Özet

Sıvı akışlı pencere sistemleri, pencere camları arasından geçen sıvı dolaşımı ile iç ortamın ısı kazanç veya kayıpları için kullanılmaktadır. Faz değiştiren malzemelerin ısıl enerji depolamada kullanımı tüm güneş enerjisi sistemlerinde olduğu gibi sıvı akışlı pencere sistemleri ile de mümkündür. Tez çalışması kapsamında yaklaşık sıfır enerjili binalar yolunda sıvı akışlı pencere sistemleri ve gizli ısıl enerji depolama sistemleri bir araya getirilerek deneysel ve sayısal olarak incelenmesi amaçlanmıştır. Şebeke suyu destekli ve faz değiştiren malzeme içeren ısıl enerji depolama tanklı sıvı akışlı pencere sistemi kabinleri ile normal pencerelere sahip kabinlerin ısıtma soğutma enerji tüketimleri kıyaslanmıştır. Sıvı akışlı pencerelerin ve ısıl enerji depolama tanklarının sayısal benzetimi yapılmıştır. Yaz mevsiminde, günlük kullanım suyu ön ısıtması için; sonbahar ve kış mevsimlerinde ise dolaşımdaki suyun sıcaklığının gece saatlerinde istenilen değerlerde kalması için hacmi 5.675 litre (%42 su, %46 RT28 HC-RT18 HC, %12 RT35 HC-RT22 HC) olan ısıl enerji depolama tankı ısı değiştirgeci olarak kullanılmıştır. Yaz mevsiminde 0,3 m2 pencere yüzey alanına sahip sıvı akışlı pencere ile 6 saatte 2916 kJ enerjinin depolanabileceğini sonucuna ulaşılmıştır. Isıl enerji depolama tankındaki erime-katılaşma işleminin görselleştirilmesi sayısal çalışma ile elde edilmiştir. Bu esnada sıvı akışlı pencere kabini enerji tüketiminin normal pencere kabini enerji tüketimine oranı %84'e kadar düşmüştür. Şebeke suyu kaynaklı sıvı akışlı pencere için tüketim oranı %33'e kadar düşmüştür. Sonbahar mevsiminde ısıl enerji depolama tankına sahip sıvı akışlı pencere kabini ile normal pencere kabini ısıtma sistemleri için gerekli enerji tüketim oranlarının, gündüz depolanan ısı kullanılarak gece saatlerinde %7'ye kadar düştüğü sonucuna ulaşılmıştır. Aynı mevsim gündüz ölçümlerinde soğutma sistemleri için bu oran en fazla %88 olmuştur. Tüketim oranı şebeke suyu destekli sıvı akışlı pencere için gündüz %39'dan, gece %77'den daha az bulunmuştur. Kış mevsiminde ısıl enerji depolama tankına sahip sıvı akışlı pencere kabini ile normal pencere kabini ısıtma sistemleri için gerekli enerji tüketim oranlarının, gündüz depolanan ısı kullanılarak gece saatlerinde %45'e kadar düştüğü sonucuna ulaşılmıştır. Aynı mevsim gündüz ölçümlerinde soğutma sistemleri için bu oran en fazla %60 olmuştur. Tüketim oranı şebeke suyu destekli sıvı akışlı pencere için gündüz %53'ten az, gece %83'ten daha fazla bulunmuştur. Sonuç olarak, sıvı akışlı pencere sistemlerinin Türkiye ikliminde enerji verimliliğine sahip olduğu, ısıl enerji depolama tankı ile sıvı akışlı pencere sistemlerinin kullanılabilirliği deneysel olarak ortaya konmuştur. Sayısal çalışma sonuçları deneysel çalışmalarla doğrulamıştır, sayısal yöntemlerin farklı varyasyonlar için kullanılabilirliği ortaya konmuştur.

Özet (Çeviri)

Liquid flow window systems are used for the heat gain or loss of the indoor environment with the circulation of liquid passing between the window glazing. The use of phase change materials in thermal energy storage is possible with Liquid flow window systems as in all solar energy systems. Within the scope of the thesis, it is aimed to experimentally and numerically investigate liquid flow window systems and latent thermal energy storage systems on the road to nearly zero energy buildings. The heating and cooling energy consumptions of the liquid flow window system cabinets includes phase change materials in thermal energy storage tank and domestic water supported are compared with cabinet has normal window. Numerical simulation of liquid flow windows and thermal energy storage tanks were made. In summer, for daily domestic water preheating; In autumn and winter seasons, a thermal energy storage tank with a volume of 5.675 liters (42% water, 46% RT28 HC-RT18 HC, 12% RT35 HC-RT22 HC) was used as a heat exchanger to keep the temperature of the circulating water at the desired values at night.. It has been concluded that 2916 kJ of energy can be stored in 6 hours with a liquid flow window with a window surface area of 0.3 m2 in summer. The visualization of the melting-solidification process in the thermal energy storage tank was obtained by numerical study. Meanwhile, the ratio of liquid flow window cabinet energy consumption to normal window cabinet energy consumption decreased to 84%. The consumption rate for the water flow window sourced from the mains water has decreased to 33%. It has been concluded that the required energy consumption rates for the liquid flow window cabinet and normal window cabinet heating systems in the autumn season decreased down to 7% at night using the stored heat during the day. In the same season, this rate was at most 88% for cooling systems in daytime measurements. The consumption rate was found to be less than 39% during the day and less than 77% at night for the domestic water supported liquid flow window. It has been concluded that the required energy consumption rates for the liquid flow window cabinet with thermal energy storage tank and normal window cabinet heating systems in the winter season decrease down to 45% at night using the stored heat during the day. In the same season, this rate was at most 60% for cooling systems in daytime measurements. The consumption rate was found to be less than 53% during the day and more than 83% at night for the domestic water supported liquid flow window. As a result, it has been experimentally demonstrated that the liquid flow window systems have energy efficiency in the Turkish climate, and the usability of the thermal energy storage tank and liquid flow window systems. Numerical studies have confirmed the results with experimental studies, and the usability of numerical methods for different variations has been demonstrated.

Benzer Tezler

  1. Diesel motorları yakıt püskürtme sistemlerinin dinamik simülasyonu

    Başlık çevirisi yok

    İRFAN KARAGÖZ

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Uludağ Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  2. Karıştırıcılar ve karıştırma kabındaki akım olaylarının incelenmesi

    Başlık çevirisi yok

    NADİR İLTEN

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Uludağ Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  3. Çiğit ve ayçiçek yağlarının doğal antioksidan içerikleri ile bu yağların stabilitelerinin arttırılmaları üzerinde araştırmalar

    Başlık çevirisi yok

    ALİ KEMAL YALNIZ

    Doktora

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Gıda Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  4. Statik elektrikle yüklenmiş sıvı ilacın pamuk ilaçlamasında etkinliğinin belirlenmesi üzerinde bir araştırma

    Başlık çevirisi yok

    ALİ BAYAT

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    Çukurova Üniversitesi

    Tarımsal Mekanizasyon Ana Bilim Dalı

    Yükleniyor...

  5. Batı tesirine kadar Osmanlı mimarisinde estetik kriterler

    Başlık çevirisi yok

    LEYLA BAYDAR

    Doktora

    Türkçe

    Türkçe

    1986

    Gazi Üniversitesi

    Mimarlık Ana Bilim Dalı

    Yükleniyor...