İnternal radyonüklid tedavisinde organ doz hesaplama parametrelerinin optimizasyonu

Optimization of organ dose calculation parameters in internal radionuclide treatment

  1. Tez No: 697699
  2. Yazar: BİLAL KOVAN
  3. Danışmanlar: PROF. DR. BAYRAM DEMİR, PROF. DR. CÜNEYT TÜRKMEN
  4. Tez Türü: Doktora
  5. Konular: Fizik ve Fizik Mühendisliği, Radyoloji ve Nükleer Tıp, Physics and Physics Engineering, Radiology and Nuclear Medicine
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2021
  8. Dil: Türkçe
  9. Üniversite: İstanbul Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Fizik Ana Bilim Dalı
  12. Bilim Dalı: Nükleer Fizik Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Nükleer tıbbın gelişimi ile uygulanan tedaviler ve tedavilerin etkinliği gün geçtikçe artarak devam etmektedir. Yaygın olarak uygulanan sistemik tedavilerde amaç, damar içine verilen radyofarmasötiğin dolaşım sistemi yardımı ile hedef dokularda birikimini sağlamaktadır. Radyofarmasötik, hedef dokuların yanı sıra radyofarmasötiğin tutulum ve atılım mekanizmasına bağlı olarak istenmeyen organlarda da tutulum göstermektedir. Radyofarmasötiğin tutulum ve atılım mekanizmalarına bağlı olarak tedaviyi sınırlayıcı kritik organ dozlarına ulaşması durumunda tedavinin sonlandırılması gerekmektedir. Organlar ve lezyonların absorbe ettiği radyasyon dozunun doğru hesaplanması, hastalığın etkin bir biçimde tedavi edilirken hastanın zarar görmemesi açısından önem taşımaktadır. Kümülatif aktivitenin tespiti kantitatif yöntemlerle yapıldığından ötürü birçok değişkene bağlı olarak hesaplama sonuçlarında önemli sapmalar oluşabilmektedir. Dozimetrik hesaplamalar yapılırken ölçümlerin yapıldığı cihazların kararlılığı ve görüntüleme protokolleri oluşturulurken hata paylarının en düşük oranda tutulması gerekmektedir. Bu tez çalışmasında gama kamerada 10 ay süre ile sabit parametrelerde ardışık ölçümler alınarak cihaz kararlılığı değerlendirildi. Organ aktivitelerinin tespitinde kullanılan Standart Aktivite Dönüşüm Faktörü (SADF) hesaplamasında kullanılmak üzere insan vücudunu taklit etmesi için insan benzeri fantom ve kilolu insan vücudunu taklit etmesi için kilolu insan benzeri fantom imal edildi. Sabit hacimli aktivite ile havada, insan benzeri fantom ve kilolu insan benzeri fantom ile SADF tespit edildi. Daha sonra aynı aktivite ile farklı hacimlerde su ile sulandırılarak SADF tespit edildi. Elde edilen SADF sonuçları karşılaştırılarak değerlendirildi. Lezyon dozimetri hesaplamalarında kullanılan lezyon hacminin doğru tespiti için NEMA PET fantomu kullanılarak farklı görüntüleme parametrelerinde ölçümler alındı. Farklı parametreler kullanılarak elde edilen veriler değerlendirildi. 10 ay süre ile sabit parametrelerde ardışık ölçümler alınarak elde edilen veriler değerlendirildiğinde %2,88'lik bir sapma tespit edildi. Tek pik azalım düzeltmesi ve saçılım düzeltmesi yapılmış görüntülerde insan benzeri fantom ve kilolu insan benzeri fantom sonuçları benzer olarak saptandı., vial/insan benzeri fantom %+23 fark olarak, sulandırılmış kaynak/insan benzeri fantom %+16 fark tespit edildi. NEMA PET fantomu kullanılarak 37 mm çaplı kürecik ile alınan verilerde %40 eşik değer kullanılarak elde edilen hacimler gerçekten daha küçük hesaplanmaktadır. Tarama süresi projeksiyon başına 20 sn'den 10 sn'ye düşürüldüğünde sayım etkinliğinde %1 oranında değişim saptandı. Projeksiyon sayısı düşürüldüğünde sayım etkinliğindeki sapma %3,6'ya çıktığı saptandı. Sonuç olarak; hata oranlarının minimum düzeyde tutulması için SADF saptanırken insan benzeri fantom kullanılması gerekmektedir

Özet (Çeviri)

