Geri Dön

Çise distalizasyon apareyinin etkinliğinin incelenmesi

Examination of the effectiveness of the cise distalization appliance

  1. Tez No: 674230
  2. Yazar: SONER ARUSOĞLU
  3. Danışmanlar: DOÇ. DR. NURHAT ÖZKALAYCI
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Diş hareketleri, Maloklüzyon-angle sınıf II, Mini vidalar, Ortodonti, Ortodonti-düzeltici, Ortodontik aygıtlar, Ortodontik teller, Tooth movement, Malocclusion-angle class II, Mini screws, Orthodontics, Orthodontics-corrective, Orthodontic appliances, Orthodontic wires
  7. Yıl: 2020
  8. Dil: Türkçe
  9. Üniversite: Zonguldak Bülent Ecevit Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Ortodonti Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu çalışmanın amacı iskeletsel ankraj ünitesine sahip, iki adet Ni-Ti açık sarmal yay içeren, üst molar tüpüne uygulanan yeni bir distalizasyon apareyinin etkinliğinin in vitro olarak değerlendirilmesidir. Apareylerin yerleştirilmesi için 11 adet çalışma modeli elde edilmiştir. Bu modellerin 7'sine tek taraflı 4'üne çift taraflı olarak Çise distalizasyon apareyi yerleştirilmiştir. Toplamda 15 adet Çise distalizasyon apareyi incelenmiştir. Birinci yay ve ikinci yay olarak adlandırılan iki adet Ni-Ti açık sarmal yay içeren apareyler iki adet mini vidaya ve molar tüpüne yerleştirilmiştir. Molar tüplerinin üzerine yerleştirilen strain gauge yardımıyla apareyin ürettiği kuvvetler ölçülmüştür. Birinci yayın ve/veya ikinci yayın 3 mm, 6 mm, 9 mm ve tam aktivasyonu sonucu ortaya çıkan kuvvet değerlerine göre apareyin etkinliği değerlendirilmiştir. Apareyin ürettiği kuvvet miktarı yayların aktivasyonlarına göre değiĢkenlik göstermiştir. Birinci yay ve ikinci yayın eşit aktivasyonlarda ürettiği kuvvet değerlerinin büyük bir çoğunluğunda istatistiksel olarak anlamlı farklılık bulunmamıştır. Her iki yayın beraber aktivasyonuyla tek bir yayın aynı aktivasyonuna göre daha yüksek kuvvet değerleri elde edilmiştir. Bu farklılıklar istatistiksel olarak anlamlı bulunmuştur (p<0.05). Aparey tek taraflı 960 grama kadar kuvvet sağlayabilmektedir. Bu çalışmanın sonucunda sunulan aparey tarafından üst molar dişlerin distalizasyonu için gerekli olan kuvvetin sağlanabileceği in vitro olarak kanıtlanmıştır. Klinik çalışmaların önü açılmıştır.

Özet (Çeviri)

The aim of this study is to evaluate in vitro the effectiveness of a new distalization appliance with a skeletal anchorage unit and two Ni-Ti open coil springs applied to the upper molar tube. 11 study models were obtained for the placement of the appliance. Cise distalization appliance was placed unilaterally on 7 of these models, and on 4 of these models bilaterally. A total of 15 Cise distalization appliances were evaluated. The appliance containing two Ni-Ti open coil springs called the first spring and the second spring are placed in two mini screws and molar tube. The forces produced by the appliance were measured with the help of strain gauge placed on molar tubes. The effectiveness of the appliance was evaluated according to the force values of the first spring and/or the second spring 3 mm, 6 mm, 9 mm and its full activation. The amount of force generated by the appliance varied according to the activation of the springs. No statistically significant difference was found in the majority of the force values produced by the first spring and the second spring at equal activations (p<0.05). With the joint activation of both springs, higher force values were obtained compared to the same activation of a single spring. These differences were found to be statistically significant (p<0.05). The appliance can provide up to 960 grams of force on one side. As a result of this study, it has been proven in vitro that the force required for the distalization of the upper molar teeth can be provided by the appliance presented. This study will be a guide for clinical studies.

Benzer Tezler

  1. Maksillada kullanılan farklı geometrilerdeki mikroimplantların sonlu elemanlar analiz yöntemi ile üç boyutlu incelenmesi

    Three dimensional evaluation of microimplants with different geometries inserted to maxillary bone by using finite element analysis study

    İDİL BAVBEK KARAKAYA

    Doktora

    Türkçe

    Türkçe

    2011

    Diş HekimliğiGazi Üniversitesi

    Ortodonti Ana Bilim Dalı

    PROF. DR. NİLÜFER DARENDELİLER

  2. Direkt ve indirekt dijitalizasyon ile üretilen 5 üyeli monolitik zirkonya restorasyonların marjinal ve internal uyumunun 3 boyutlu karşılaştırması: İn vitro çalışma

    Comparison of marginal and internal fit of 5-unit monolithic zirconia fixed dental prostheses made with direct and indirect digitalization: An in vitro study

    İREM GÖKÇE ULUÇ

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2020

    Diş HekimliğiHacettepe Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    DOÇ. DR. MUSTAFA BARIŞ GÜNCÜ

  3. Örgüt ikliminin iş tatmini üzerine etkisi: Bir uygulama

    Effects of organisational climate on job satisfaction : A survey study

    ÇİSE DOĞAN

    Yüksek Lisans

    Türkçe

    Türkçe

    2009

    Çalışma Ekonomisi ve Endüstri İlişkileriMarmara Üniversitesi

    Çalışma Ekonomisi ve Endüstri İlişkileri Ana Bilim Dalı

    PROF. DR. PINAR TINAZ

  4. Hafif ticari araçlarda maliyet azaltma amaçlı ayna mahruti malzemesi değişikliği

    Cost reduction oriented hypoid gear material optimization in commercial vehicles

    ÇİSE ÖZKAYA

    Yüksek Lisans

    Türkçe

    Türkçe

    2010

    Makine Mühendisliğiİstanbul Teknik Üniversitesi

    Malzeme ve İmalat Bilim Dalı

    DOÇ. DR. CEMAL BAYKARA

  5. Ortognatik cerrahi uygulanan hastalarda postoperatif memnuniyetin değerlendirilmesi

    Evaluation of postoperative patient satisfaction after orthognathic surgery

    ÇİSE ÇAĞIN

    Doktora

    Türkçe

    Türkçe

    2013

    Diş HekimliğiGazi Üniversitesi

    Ağız, Diş ve Çene Cerrahisi Ana Bilim Dalı

    PROF. DR. ZİVER ERGÜN YÜCEL