Maksillada kullanılan farklı geometrilerdeki mikroimplantların sonlu elemanlar analiz yöntemi ile üç boyutlu incelenmesi
Three dimensional evaluation of microimplants with different geometries inserted to maxillary bone by using finite element analysis study
- Tez No: 288714
- Danışmanlar: PROF. DR. NİLÜFER DARENDELİLER
- Tez Türü: Doktora
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Belirtilmemiş.
- Yıl: 2011
- Dil: Türkçe
- Üniversite: Gazi Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Ortodonti Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: 353
Özet
Çalışmanın amacı; farklı tedavi seçeneklerinde, ortodontik ankraj amaçlı kullanılan farklı geometrilerdeki mini vidaların üzerine uygulanan kuvvetler sonucunda, vida ve çevresindeki kemik yapı üzerinde oluşan stresi sonlu elemanlar analizi ile 3 boyutlu değerlendirmektir. Bu çalışma mini-vidaların geometrik farklılığının çevre kemik dokuya iletilen kuvveti etkilediği hipotezi üzerine kurulmuştur.Üç boyutlu olarak modellenen maksiller kemik üzerindeki analizler üç tip mini-vida kullanılarak yapılmıştır; Neo-anchor plus (anchor plus, USA) 1.6x8 mm; A vidası, O.S.A.S (Dewimed, Germany) 1.6x8 mm; B vidası ve Spider Screw (HDC Company, Italy) 2x8 mm; C vidası olarak senaryolarda tanımlandı.Senaryo 1'de, vidalar kanin retraksiyonu amacı ile yerleştirildi ve 1 N kuvvet uygulandı. Senaryo 2'de, vidalar molar distalizasyonu amacı ile yerleştirildi ve 2.5 N'luk kuvvet uygulandı. Senaryo 3'de vidalar, keser intrüzyonu amacıyla yerleştirildi ve 1 N'luk kuvvet uygulandı. Senaryo 4'de vidalar keser intrüzyonu amacıyla yerleştirildi ve 0.5 N'luk kuvvetler uygulandı. Senaryo 5'de vidalar bölgesel molar distalizasyonu amacıyla yerleştirildi ve 2.5 N'luk kuvvet uygulandı.Vidalar üzerinde kaydedilen en düşük von Misses stres değeri, tüm senaryolarda C vidasında görüldü. Kortikal kemik üzerinde kaydedilen en düşük von Misses stres seviyesi senaryo 4 hariç diğer tüm senaryolarda A vidası kullanıldığında saptandı.Vidalar üzerinde oluşan en yüksek von Misses stres değerleri vidanın boyun kısmında, kortikal kemik hizasına denk gelen ilk yivleri üzerinde görüldü, kemik üzerinde kaydedilen en yüksek von Misses stres değeri kortikal kemik yüzeyinde, vidanın yerleştirildiği bölgede görüldü.Mini-vida üzerinde stres değerinin en fazla olduğu vidanın boyun kısmında yiv sayısının arttırılması/adım mesafesinin azaltılması kortikal kemik üzerindeki stresi, mini-vida çapının arttırılması ise vida üzerindeki von Misses stres miktarını azaltmıştır.
