Konik ışınlı bilgisayarlı tomografinin kemik dansitesi ölçüm doğruluğunun değerlendirilmesi

Evaluation of bone density measurement accuracy of cone beam computer tomography

  1. Tez No: 688355
  2. Yazar: MEHMET AKGÜL
  3. Danışmanlar: DR. ÖĞR. ÜYESİ ONUR EVREN KAHRAMAN
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Konik ışınlı bilgisayarlı tomografi, yerleştirme torku, osstell RFA, bilgisayarlı tomgrafi, Hounsfield Unit, Kemik dansitesi, Tomografi-x ışınlı-bilgisayarlı, Ölçümleme, Cone beam computed tomography, insertion torque, osstell RFA, computed tomography, Hounsfield Unit, Bone density, Cone-beam computed tomography, Tomography-x ray-computed, Measurement
  7. Yıl: 2021
  8. Dil: Türkçe
  9. Üniversite: Fırat Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Ağız, Diş ve Çene Cerrahisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu tez çalışmasında mezbahaneden elde ettiğimiz taze sığır kostası üzerinde radyografi (bilgisayarlı tomografi –BT ve konik ışınlı bilgisayarlı tomografi-KIBT) çekerek kemik yoğunluğunu değerlendirmeyi ve elde ettiğimiz verileri mekanik ve manyetik stabilite ölçüm metodları ile karşılaştırmayı amaçladık. Kostalara toplamda 20 adet 4,1 mm çapında 10 mm uzunluğunda dental implant yerleştirildi. İmplant yerleştirmeden önce pilot frezle 10 mm uzunluğunda implant yerleri belirlendi ve bu bölgelerin 4,1 mm genişliğinde 10 mm uzunluğundaki kemik alanının yoğunluğu BT ve KIBT ile HU (Hounsfield Unit) birimlerinde ölçümleri yapıldı. Daha sonra standart frezleme protokolü sonrası implant yuvaları oluşturuldu ve fizyodispenser eşliğinde implantlar yerleştirildi. Primer stabilite mekanik ölçümleri olan yerleştirme ve söküm torkları sayısal değerler olarak kaydedildi. Ardından osstell cihazı ile RFA değerleri ölçüldü. İstatiksel olarak HU değerleri, mekanik ve manyetik primer stabilite ölçümleri arasındaki korelasyon değerlendirildi. Sonuç olarak, taze sığır kostasında konik ışınlı bilgisayarlı tomografi ve tıbbi bilgisayarlı tomografinin kemik yoğunluğu ölçümü arasındaki ilişkiyi değerlendirdik ve istatiksel olarak aralarında anlamlı bir ilişki bulamadık.

Özet (Çeviri)

In this thesis, we aimed to evaluate the bone density by radiography (computerized tomography-CT and cone-beam computed tomography-CBCT) on the fresh beef ribs we obtained from the slaughterhouse and to compare the data we obtained with mechanical and magnetic stability measurement methods. A total of 20 dental implants with a diameter of 4.1 mm and a length of 10 mm were placed on the ribs. Before placing the implant, 10 mm long implant sites were determined with a pilot drill, and the density of the 4.1 mm wide 10 mm long bone area of these regions was measured in HU (Hounsfield Unit) units with CT and CBCT. Then, after the standard milling protocol, the implant sockets were created and the implants were placed with a physiodispenser. Insertion and removal torques, which are mechanical measurements of primary stability, were recorded as numerical values. Then, RFA values were measured with an osstell device. Statistically, the correlation between HU values and mechanical and magnetic primary stability measurements was evaluated. In conclusion, we evaluated the relationship between cone beam computed tomography and medical computed tomography bone density measurement in fresh beef ribs, and we could not find a statistically significant relationship between them.

Benzer Tezler

  1. Statik elektrikle yüklenmiş sıvı ilacın pamuk ilaçlamasında etkinliğinin belirlenmesi üzerinde bir araştırma

    Başlık çevirisi yok

    ALİ BAYAT

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    Çukurova Üniversitesi

    Tarımsal Mekanizasyon Ana Bilim Dalı

    Yükleniyor...

  2. Travmatik erkek paraplojelere yüksek frekanslı TENS

    Başlık çevirisi yok

    SEMA ÖZTÜRK

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Gazi Üniversitesi

    Kazalarda Acil Yardım ve Rehabilitasyon Ana Bilim Dalı

    Yükleniyor...

  3. Hemodiyalize bağımlı kronik böbrek hastalarında gonadotropik hormonlar ile östrojen ve testosteron düzeylerinin araştırılması

    Başlık çevirisi yok

    HANDAN İLGÜNŞATIROĞLU

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1987

    Cumhuriyet Üniversitesi

    Fizyoloji Ana Bilim Dalı

    Yükleniyor...

  4. Uluslararası Kriminal Polis Örgütü-İnterpol'ün örgütsel yapısı ve işleyişi

    Başlık çevirisi yok

    SAADETTİN BORA

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Gazi Üniversitesi

    Kamu Yönetimi Ana Bilim Dalı

    Yükleniyor...

  5. Kemalpaşa etlik piliç işletmelerinin teknik ve ekonomik yönden incelenmesi

    Başlık çevirisi yok

    HAYRİ TUNA YÜKSELEN

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    Ege Üniversitesi

    Zootekni Ana Bilim Dalı

    Yükleniyor...