Geri Dön

Controlling the seismic behaviour of exterior reinforced concrete frame joints with relacated beam plastic hinges

Dış çerçeve birleşiminin deprem davranışının kiriş mafsalı ile kontrol edilmesi

  1. Tez No: 68744
  2. Yazar: EMRE BAŞARAN
  3. Danışmanlar: PROF. DR. FUAT ERBATUR
  4. Tez Türü: Yüksek Lisans
  5. Konular: İnşaat Mühendisliği, Civil Engineering
  6. Anahtar Kelimeler: plastik mafsal, kiriş-kolon birleşim bölgeleri, öndöküm bağlantılar, sismik davranış vi, Plastic hinge, beam-column joint, precast connection, seismic behaviour IV
  7. Yıl: 1997
  8. Dil: İngilizce
  9. Üniversite: Orta Doğu Teknik Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: İnşaat Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 165

Özet

ÖZ DIŞ ÇERÇEVE BİRLEŞİMİNİN DEPREM DAVRANIŞININ KİRİŞ MAFSALI İLE KONTROL EDİLMESİ Başaran, Emre Yüksek Lisans, İnşaat Mühendisliği Bölümü Tez Yöneticisi: Prof. Dr. Haluk Sucuoğlu Ortak Tez Yöneticisi: Doç. Dr. Güney Özcebe Temmuz 1997, 148 sayfa Bu araştırma programında kiriş plastik mafsal kapasitesinin birleşim davranışına olan etkileri incelenmiştir. Bu amaçla bir çerçeveye ait altı dış birleşim deney elemanı test edilmiştir. Bu elemanlardan üç tanesi bir döküm olarak hazırlanmıştır. Kuru bir birleşim detayı ile tasarlanan diğer üç eleman ise prefabrik olarak üretilmiştir. Her iki deney elemanı seti konvansiyonel olarak tasarlanmış birer ve yeni bir tasarım yaklaşımının kullanıldığı ikişer elemandan oluşmuştur. Yeni tasarım yaklaşımıyla amaçlanan, plastik mafsallaşma bölgesinin kiriş-kolon arayüzünden uzaklaştırılması ve birleşim bölgesinin tersinir yükleme altında elastik davranışının sağlanmasıdır. Bu yaklaşımla tasarlanan deney elemanlarında kiriş üst ve alt boyuna donatılan 45 derece bükülmüş ve böylece seçilen bölgede moment kapasitesi azaltılmıştır. Bu donatı detayını kullanan deney elemanlarında kapasite azatlımı miktarı değişken olarak seçilmiştir. Deney elemanlarının davranışları birbirleriyle dayanım, rijitlik ve enerji tüketimi açısından karşılaştırılmıştır. Prefabrik numuneler ani olarak kırılmış ve kirişte mafsaloluşturmanın etkileri bu elemanlarda gözlemlenememiştir. Fakat bir döküm elemanların deneyleri plastik mafsal ötelemesinin birleşim bölgesindeki gerilmeleri azalttığını göstermiştir. Test sonuçlan % 30-35 arası bir kapasite azaltanının başarılı bir davranış için yeterli olduğunu göstermiştir. Fakat belirli tasarım kurallarının ortaya konulabilmesi için daha fazla deneysel çalışmaya ihtiyaç vardır.

Özet (Çeviri)

ABSTRACT CONTROLLING THE SEISMIC BEHAVIOUR OF EXTERIOR REINFORCED CONCRETE FRAME JOINTS WITH RELOCATED BEAM PLASTIC HINGES Başaran, Emre M.S., Department of Civil Engineering Supervisor: Prof. Dr. Haluk Sucuoğlu Co-Supervisor: Assoc. Prof. Güney Özcebe July 1997, 148 pages Effect of relocating beam plastic hinging zone is investigated in this study. For this purpose six exterior joint sub-assemblies of a frame were tested. Three of the sub assemblies were monolithic, whereas the other three sub-assemblies utilizing a dry connection detail were precast specimens. Both monolithic and precast sets had one conventionally designed specimen and two specimens designed with a modified approach. It was aimed to relocate the potential plastic hinging zone away from the beam-column interface, hence ensure elastic joint behaviour throughout the reversed loading cycles. In the specimens designed with this approach, top and bottom beam bars were bent 45 degrees to reduce the moment capacity at the selected location. The variable among the two specimens of monolithic and precast sets which utilizes this design scheme was the amount of capacity reduction in the beam flexural capacity. The behaviour of the specimens was compared in terms of strength, stiffness, and energy dissipation. Due to the unexpected brittle failure of the precast specimens, inthe effect of relocating the beam plastic hinging zone on their joint behaviour could not be observed. However, the test results for the monolithic specimens indicated that the shear streses at the joint, hence the shear capacity demand were significantly reduced when the plastic hinge formed away from the joint. The test results indicated that flexural capacity reduction of 30-35% is optimum for satisfactory performance. However, it is necessary to conduct more studies to implement specific design recommendations.

Benzer Tezler

  1. A study of wind and seismic loads for curtain wall system: case studies in Istanbul

    Giydirme cephe sistemleri için rüzgar ve deprem yükü çalışması: istanbul'da vaka çalışmaları

    RUSUL SAAD ALI INIZI

    Yüksek Lisans

    İngilizce

    İngilizce

    2021

    Mimarlıkİstanbul Teknik Üniversitesi

    Mimarlık Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ CENK ÜSTÜNDAĞ

  2. Mevcut betonarme bir konut yapısının deprem performansının değerlendirilmesi ve çelik çaprazlarla güçlendirilmesi

    Seismic performance assessment of an existing reinforced concrete structure and strengthening with steel braces

    ALİ ERDEM KULAK

    Yüksek Lisans

    Türkçe

    Türkçe

    2013

    İnşaat Mühendisliğiİstanbul Teknik Üniversitesi

    İnşaat Mühendisliği Ana Bilim Dalı

    DOÇ. DR. ELİŞAN FİLİZ PİROĞLU

  3. Marmara Bölgesi'nde soğurulma yapısının incelenmesi

    Investigation of attenuation structure in the Marmara region

    AYŞE KAŞLILAR ÖZCAN

    Doktora

    Türkçe

    Türkçe

    1999

    Jeofizik Mühendisliğiİstanbul Teknik Üniversitesi

    DOÇ.DR. AYSUN BOZTEPE GÜNEY

  4. Armutlu yarımadası kuzeyi dip morfolojisi ve multi beam sonar veri işlem teknikleri

    Seafloor morphology of the northern Armutlu peninsula and multi beam sonar data processing techniques

    AHMET EMRE BASMACI

    Yüksek Lisans

    Türkçe

    Türkçe

    2003

    Jeofizik Mühendisliğiİstanbul Teknik Üniversitesi

    Jeofizik Mühendisliği Ana Bilim Dalı

    DOÇ. DR. BERKAN ECEVİTOĞLU