Ekstraoral implantlarda yeni anti-manyetik dayanak tasarımının tutuculuğa etkisinin in-vitro incelenmesi

In-vitro investigation of the effect of A new anti-magnetic abutment design on the retention in extraoral implants

  1. Tez No: 674705
  2. Yazar: İREM SÖZEN YANIK
  3. Danışmanlar: PROF. DR. BAHADIR ERSU
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Dental bonding, Dental destekler, Dental implantasyon, Dental implantlar, Protezler ve implantlar, Yüz, Çene, İmplantasyon, İn vitro, Dental bonding, Dental abutments, Dental implantation, Dental implants, Prostheses and implants, Face, Jaw, Implantation, In vitro
  7. Yıl: 2021
  8. Dil: Türkçe
  9. Üniversite: Hacettepe Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Mıknatıs ataçmanlar, maksillofasiyal protezlerde yaygın olarak kullanılmaktadır. Mıknatıs tutucuların pek çok avantajının yanı sıra, manyetik dayanakların, manyetik rezonans görüntülemede (MRG) çıkarılmasının gerekliliği ve hücreler üzerindeki olumsuz etkileri gibi dezavantajları da vardır. Bu in-vitro çalışmanın amacı, rutinde kullanılan manyetik dayanaklara alternatif olarak geliştirilmiş yeni tip anti-manyetik dayanak tasarımların tutuculuğunu değerlendirmektir. Bu amaçla Ti6Al4V alaşımından üretilen yeni tip anti-manyetik dayanakların, güncel kullanımda olan ekstraoral implantlara göre, tutuculukları karşılaştırılmıştır. Çalışmada 4 grup belirlenmiştir ve her gruptan 10'ar örnek hazırlanmıştır. 1. grup geleneksel manyetik sistem (GMS-kontrol grubu), 2. grup bu geleneksel manyetik sistemin 100°C'de ısıtılmış hali (IGMS), 3. grup anti-manyetik dayanak tip 1 sistemi (AMS1) ve 4. grup da tip 2 sistemidir (AMS2). Örnekler, test sistemi hazırlandıktan sonra sırasıyla test sistemine yerleştirilmiştir. 0, 120, 360, 720, 1440. döngülerdeki tutuculuk kuvvetleri ölçülmüştür. Tutuculuk değerleri 1440 döngü sonucunda sırası ile GMS: 3,39 N, IGMS: 3,38 N, AMS1: 8,83 N, AMS2: 8,75 N olarak ölçülmüştür. Sonuçların değerlendirilmesi ve farklı dayanak-ataçman sistemlerinin çıkarma kuvvetlerinin karşılaştırılmasında Two way ANOVA repeated measures kullanılmıştır. AMS grupları kendi içinde ve GMS grupları kendi içinde benzer sonuçlar göstermiştir (p>0,05). GMS ve AMS1, GMS ve AMS2 arasında ise istatistikler olarak anlamlı farklılık bulunmuştur (p<0,05). Sonuç olarak, yeni tip anti-manyetik dayanakların tutuculuk kuvvetlerinin daha yüksek değerlerde olduğu ve manyetik dayanaklara bir alternatif olabileceği görülmüştür.

Özet (Çeviri)

Magnet attachments are widely used in maxillofacial prostheses. In addition to many advantages of magnet attachments, there are also disadvantages such as the need to remove the magnetic abutments during the magnetic resonance imaging (MRI) and their negative effects on cells. This in-vitro study aims to evaluate the retention of new types of anti-magnetic abutment designs developed as an alternative to routinely used magnetic abutments. For this purpose, the retention of the new type of anti-magnetic abutments produced from Ti6Al4V alloy were compared to the extraoral implants currently in use. 4 groups were determined in the study and 10 samples were prepared for each group. 1st group is conventional magnetic system (GMS-control group), 2nd group conventional magnetic system heated at 100 ° C (IGMS), 3rd group anti-magnetic abutment type 1 system (AMS1) and 4th group anti-magnetic abutment type 2 system (AMS2). The samples were placed in the test system, after the test system was prepared. The dislodging forces were measured at cycles 0, 120, 360, 720, 1440. The retention values were measured as GMS: 3.39 N, IGMS: 3.38 N, AMS1: 8.83 N, AMS2: 8.75 N at the end of 1440 cycles, respectively. Two way ANOVA repeated measures were used to evaluate the results and compare the extraction forces of different abutment-attachment systems. AMS groups and GMS groups showed similar results within themselves (p> 0.05). A statistically significant difference was found between GMS and AMS1, GMS and AMS2 (p <0.05). As a result, it has been observed that the retention strength of the new type of anti-magnetic abutments has higher values and can be an alternative to magnetic abutments.

Benzer Tezler

  1. Ağız dışı kuvvet (cervical headgear) uygulamalarında dentoalveoler değişikliklerin araştırılması

    İnvestigation of dentoalveoler changes in extraoral force (cervical headgear) applications

    A.MERAL IŞIK BİLDİR

    Doktora

    Türkçe

    Türkçe

    1990

    Ankara Üniversitesi

    Ortodonti Ana Bilim Dalı

    Yükleniyor...

  2. Aktivatör ve aktivatör+oksipital headgear ile tedavi edilmiş iskeletsel KL II anomalili bireylerde yumuşak doku değişikliklerinin incelenmesi

    Investigation of soft tissue changes in individuals with skeletal C1 II anomaly treated with activator or activator+HG

    ŞEBNEM PARLAR

    Doktora

    Türkçe

    Türkçe

    1988

    Ankara Üniversitesi

    Ortodonti Ana Bilim Dalı

    Yükleniyor...

  3. Manyetik kuvvetler yardımı ile üst birinci molar distalizasyonunun incelenmesi

    Başlık çevirisi yok

    ERAY ERDOĞAN

    Doktora

    Türkçe

    Türkçe

    1990

    Hacettepe Üniversitesi

    Ortodonti Ana Bilim Dalı

    Yükleniyor...