması

    Comparison of three dimensional conformal radiotherapy and intensity modulated radiotherapy techniques in glioblastoma multiforme (GBM) brain tumors

    SALİH GÖRÜR

    Yüksek Lisans

    Türkçe

    Türkçe

    2012

    Fizik ve Fizik MühendisliğiAnkara Üniversitesi

    Medikal Fizik Ana Bilim Dalı

    DOÇ. DR. BAHAR DİRİCAN

  4. Prostat kanseri tedavisinde alan içinde alan yoğunluk ayarlı radyoterapi ve üç boyutlu konformal radyoterapi tedavi planlarının dozimetrik olarak değerlendirilmesi

    Dosimetric evaluation of field-in-field intensity modulated radiotherapy and 3D-conformal therapy techniques in prostate cancer radiotherapy

    SERHAT ETLİ

    Yüksek Lisans

    Türkçe

    Türkçe

    2021

    Radyasyon OnkolojisiSağlık Bilimleri Üniversitesi

    Radyasyon Onkolojisi Ana Bilim Dalı

    PROF. DR. BAHAR DİRİCAN

  5. Mobile robots

    Başlık çevirisi yok

    BİLİN AKSUN

    Yüksek Lisans

    İngilizce

    İngilizce

    1996

    Makine Mühendisliğiİstanbul Teknik Üniversitesi

    PROF.DR. N. AYDIN HIZAL