In nuclear medicine, the treatments applied and the effectiveness of the treatments continue to increase day by day. The general aim in systemic treatments is that the intravenously administered radiopharmaceutical reaches the target tissue through the circulatory system and accumulates there. In addition to the target tissue, radiopharmaceuticals can actually cause unwanted organ irradiation in the areas of physiological uptake and excretion pathway. If this effect is in critical organs, this situation can be limiting or terminating the treatment. Accurate calculation of the radiation dose absorbed by organs and lesions are important in terms of not harming the patient while treating the disease effectively. The determination of cumulative activity depends on many variables, as it is done by quantitative methods and significant deviations may occur in the calculation results. While performing dosimetric calculations, the stability of the devices where the measurements are made should be high and the margin of error of imaging protocols should be kept at the lowest rate. In this study, device stability was evaluated for 10 months by taking consecutive measurements at fixed parameters in a gamma camera. A human-like phantom was produced to imitate the standard and overweight human body to be used in the calculation of the Standard Activity Conversion Factor (SACF) used in the determination of organ activities. SACF detected in air, human-like phantom and overweight human-like phantom with constant volume activity, respectively. Then, SACF was determined by diluting the same amount activity in different volumes. SACF results were compared and evaluated. Measurements were performed in different imaging parameters by using the NEMA PET phantom, which is used in lesion dosimetry calculations and provides an accurate determination of the lesion volume. The data obtained with different parameters were evaluated. A deviation of 2.88% was detected in consecutive measurements performed with constant parameters for 10 months. Standard and overweight human-like phantom results were found to be similar in images with single peak attenuation correction and scatter correction. When compare the vial/human-like phantom and the diluted source/human-like phantom, the measurements in the human-like phantom were 23% and 16% higher, respectively. The volumes obtained by using 40% threshold value in the data measured with 37 mm diameter bead using NEMA PET phantom are calculated smaller than the actual diameter. When the scanning time was reduced from 20 seconds to 10 seconds per projection, a 1% change in counting efficiency was detected. When the number of projections was reduced, the deviation in counting efficiency increased to 3.6%. As a result; in order to keep error rates in minimum, a human-like phantom should be used when determining the SACF.

Benzer Tezler

  1. Karaciğer tümörlerinin tedavisinde uygulanacak Y-90 mikrokürelerin aktivite miktarlarının hastaya özgü modelleme ile belirlenmesi için yöntem geliştirilmesi ve yöntemin standardize edilmesi

    Development of a method for determination of activity quantities of Y-90 microspheres to be administered in treatment of liver tumors by patient-specific modeling and standardization of the method

    FERYAL ÇAKIR

    Doktora

    Türkçe

    Türkçe

    2019

    Fizik ve Fizik MühendisliğiHacettepe Üniversitesi

    Biyomühendislik Ana Bilim Dalı

    PROF. DR. AYŞE KEVSER ÖZDEN

    PROF. DR. MURAT FANİ BOZKURT

  2. Radyonüklid tedavi lezyon dozimetresinde hacim belirleme parametrelerinin optimizasyonu

    Optimization of volume determination parameters in radionuclide therapy lesion dosimetry

    EDA MUTLU

    Doktora

    Türkçe

    Türkçe

    2024

    Fizik ve Fizik Mühendisliğiİstanbul Üniversitesi

    Fizik Ana Bilim Dalı

    PROF. DR. BAYRAM DEMİR

    DR. ÖĞR. ÜYESİ BİLAL KOVAN

  3. Pet radyofarmasötiklerinin radyonüklid dozimetrideki yeri ve önemi

    The place and importance of pet radiopharmaceuticals in radionuclide dosimetry

    NAMİ YEYİN

    Doktora

    Türkçe

    Türkçe

    2023

    Fizik ve Fizik Mühendisliğiİstanbul Üniversitesi-Cerrahpaşa

    Nükleer Tıp Ana Bilim Dalı

    PROF. DR. MUSTAFA DEMİR

  4. Kanser hastalarında kemik metastaz gelişim paterni ve iskelet ilişkili olayların değerlendirilmesi

    Evaluation of bone metastasis development pattern and skeleton related events in cancer patients

    ONUR TANGUR

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2023

    İç HastalıklarıSağlık Bakanlığı

    İç Hastalıkları Ana Bilim Dalı

    DOÇ. DR. FATİH İNCİ

  5. Tc99m-MAA sintigrafisinde SPECT/BT görüntülerine uygulanan foton atenüasyon ve saçılım düzeltmelerinin (AC ve SC) y-90 dozimetrisi üzerindeki etkilerinin değerlendirilmesi

    Evaluation of Effects of Scatter and Attenuation Correction on Internal Dosimetry Calculation for Radionuclide Therapy of Liver Tumor

    ÖZGÜR TAYLAN AKDAĞ

    Yüksek Lisans

    Türkçe

    Türkçe

    2020

    Radyoloji ve Nükleer Tıpİstanbul Üniversitesi-Cerrahpaşa

    Nükleer Tıp Ana Bilim Dalı

    PROF. DR. MUSTAFA DEMİR