Özet (Çeviri)
The aim of this study was to investigate the stress disturibition on the screws and the surrounding bone as a result of the force application on the screws with different geometries used for orthodontic anchorage for different treatment modalities in three dimensions by using finite element analysis. This study based on the hypothesis that the geometric differences of miniscrews can affect the force transmitted to the surrounding bone tissue.The analysis on the 3-d modeled maxillary bone was performed by using three type of mini-screws; Neo-anchor plus (anchor plus, USA) 1.6x8 mm; Screw A, O.S.A.S (Dewimed, Germany) 1.6x8 mm; Screw B and Spider Screw (HDC Company, Italy) 2x8 mm; Screw C as defined in scenarios.In scenario 1th screws were insert for the canine retraction and 1 N force was applied. In scenario 2nd screws were inserted for the molar distalisation and 2.5 N force was applied. In scenario 3rd screws were inserted for intrusion of the incisors, and 1 N force was applied. In scenario 4th screws were inserted for intrusion of the incisors, and 0.5 N force was applied. In scenario 5th screws were inserted for the sectional molar distalisation and 2.5 N force was applied.The lowest von Misses stress values for the screws were found on screw C in all scenarios. The lowest Von Misses stress for cortical bone was recorded when screw A was used in all scenarios except scenario 4.The highest values of von Misses stress on the screws were recorded at the neck of the screws, on the first piches which corresponded to the cortical bone level. As for the bone tissue, the highest von Misses stress value was recorded on the cortical bone where the screw was inserted.Increasing the number of threats or reducing the pitch at the neck of the screws, where the maximum stress were recorded, resulted with a decrease in the von Misses stress in cortical bone whereas increasing the diameter of the mini-screw decreased the von Misses stres in the screw itself.
Benzer Tezler
- Atrofik total dişsiz maksillada kullanılan titanyum ve peek materyalinden üretilmiş farklı subperiosteal implant tasırımlarının çevre dokulardaki biyomekanik etkilerinin sonlu elemanlar analizi kullanılarak incelenmesi
Investigation of the biomechanical effects of different subperiosteal implant designs made of titanium and peek materials used in atrophic total edentulous maxilla on the surrounding tissues using finite element analysis
TURGAY KASAP
Diş Hekimliği Uzmanlık
Türkçe
2024
Diş HekimliğiHacettepe ÜniversitesiAğız, Diş, Çene Hastalıkları ve Cerrahisi Ana Bilim Dalı
DOÇ. DR. MUSTAFA YİĞİT SAYSEL
- Anterior maksillaya yerleştirilen implantlarda kullanılan farklı açılardaki abutmentlarda okluzal yüklemeler sonucu oluşan kuvvet dağılımlarının sonlu elemanlar stres analizi yöntemi ile incelenmesi
Evaluation of stress distribution around anterior maxiller implants for different abutment angulations under occlusal loading by finite element analysis
ZEYNEP YEĞİN
Doktora
Türkçe
2016
Diş HekimliğiAnkara ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
PROF. DR. YÜKSEL TÜRKÖZ
- Mandibular implant üstü tam protezlerde kullanılan farklı ataçman tiplerinin alveoler kemik rezorpsiyonuna etkisinin radyografik olarak değerlendirilmesi
The radiographic evaluation of the effect of different attachments types used in mandibular implant-retained overdentures, on residuel ridge resorption
EMEL KIRAÇ
Doktora
Türkçe
2013
Diş HekimliğiErciyes ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
DOÇ. DR. MUSTAFA ZORTUK
- Sınıf III maloklüzyonların tedavisinde kullanılan yüz maskesi, kemik destekli maksiller protraksiyon ve hibrid hyrax+mentoplate kombinasyon yöntemlerinin biyomekanik etkilerinin sonlu elemanlar analiziyle incelenmesi
Evaluation of the biomechanical effects of the facemask, bone assisted maxillary protraction and hybrid hyrax + mentoplate combinations method used in the treatment of class iii malocclusions with three dimensional finite element stress analysis
SERHAT ÖZDEMİR
Diş Hekimliği Uzmanlık
Türkçe
2018
Diş HekimliğiGaziantep ÜniversitesiOrtodonti Ana Bilim Dalı
YRD. DOÇ. DR. MERVE GÖYMEN
- Büyüme faktörleri içeren fibrin ağının sinüs ogmentasyonundaki etkinliğinin klinik, histolojik ve histomorfometrik analizi
Başlık çevirisi yok
İHSAN ÇAĞLAR ÇİNAR
Doktora
Türkçe
2019
Diş Hekimliğiİstanbul ÜniversitesiOral İmplantoloji Ana Bilim Dalı
PROF. DR. SERDAR YALÇIN